KEY INFORMATION YOU SHOULD

KNOW:

• 260 PSI Air Compressor Inflator

• 12 Volt DC Portable Power Supply

• 450 Amp Instant Starting Power

• Portable, Cordless, Rechargeable

IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR

PURCHASE CALL TOLL FREE (866) 584-5504.  IN MOST

CASES A SERVICE REPRESENTATIVE CAN RESOLVE YOUR

PROBLEM OVER THE PHONE

....

12V POWER SUPPLY

Jump-Start System

BEFORE RETURNING THIS PRODUCT FOR ANY REASON,

PLEASE CALL TOLL FREE (866) 584-5504

2 YEAR LIMITED WARRANTY PROGRAM

This limited warranty program is the only one that applies to this product, and it sets forth all

the responsibilities of Vector Manufacturing, Ltd., regarding this product. There is no other war-

ranty, other than those described herein.
This Vector Manufacturing, Ltd. product is warranted, to the original purchaser only, to be free of

defects in materials and workmanship for two years from the date of purchase without addi-

tional charge. The warranty does not extend to subsequent purchasers or users. Vector

Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail

purchase price of the product under any circumstances. Incidental and consequential damages

are specifically excluded from coverage under this warranty.
This product is not intended for commercial use. This warranty does not apply to accessories or

damage to units from misuse or incorrect installation. Misuse includes wiring or connecting to

improper polarity power sources.

RETURN/REPAIR POLICY:

Defective products, other than accessories, may be returned postage

prepaid to Vector Manufacturing. Any defective product, other than accessories, that is

returned to Vector Manufacturing within 30 days of the date of purchase will be replaced free

of charge. If such a product is returned more than 30 days but less than two years from the

purchase date, Vector Manufacturing will repair the unit or, at its option, replace it free of

charge.
If the unit is repaired, new or reconditioned replacement parts may be used, at Vector

Manufacturing’s option. A unit may be replaced with a new or reconditioned unit of the same

or comparable design. The repaired or replaced unit will then be warranted under the terms of

the remainder of the warranty period. The customer is responsible for the shipping charges on

all returned items after 30 days. During the warranty period, Vector Manufacturing, Ltd. will be

responsible for the return shipping charges.

LIMITATIONS:

This warranty does not cover accessories, bulbs, fuses and batteries, defects result-

ing from normal wear and tear (including chips, scratches, abrasions, discoloration or fading

due to usage or exposure to sunlight), accidents, damage during shipping to our service facil-

ity, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions

for care and maintenance, fire, flood and Acts of God.
If your problem is not covered by this warranty, call our Technical Support Department at (954)

584-4446 or Toll Free at (866) 584-5504 for general repair information and charges if appli-

cable. You may also contact us through our website at www.vectormfg.com.

STATE LAW RIGHTS:

This warranty gives you specific legal rights. Some states do not allow limita-

tions on how long an implied warranty lasts or the exclusion or limitation of incidental or con-

sequential damages, so the exclusions or limitations stated herein may not apply. This warranty

gives the purchaser specific legal rights; other rights, which vary from state to state, may apply.

TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT:

Contact Vector Manufacturing Technical

Support by telephone, fax or mail. We suggest that you keep the original packaging in case

you need to ship the unit. When returning a product, include your name, address, phone num-

ber, dated sales receipt (or copy) and a description of the reason for return and product serial

number. After repairing or replacing the unit, we will make everyeffort to return it to you with-

in four weeks.

WARRANTY ACTIVATION:

Please complete Warranty Activation Card and mail to Vector

Manufacturing. Enter VEC012POB as Model and “Jump-Start System” as Product Type. All

Vector Manufacturing, Ltd. products must be registered within 10 days of purchase to activate

this warranty. Mail the completed registration form, along with a copy of the original sales

receipt to:

ATTN.: CUSTOMER SERVICE / VECTOR MANUFACTURING, Ltd.

4140 SW 28th Way, Ft. Lauderdale, FL 33312 

PH: 954-584-4446 • TOLL FREE: 866-584-5504 • Fax: 954-584-5556. 

You may also contact us at our web site www.vectormfg.com.

WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.

DS032904

Summary of Contents for VEC012POB

Page 1: ... DC Portable Power Supply 450 Amp Instant Starting Power Portable Cordless Rechargeable IF YOU SHOULD EXPERIENCE A PROBLEM WITH YOUR PURCHASE CALL TOLL FREE 866 584 5504 IN MOST CASES A SERVICE REPRESENTATIVE CAN RESOLVE YOUR PROBLEM OVER THE PHONE 12V POWER SUPPLY Jump Start System ...

Page 2: ...use short circuits or react with battery acid 10 Always disconnect the negative black jumper cable first followed by the positive red jumper cable except for positive ground systems 11 Never allow red and black clamps to touch each other or another common metal conductor This could cause damage to the unit and or create sparking explosion hazard Always store battery clamps in built in holsters whe...

Page 3: ...e adapter The adapter barrel connector attaches to the recharge port on the top panel of the jump starter A built in 12 volt appliance outlet and the appropriate DC DC charging adapter cord is used to recharge the battery from another 12 volt DC source When pressed the charge status pushbutton will show the battery power level status on the battery status display from low to full The green LED ful...

Page 4: ...battery 4 Vehicles that have on board computerized systems may be damaged if vehicle battery is jump started Before jump starting this type of vehicle read the vehicle owner s manual to confirm that external starting assistance is advised 5 Excessive engine cranking can damage the vehicle s starter motor If the engine fails to start after the recommended number of attempts discontinue jump start p...

Page 5: ... switch to ON if the Reverse Polarity LED is lit or alarm sounds If inadvertent reverse polarity occurs the alarm will sound and the red LED will light Disconnect the black clamp negative clamp first then the red clamp Reconnect the polarity properly and then turn the key To recap CONNECT Red clamp first then black clamp DISCONNECT Black clamp first then red clamp 1 Turn OFF vehicle ignition and a...

Page 6: ...er exceed recommended pressures Bursting articles can cause serious injury Always check pressure with the pressure gauge Never leave compressor unattended while in use Allow unit to cool after 10 minutes of continuous operation 3 After initial 48 hour charge charge this device for at least 14 16 hours or until the green FULL indicator lights Charge at least once a month when not in use 4 When char...

Page 7: ... volt DC AC Charging Adapter 120 volt AC 700mA 12 volt DC Output 6 2 Tire Inflation or Products with a Valve Stem 1 Place connector chuck on valve stem 2 Push connector toward valve stem and close thumb latch 3 Make sure connector is pushed onto valve stem as far as possible before closing thumb latch 4 Check pressure with the pressure gauge 5 When desired pressure is reached turn Off compressor p...