background image

 1 

Battery Chargers 

Sealed or Valve Regulated 

Lead Acid Batteries 

Model: PSC-124000A 

 

CAUTION:  
TO PREVENT THE RISK OF ELECTRIC SHOCK, DO 
NOT REMOVE COVER NO USER FRIENDLY PARTS 

CAUTION  
THIS UNIT SHOULD NOT BE USED IN OUTDOOR APPLICATIONS.  
EXPOSURE TO MOISTURE MAY RESULT IN FIRE OR SHOCK HAZARD 

OPERATING PROCEDURES AND  SAFETY INSTRUCTIONS 

Summary of Contents for PSC-124000A

Page 1: ...odel PSC 124000A CAUTION TO PREVENT THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER NO USER FRIENDLY PARTS CAUTION THIS UNIT SHOULD NOT BE USED IN OUTDOOR APPLICATIONS EXPOSURE TO MOISTURE MAY RESULT IN FIRE OR SHOCK HAZARD OPERATING PROCEDURES AND SAFETY INSTRUCTIONS ...

Page 2: ...aintenance free rechargeable batteries Attempting to charge other types of batteries may result in personal injury and battery damage The heat sink and enclosure will become hot during the charge cycle DO NOT TOUCH Connect or disconnect the output connectors only when the unit is disconnected from AC power or arcing and burning may result due to the possible presence of explosive gases DANGER Neve...

Page 3: ...al with a sign or the color red and identify the negative terminal with a sign or the color black Connect the red insu lated output clip to the positive battery terminal and connect the black insulated output clip to the negative battery terminal If the charger is provided with a polarized connector make sure your bat tery connector is wired to match the output connector The input voltage setting ...

Page 4: ...use the charger switches into float charge mode too early relative to capacity Leave the battery to the charger for several hours to finish charging in the float charge mode TROUBLESHOOTING NO INDICATOR LIGHT If the indicator light is dark check the fuse and replace if necessary If the fuse is good check the voltage switch setting and input power is the receptacle controlled by a light switch If a...

Page 5: ...cleaners directly onto the charger or immerse unit in water BATTERY CHARGER SPECIFICATIONS Operating temperature 0 to 35 C 32 to 95 F Storage temperature 40 to 80 C 40 to 176 F Dimensions H 3 40 8 6cm x W 6 65 16 9cm x D 5 30 13 5cm Weight About 7 4lbs 3 4kg Input fuse type 5x20mm fast acting miniature glass fuse UL CSA approved Power Requirements 115 230 V 50 60 Hz 98 A RMS OUTPUT RATING 25 C Cha...

Page 6: ...6 Power Sonic Corporation 7550 Panasonic Way San Diego CA 92154 Tel 619 661 2020 Fax 619 661 3650 E Mail quality assurance power sonic com ...