IF USING INTUMESCENT KIT R97-XX, REFER TO INSTRUCTIONS
WITH KIT AS INSTALLATION DEPTHS WILL INCREASE
PLEASE READ FITTING INSTRUCTIONS THOROUGHLY
BEFORE INSTALLATION
IMPORTANT NOTICE - FOR FIRE DOOR INSTALLATIONS
REFER TO ITEM 1 IN FITTING INSTRUCTIONS
•
UKCA marked
• CE marked and adjustable to conform to power size 3 of Controlled Door Closing
Device. BS EN1154: 1997 (Test door 60kg/132lbs).
• 1 Hour Fire Test BS EN1634-1: 2000.
• Adjustable speed control.
• Adjustable power latching action.
•
1 1/2 Pairs of hinges should be used in conjunction with this closer on all doors.
• Suitable for doors opening to a maximum of 105°. A door stop should be fitted.
• Maximum door weight 80kg/175lbs, width 950mm/38”.
• Suitable for latched and unlatched doors.
• Should
NOT
be used with rising butt hinges.
• For use with concealed hinges contact our Customer Service Team - details on
the back of this leaflet.