PDU for VFI ICR IoT 6-10kVA 

Installation and user manual

Service and support: 

Call your local service representative 

Summary of Contents for 10133013

Page 1: ...PDU for VFI ICR IoT 6 10kVA Installation and user manual Service and support Call your local service representative...

Page 2: ...ithin 0 to 50 C free of conductive contaminant Special symbols RISK OF ELECTRIC SHOCK Observe the warning associated with the risk of electric shock symbol Important instructions that must always be f...

Page 3: ...vercurrent protection devices shall be provided by others for permanently connected AC input Normal AC Bypass AC and AC output circuits Check that the indications on the rating label correspond with y...

Page 4: ...king and Inspecting 4 3 2 Checking the accessory kit 4 3 3 Mechanical Installation 5 3 4 Power cables connection 8 4 Service operation 12 4 1 How to switch system to BYPASS mode 12 4 2 How to disconne...

Page 5: ...tal protection Products are developed according to an eco design approach Substances This product does not contain CFCs HCFCs or asbestos Packing To improve waste treatment and facilitate recycling se...

Page 6: ...Output socket group 2 programmable 3 Output Breaker Optional default is no 4 Maintenance bypass switch 5 Input Output terminal Connected to power and load 6 Input switch 7 Input Output terminal Connec...

Page 7: ...t group programmable 2 Maintenance bypass switch 3 Input Output terminal Connected to power and load 4 Input switch 5 RJ45 port including EBM Detect and RT model MBP COMM 6 Input Output terminal Conne...

Page 8: ...file a claim for shipping damage If you discover damage after acceptance file a claim for concealed damage Note Discard or recycle the packaging in a responsible manner or store it for future use Pack...

Page 9: ...and MBP detection cable to the MBP before installing 1 Remove the cover of terminal blocks and connect cables for UPS Input Output to terminal blocks refer to the indication on rear panel MBP 1 1 MBP...

Page 10: ...figured length of cables for UPS Input Output and MBP detection cable Left position Top position 2 Install Ear bracket to MBP then assemble MBP to UPS by M4 screws Below pictures are examples of Left...

Page 11: ...7 Position 1 Rear of rack Position 2 Front of rack 1 Install Rail kit to rack cabinet by M5 screws and washers...

Page 12: ...lips 3 4 Power cables connection This chapter introduces how to connect MBP to UPS and connect AC IN OUT cable to MBP 3 4 1 Wiring for MBP connecting to UPS Before power cables connected Insert MBP de...

Page 13: ...d cable minimum cross sectional area Model MBP 1 1 MBP 3 1 With RT 6K S 1 1 With RT 10K S 1 1 With RT 10K S 3 1 Protective earthing conductor 10mm2 10mm2 10mm2 Input L N cable 6mm2 10mm2 10mm2 Output...

Page 14: ...nection must be carried out by qualified electrical personnel Before carrying out any connection check that the upstream protection devices Normal AC source are open O Off 1 Remove the cover of termin...

Page 15: ...w default is setting with 3 1 mode 1 1 mode Short MBP input terminal L1 L2 L3 with busbar then connect AC cable 3 1 mode For cables well fixed it is recommended to tie these cables to the convex of re...

Page 16: ...nce switch cover the UPS will turn to bypass mode automatically 2 Rotate the maintenance switch to BYPASS position Note For an unconscious operation it is recommended to install back the Maintenance s...

Page 17: ...ent Don t let the MBP suffer any strong stress during rotation position 4 3 How to switch system to NORMAL mode Clarify your UPS is already complete service or replacement installation 1 Connect cable...

Page 18: ...14 4 4 How to detect the EBM to this system This is to connect the configured EBM to a system UPS MBP with EBM detection cable as below...

Page 19: ...t Once it is set as auto off on that output power will turn off when battery capacity below 50 in battery mode and outlet socket group Programmable will turn on again when charger begins to work 3 Env...