GENERATOR USE AND MAINTENANCE MANUAL

HG2500 

E3200 
E4000 
E5000 
E6900 

Summary of Contents for E5000

Page 1: ...1 GENERATOR USE AND MAINTENANCE MANUAL HG2500 E3200 E4000 E5000 E6900 ...

Page 2: ...e engine due to restricted air flow The generator must be operated on a level surface The generator should be anchoured securely if there is a risk of movement i e units with unbraked chassis frames should be chocked Do not replenish fuel or oil while the generator is running Do not allow unauthorised persons or children in the work area even after the machine has stopped there is a risk of severe...

Page 3: ...3 A B C D ...

Page 4: ...required and is either on the frame or on the electric panel NOISE LEVEL LABEL REGISTERED NUMBER This certifies that the equipment will not exceed the This label indicates the name registered number and the relevant figure shown on the label The label is located characteristics of the machine The label is located on the tubular frame or on the front panel of the machine on the casing of the machin...

Page 5: ...companies Cables plugs sockets and cable couplers should be suitable for the environmental conditions Cables should be preferably flexible and contain a metallic screen Plugs and sockets should conform to BS4343 If metallic screen cable is not available a cable with high abraison resistance with a separate protective conductor should be utilised Cables should be as short as practicable and routed ...

Page 6: ... generator cannot turn over during transportation Remove all fuel and ensure that acid or fumes do not leak from the battery where applicable Do not overload the transport vehicle Under no circumstances should the generator be started while inside a truck The generator is a heavy item movement is to be carried out under the guidelines of the Health Safety At Work Act Lifting eyes where fitted are ...

Page 7: ... VOLT STATOR MUST BE ROTOR MUST BE BATTERY OBSERVING THE CORRECT POLARITY REPLACED REPLACED DOES THE MACHINE NOW GIVE ABOUT THE RIGHT VOLTAGE OUTPUT YES REPLACE A V R BOARD NO IS THE VOLTAGE EQUAL FOR EACH PHASE YES NO PROBABLE ROTOR FAULT PROBABLE STATOR FAULT DISMANTLE AND CHECK DISMANTLE AND CHECK FOR RESISTACES AND DIODES BURNT OR BROKEN WIRES REPLACE WHERE NECESSARY REPLACE WHERE NECESSARY NO...

Page 8: ...ar NP22 4EF Telephone 44 01495 713300 Fax 44 01495 718766 e mail info pramac co uk website www pramac com No Modifications Are Allowed To This Document Unless Prior Approval Has Been Received And Approved By The Technical Department cod G005471 01 2005 REV 01 ...