USER’S MANUAL FOR 

PRECISION POWER DESKTOP PRO UPS 

MODEL NUMBER:  PR1236DT-B

WARNING

  
Review the following important safety warnings to avoid bodily injury or 
damage to equipment during installation or operation of the device.  Read 
ALL instructions before attempting to install or operate this device.

This device is intended for indoor use only.  To prevent the risk of fire 
or electrical shock, install in dry location free from damp or wet 
environment, or potentially damp or wet environment.  

Adhere to all acceptable operating environment limitations as listed 
to prevent the risk of fire or electrical shock (see user specifications 
within User’s Manual)

Risk of fire or explosion if improper battery is installed and attempted 
to operate within this device.  Device is rated and approved for use 
with standard sealed lead acid battery rated at 12Vdc 7Ah-8Ah.  
Follow User Manual instructions for proper installation of battery.  
Dispose of used batteries in accordance to battery manufacturer 
specifications. 

NO user-replaceable parts within this device except the battery.  Do 
not remove cover unless you are installing, replacing, or servicing 
the battery.

NOTE: 

 The reference to “Desktop Pro” within this User Manual refers to Precision Power 

Model PR1236DT-B and all package accessories as listed below

CONTENTS OF DESKTOP PRO PACKAGE

NOTE:

  Please verify all standard contents are accounted for upon receipt of Desktop Pro 

UPS.

STANDARD: 

 (1) Desktop Pro UPS; (1) Cable Guide; (1) AC Power Cord; (3) Cable Ties; 

(1) 7-Pin Connector; (1) User’s Manual; (1) Wall-Mount Installation Template

DESKTOP PRO INTRODUCTION

The Desktop Pro UPS is designed and intended for use as a Desktop or Wall-mountable 
DC UPS for indoor and outdoor 12Vdc Optical Network Terminals (ONT) and Customer 
Premise Equipment (CPE).  The Desktop Pro not only provides constant supply of DC 
power during normal operating conditions, but also offers battery backup power in case of 
electrical power outage when paired with approved standby battery.  

VISUAL INDICATORS AND CONTROL SWITCHES

1

2

3

4

5

6

7

VISUAL INDICATORS

SYSTEM STATUS   Color-Green   Receiving AC power load to operate 

     under normal conditions

DC

   Color-Green   Working off Battery

Mute 

   Color-Yellow   “Flashing”- Audible Alarm Silenced for 

       24 hrs, “Solid”- Audible Alarm silenced 
       until manually enabled again.

Battery

   Color-Red       Service or replace battery, or battery 

      missing

CONTROL SWITCHES

ALARM SILENCE

COLD START

N.I.R.

Disables Audible Alarm Function.  Press and release to 
disable Audible Alarm for 24 hours.  Press and hold for 
15 seconds to disable Audible Alarm indefinitely.  Press 
and hold for another 15 seconds in order to re-enable 
Audible Alarm function.  

Allows Desktop Pro capability to restart and restore 
standby power with new battery or to use reserve 
standby power on existing battery when in AC lin 
power outage for extended time.

Network Interface Reset (N.I.R.) - Allows for DC line 
power reset of Optical Network Terminal.  Press and 
hold for 3 seconds to reset/reboot ONT or CPE device.

1

2

3

4

5

6

7

VISUAL AND AUDIBLE STATUS/ALARM SIGNALS

STATE

VISUAL 

INDICATOR

AUDIBLE 

INDICATOR

DESCRIPTION

NORMAL

ON 

Battery

Replace 

Battery

Battery 

Missing

Low 

Battery

System Status 

Indicator “ON”

DC Indicator 

“ON”

Battery 

Indicator “ON”

Battery 

Indicator “ON”

DC Indicator 

Flashes

System Status 

Indicator “ON”

1/2 second 

indicator every 

15 minutes

1/2 second 

audible 

indicator 4 

times per 

minute

Operating under normal AC line 

power load and conditions.  

AC line power failure or AC cord 

disconnection.  Desktop Pro is 

being supplied with battery power.

Replace faulty or end of life 

battery

Operating on AC line power only 

without available battery backup 

for outage scenario.  When 

battery is removed from unit, 

battery indicator will illuminate 

after 15 seconds.

Battery has reached equal to or 

less than 45% remaining capacity 

on battery discharge

PASS THROUGH AC OUTLET PLUG

AC INPUT POWER CORD CONNECTOR

P

DC OUTPUT/TELEMETRY CONNECTOR

BATTERY DOOR