IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.
Part No...........................................
93034338
Page 1 of 2
With representatives offices in principal cities throughout North America.
Copyright , revision, All Rights Reserved - Printed in U.S.A.
701 Millennium Blvd • Greenville, SC 29607
2018 10/25/18
w
w
w
.p
re
s
c
o
lit
e
.c
o
m
•
P
re
s
c
o
lit
e
T
o
ll
F
re
e
T
e
c
h
n
ic
a
l S
u
p
p
o
rt
1
.8
8
8
.P
R
S
.4
T
E
C
•
H
o
u
rs
: 8
a
m
-
5
p
m
E
T
In
s
tr
u
c
tio
n
S
h
e
e
t
INSTALLATION INSTRUCTIONS
LITEFRAME
®
LF4EM, 4LFEM, LF6EM, 6LFEM, LF8EM & 8LFEM
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND
PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
THE PRODUCT MUST BE INSTALLED BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE
PRODUCT AND THE HAZARDS INVOLVED, IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE.
KEEP THESE INSTALLATION INSTRUCTIONS
FIGURE 3
MODULE CONNECTOR
DETAIL
FIGURE 1
EM REFLECTOR ASSY
MOUNTING DETAIL
1. Install the fixture in the ceiling using the hanger bars (supplied),
or mounting channel or bars (by others) placed in the adjustable
mounting brackets. Mount the fixture in the ceiling so that the
weight of the fixture is supported by the hanger bars, mounting
channel, bar, and/or hanger wires secured to the building
structure.
2. Adjust the fixture so the bottom of the plaster flange opening is
flush with the finished ceiling line and in alignment with adjacent
fixtures. Secure mounting brackets by tightening wing nuts on
either side of the fixture.
3. Determine where the supply wiring conduit will enter the J-Box
and attach it in conformance with the National Electric Code and
local code.
4. Remove J-Box cover plate. Remove appropriate knockout and
assemble the appropriate connector for the supply wire used.
Connect ground wires to green ground leads. Connect white
(common) to white (leads). Connect power supply (line) to black
lead(s) as per the Battery Backup Installation Instructions
included with the fixture. Reinstall J-Box cover.
WARNING: DO NOT pinch wires between J-Box/ballast cover
and J-Box. Consult a qualified electrician for all other
options that require other wiring configurations.
5. Pull electrical cover (1) down through opening in fixture.
(SEE FIG.1).
6. Squeeze two torsion springs (2) together and insert ends into two
brackets (3). Make sure hole in the reflector (4) lines up with the
placement of the EM switch (5). Loosen the nut (6) to adjust the
position of EM Switch (5) in the bracket (7) to line up with
reflector cutout (4) if required.(SEE FIG. 2)
7. Insert connector (8) into module (9) and snap electrical cover (10)
onto module assembly. (SEE FIG 3)
8. Insert tab (11) into bracket. Align screw (12) with hole and
tighten. (SEE FIG. 3)
9. Push trim assembly up towards ceiling until springs draw trim
firmly against ceiling.
1
2
3
5
4
8
9
10
11
12
FIGURE 2
EM SWITCH MOUNTING
DETAIL
5
6
7
CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, MAKE CERTAIN THAT THE POWER
SUPPLY IS OFF BEFORE INSTALLING OR SERVICING THIS FIXTURE!