background image

PRO-TEC

SYSTEM ONE

Trailer Security Systems

“Professional Technology to

Pro-Tec Your Investment”

Photo includes System One Plus pager unit.

Summary of Contents for Automobile Alarm

Page 1: ...PRO TEC SYSTEM ONE Trailer Security Systems Professional Technology to Pro Tec Your Investment Photo includes System One Plus pager unit ...

Page 2: ...Congratulations on your purchase of a state of the art trailer security system This system has been designed to provide years of trouble free operation ...

Page 3: ...s alerting you of a potential problem This device complies with part 12 of FCC rules Operation is subject to the following conditions 1 This device may not cause harmful inter ference and 2 This device must accept any interference received including interference that may cause undesired operation The system requires no specific maintenance Your remote control is powered by a miniature 12 v battery...

Page 4: ...ggle switch n 3 Pin type door switches n 3 Door switch brackets n 1 Seal tite connector n Mounting screws n 3 Crimp connectors n Insurance rebate card n Warranty card n 2 Vinyl Decals Pro Tec System One Plus Package includes All the above plus n Pager and base unit n Manual page button ...

Page 5: ... Point siren down so water does not collect in it n CONTROL UNIT 1 Mount securely inside trailer 2 The higher the control unit is mounted in the trailer the better the transmitter range will be n SWITCHES 1 Mount pin switch 2 Make sure switch bracket is mounted to trailer and properly grounded n OPTIONAL EQUIPMENT 1 Mount pager antenna outside of trailer ...

Page 6: ...ATION 1 Installation of 12 volt full size automo tive battery grounded to trailer and kept charged is needed for proper operation 2 Use 20 gauge wire from door switches to control unit Use separate wire for each door and connect to terminal block marked for that door 3 Connect 12 gauge wire from trailer running lights circuit to terminal block NOTE The control unit is able to handle 20 amp load 4 ...

Page 7: ... wire to control module terminal block connect black wire to trailer ground 7 Connect 12 gauge wire from negative battery terminal to control module terminal block 8 Connect 12 gauge wire from positive battery terminal to control terminal block NOTE When alarm is first powered up the siren will sound Press the remote button 1 twice First time will silence alarm second will shut off alarm Then pres...

Page 8: ...s Button 1 once to silence siren Note Alarm is still armed f Press button 1 again to disarm alarm g Trailer lights will flash at least twice Repeat above sequence to test all doors 4 Setting sensitivity on Shock Sensor a Turn set screw to halfway point b Place 2X4s a few feet in front of the tow vehicle wheels and tow trailer over 2X4s Further adjustment might be necessary according to your enviro...

Page 9: ... sensor or switch along with any other sensors or switches sharing the same zone If the bypassed sensor tries to trigger the system while it is being bypassed the 60 minute bypass period will start over This ensures that a sensor that continuously triggers will remain bypassed Doors are covered by NPC differently If the alarm is triggered by an open door for three full cycles one and one half minu...

Page 10: ... siren is not sounding Press button 1 once Running lights will flash at least twice Trailer is now disarmed and safe to enter 2 If siren is sounding Press button 1 once This will silence the siren and stop the running lights flashing Note Trailer alarm is still armed Press button 1 again this will flash the running lights at least two times Trailer is now disarmed and safe to enter ...

Page 11: ...ystem from sounding but are unable to check the trailer visually The trigger will stop but the trailer will remain armed Optional Pro Tec System One Plus Pager will notify you of alarm up to 1 mile away There is also a pager key pad that can be used to notify pager without having alarm trigger IMPORTANT The brake safety switch must be turned off before trailer is to be towed This switch is to prev...

Page 12: ...eature is used to tell you if and what trigger point was triggered while you were away It also helps determine where to look if you are experiencing false alarms 1 Steady Flashing System armed 2 No Flashing System disarmed 3 One Flash Generator door 4 Two Flashes Shock sensor 5 Three Flashes Side or rear door To reset LED indicator Disarm alarm Then press reset button on control module LED should ...

Page 13: ...Wiring Diagram ...

Page 14: ...rable and does not apply to any unit that has been modified or used in a manner contrary to its intended purpose and does not cover batteries The unit in question must be returned to the man ufacturer postage prepaid This warranty does not cover labor costs for the removal diagnosis troubleshooting removal or installation of the unit These systems are a deterrent against possible theft TOMAL Syste...

Page 15: ...MERICA AND OR ABROAD NEITHER THE MANUFACTURER OR ANY ENTITIES CONNECTED THEREWITH SHALL BE RESPONSIBLE OR LIABLE FOR ANY DAMAGES WHATSOEVER INCLUDING BUT NOT LIMITED TO AND CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS LOSS OF ECONOMIC OPPORTUNITY AND THE LIKE NOTWITHSTANDING THE ABOVE MANUFAC TURER DOES OFFER A LIMITED WARRANTY TO REPLACE OR RE...

Page 16: ...T OMAL S Y S T E M S LLC Manufacturers of Pro Tec Systems 888 741 1004 252 633 4584 252 636 5704 Fax Serial Date Installed Purchased From ...

Reviews: