IO - 2001 & IO-3001 Ionizer Instruc

ti

 on Manual

Limited Warranty

This PROECO product is covered by a 2-year limited warranty by PROECO PRODUCTS. The limited warranty period begins from the 
date of purchase and covers material and manufacturing defects or failure of the product to operate as speci

fi

 ed by PROECO  PROD-

UCTS during the dura

ti

 on of the limited warranty period.

This limited warranty does not cover failure or problems related to:

 Improper installa

ti

 on, see this manual for proper installa

ti

 on procedures.

 Modi

fi

 ca

ti

 on of the product in any way including a

tt

 empts to repair the product by someone other than a PROECO PRODUCTS 

trained and authorized repair technician.

 Failure to follow proper safety, care and maintenance guidelines as outlined in this manual.

It also does not cover those parts of the product that are subject to normal wear and tear during usage of the product, such as:

 Impellers on pumps

 Filter pads and 

fi

 lter medium in 

fi

 lters

 Lamps in lights and UV clari

fi

 ers

PROECO PRODUCTS's sole liability shall be to replace or repair the product covered by this limited warranty. PROECO PRODUCTS 
shall not be liable for any consequen

ti

 al damage to any other part of the water garden, pond, water feature, landscape, structure, 

or the contents of any structure where the product is located or used including no liability for damage or harm to 

fi

 sh, animals, or 

plants in or around the water  garden, pond or water feature.
THE EXPRESS WARRANTIES SET FORTH HEREIN ARE THE ONLY WARRANTIES WITH RESPECT TO THE PRODUCTS, AND THE REMEDIES 
SET FORTH HEREIN ARE THE EXCLUSIVE REMEDIES IN THE EVENT OF A BREACH OF SUCH WARRANTIES. PROECO PRODUCTS EX-
PRESSLY DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. PROECO PRODUCTS 
SHALL NOT BE LIABLE UNDER ANY CIRCUMSTANCES FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY NATURE, FOR ANY 
BREACH OF SUCH WARRANTIES OR OTHERWISE. Some states do not allow the exclusion or limita

ti

 on of incidental or consequen

ti

 al 

damages, to the above limita

ti

 on may not apply to you.

Should your PROECO PRODUCTS product be defec

ti

 ve or fail under the terms of this limited warranty, you should return the prod-

uct to your PROECO PRODUCTS dealer, along with your original receipt of purchase and any other limited warranty documenta

ti

 on 

you have, for replacement or repair. Should you have any ques

ti

 on about this limited warranty, please contact PROECO PRODUCTS 

at info@proecoproducts.com

MAINTENANCE

1.  Copper (Ion) Tests

: Using a copper test kit, ensure ions are between 0.2 p.p.m. - 0.4 p.p.m.; Test the ion level at least once a  

 

 week 

un

ti

 l you have found the proper duty cycle for your water feature. Increase or decrease the duty cycle as required. Check    

 the 

expira

ti

 on date of the Copper test kit as test results may be inaccurate if used a

ft

 er that date. 

2. Anodes:

 The anodes that deliver current to the water need only be checked once per season and typically last for one year  

 

 

(2,160 “on” hours under normal use condi

ti

 ons). You can purchase addi

ti

 onal anodes from your authorized dealer. To replace   

          

 

your anodes, simply turn old electrodes counter clockwise to release them from the tee, and swap for a new set of  

 

 

anodes,  turning clock wise to fasten them back into the tee.

3. Alkalinity 

- Keep the total alkalinity between 80 and 120 ppm. (Most important!)

4. pH 

Levels

 - Keep the pH levels between 7.2 and 7.8.

5. Calcium 

Hardness 

- Keep calcium hardness between 200 and 300 ppm. 

6.  Total Dissolved Solids

 - Keep total dissolved solids (TDS) between 500 and 2,000 ppm. 

NOTE:

Adding pond salt to the water feature can help adjust and stabilize the Alkalinity, Calcium Hardness and TDS. Make sure to 

follow the pond salt manufacture’s dosage instruc

ti

 ons.

CLEANING & CARE

Anodes: 

Cleaning will remove oxida

ti

 on. Some deposits have a tendency to form on the electrodes depending on the water  

 

condi

ti

 ons. Clean the face of the anodes using a smooth 

fi

 le and some water. The surface does not have to be “polished”; simply 

remove any traces of oxida

ti

 on and other sediments. Remove the old Te

fl

 on tape, use new tape and wrap it around six 

ti

 mes. 

Exterior Housing:

 The housing of the ionizer is made from a durable PVC plas

ti

 c. Clean the outside with a mild soap and water; rinse 

and dry with a so

ft

  cloth. Do not use any type of household or abrasive cleaner.

System Controller:

 Care should be taken in cleaning the controller. If the controller becomes soiled, wipe the panel with a cloth 

dampened slightly with water only. Dry with a so

ft

  cloth. Do not scrub or use any sort of chemical cleaners. 

Winteriza

ti

 on

 - If you choose to winterize your water feature remove the anode assembly from the clear tee and replace it with a 

plug. The controller and anode assembly can then be stored indoors.