background image

FEATURES / SPECIFICATIONS 

(See Diagram 1)

1.

 

Screw Terminal –

 Accepts wire sizes 14 to 28 AWG for connection 

of the following:  

      

• +12V DC – 

Powers connected IR Receivers, Keypads, etc.  

    

  • GND –

 Return for Power, IR signal and Status indicators

      

• ST OUT –

 Connects status voltage to Status Indicators 

        in IR Receivers, Keypads, etc. 

      

• IR IN –

 Receives IR control signals from IR Receivers, 

        Keypads, etc.

2.

  

Mounting Holes –

 Attaches the IR Router to any flat surface 

  using the two screws provided.  

3.

  

FLASHERS – 

Four 3.5mm jacks drive IR Flashers.

4.

 

12V DC REGULATED –

 2.1mm jack, center pin +, accepts 12V DC 

regulated power supplies to power the IR system. Calculate the 

current required, then use either Proficient IR Power Supply–

200mA or 1.2A. 

Note:

 The “no signal” current draw of the IR 

Router is zero.

5.

 

STATUS IN 5-24V DC –

 2.1mm jack, center pin +, accepts 5V through 24V DC power supplies to power 

  system ON/OFF Status Indicators of connected IR receivers, keypads, etc.

6.

 

IR RCVR –

 Exclusive four-circuit 3.5mm jack provides connection for Proficient direct plug-in IR 

  Receivers. Connections are made, not only for Power, Signal and Ground, but for the Status Indicator in 

the IR Receivers as well.

LIMITED 5-YEAR WARRANTY

Proficient warrants to the original retail purchaser only that this Proficient product will be free from defects in materi-

als and workmanship, for a period of 5-years, provided it was purchased from a Proficient Authorized Dealer. Defective 

products must be shipped, together with proof of purchase, prepaid insured to the Proficient Authorized Dealer from 

whom they were purchased, or to the Proficient factory at the address listed on this installation instruction manual. 

Freight collect shipments will be refused. It is preferable to ship this product in the original shipping container to lessen 

the chance of transit damage. In any case, the risk or loss or damage in transit is to be borne by the purchaser. If upon 

examination at the Factory or Proficient Authorized Dealer it is determined that the unit was defective in materials or 

workmanship at any time during this warranty period, Proficient or the Proficient Authorized Dealer will, at its option, 

repair or replace this product at no additional charge, except as set forth below. If this model is no longer available 

and can not be repaired effectively, Proficient, at its sole option may replace the unit with a current model of equal or 

greater value. In some cases where a new model is substituted, a modification to the mounting surface may be required. 

If mounting surface modification is required, Proficient assumes no responsibility or liability for such modification. All 

replaced parts and product become the property of Proficient Products replaced or repaired under this warranty will be 

returned to the original retail purchaser, within a reasonable time, freight prepaid. This warranty does not include ser-

vice or parts to repair damage caused by accident, disaster, misuse, abuse, negligence, inadequate packing or shipping 

procedures, commercial use, voltage inputs in excess of the rated maximum of the unit, or service, repair or modifica-

tion of the product which has not been authorized or approved by Proficient. This warranty also excludes normal cos-

metic deterioration caused by environmental conditions. This warranty will be void if the Serial number on the product 

has been removed, tampered with or defaced. This warranty is in lieu of all other expressed warranties. If the product is 

defective in materials or workmanship as warranted above, the purchaser’s sole remedy shall be repair or replacement 

as provided above. In no event will Proficient be liable for any incidental or consequential damages arising out of the 

use or inability to use the product, even if Proficient or a Proficient Authorized Dealer has been advised of the possibility 

of such damages, or for any claim by any other party. Some states do not allow the exclusion or limitation of consequen-

tial damages, so the above limitation and exclusion may not apply. All implied warranties on the product are limited to 

the duration of this expressed warranty. Some states do not allow limitation on the length of an implied Warranty. If the 

original retail purchaser resides in such a state, this limitation does not apply.

The IR Router provides a convenient means of interconnecting Proficient (and industry compatible) IR products 

in IR repeating systems. It includes a wide bandwidth amplifier for robust operation. It has flasher drive power 

capability and is reverse voltage protected.

FLASHERS

ST

AT

US IN

5-24V DC

IR

RCVR

12V DC

REGUL

AT

ED

FLASHERS

+12V

GN
D

ST OU

T

IR IN

IR

 R

ou

te

r

2

3

3

2

4

5

6

Diagram 1 

1301-82200

OWNER’S MANUAL

IR Router

with IR Parallel Block

940 Columbia Avenue, Riverside, CA 92507

877.888.9004 • Fax 951.787.8747 • proficientaudio.com

IR Parallel Block

The IR Router comes with an IR Parallel Block, which is a 4-conductor screw-

down terminal strip that permits the securing of the several leads coming from 

the various IR receivers. A rule of thumb is to use it whenever you need to 

connect more than two leads to each of the Screw Terminals of the IR Router. 

(See Diagrams 2 & 4)

SYSTEM CONNECTIONS

The following are a few typical applications of the IR Router for IR repeater systems.

A Basic System

Diagram 3

 shows a basic plug-and-play installation, such as controlling components that are behind closed 

cabinet doors or in a nearby closet. 

Diagram 2 

Summary of Contents for IR Router

Page 1: ...odification All replaced parts and product become the property of Proficient Products replaced or repaired under this warranty will be returned to the original retail purchaser within a reasonable time freight prepaid This warranty does not include ser vice or parts to repair damage caused by accident disaster misuse abuse negligence inadequate packing or shipping procedures commercial use voltage...

Page 2: ...nsion Diagram 5 is an example of a 2 room system using two IR Routers for Bi Directional control on a common IR Network This type of connection permits IR Receivers or keypads if used located in each room to control the various components in both rooms whether local or remote You may also use this type of configuration to connect additional IR Routers for IR Flasher expansion so that additional co...

Page 3: ...nsion Diagram 5 is an example of a 2 room system using two IR Routers for Bi Directional control on a common IR Network This type of connection permits IR Receivers or keypads if used located in each room to control the various components in both rooms whether local or remote You may also use this type of configuration to connect additional IR Routers for IR Flasher expansion so that additional co...

Page 4: ...odification All replaced parts and product become the property of Proficient Products replaced or repaired under this warranty will be returned to the original retail purchaser within a reasonable time freight prepaid This warranty does not include ser vice or parts to repair damage caused by accident disaster misuse abuse negligence inadequate packing or shipping procedures commercial use voltage...

Reviews: