background image

PRO

TOUCH

Tm

IMPORTANT:  

Ensure the mains supply is isolated prior to installation.

All heating mats and cables must be earthed.

Electrical work which is subject to Part P Building Regulations must be carried out by a qualified electrical engineer.

All work must conform to BS7671 and the latest 17th Edition wiring regulations.

GENERAL

•  Weekly programming adopting the latest single-chip 

computer control technology.

•  The clock continues after a power failure and the scheduled 

time settings will not be affected.

•  Designed for electric underfloor heating. According to 

the pre-set temperature and time, the thermostat will 
automatically start and stop the floor heating.

•  Multiple schedule settings available: 5+2 / 6+1 / 7 days. 

PROTOUCH  supports different temperature settings 
accordingly with 6 time modes daily.

•  Users are free to choose manual and full automatic mode for 

operation.

• Keypad lock function. 

• Flame retardant, safe and easy cleaning. 
 
Wiring details: These are printed on the back of the 
thermostat casing.  
The floor sensor is connected to terminals T1 & T2 (please 
note there is no polarity and the twin core sensor cable can 
be connected either way). The 230V electrical supply connects 
to terminals L (Live) & N (Neutral). The heating mat(s) connect 
to terminals L1 (Live) & N1 ( Neutral). Earth connections are 
made with the back box.  When the thermostat is powered 
for the first time you may see “OFF” on the screen in the lower 
sub-display.

Press ON / OFF symbol to activate and turn on your 
thermostat. 

Keypad Lock   -  Press Clock symbol and Menu at the same 
time for 2 seconds. 

Repeat to unlock. LCD display will show the temperature value 
when keypad is locked.

Technical Parameters

Power supply:

 230VAC 50/60 Hz

Maximum switch power:

 16A / 3,600 watts

Internal Sensor: 

 Setting Range 5°C ~ 35°C

External Sensor:

  Setting Range 5°C ~ 95°C

Sensor:

 NTC3380, 10Kohms @ 25°C

Temperature setting steps:

  0.5°C

Display type: 

LCD     

Display area:

 60 x 45m

Touchscreen Thermostat User Manual

Press the power ON/OFF key to turn the thermostat ON 
or OFF. The display will be as below when turning OFF.

Summary of Contents for Touchscreen Thermostat

Page 1: ...y cleaning Wiring details These are printed on the back of the thermostat casing The floor sensor is connected to terminals T1 T2 please note there is no polarity and the twin core sensor cable can be connected either way The 230V electrical supply connects to terminals L Live N Neutral The heating mat s connect to terminals L1 Live N1 Neutral Earth connections are made with the back box When the ...

Page 2: ...previous settings Finally press ON OFF twice to confirm If you want to turn off a period then in the temperature setting for the period press DOWN until OFF is displayed in the temperature screen then press Menu to confirm To quickly return to the original display press ON OFF twice The system default is 5 2 and the default settings are as the following table For example when the system time is Fr...

Page 3: ...ault set to 1 C then at higher than 21 C the heater turns off and at lower than 20 C the heater turns on 1 C External sensor hysteresis dt1 0 5 C to 5 C 3 C Backlight status bL ON Always on OFF Auto turn off after 5 seconds OFF Status at re power Sat ON The same as previous OFF Off status every time Keep this setting as default OFF OFF Restore factory settings deF Restore to factory settings ADVAN...

Page 4: ...deformed correct it Large deviation of measured temperature and the actual temperature a The thermostat should be installed in a ventilated room and never in direct contact with sunlight or localised heaters b Check terminal connections including the sensor INSTALLATION A Hook B Central fixing lug 1 Remove the bezel to start the installation by pushing the bezel away from the main body of the ther...

Reviews: