background image

 

User Manual kardiomed  cycle 200 med

 

Version 1.0 

Seite 1 von 15 

 

 

 
 
 
 
 

 

 

Summary of Contents for kardiomed 200 cycle

Page 1: ...User Manual kardiomed cycle 200 med Version 1 0 Seite 1 von 15 ...

Page 2: ...9 5 6 Adjusting the resistance 9 5 7 Training control via the storage media 10 5 8 Results 10 5 9 Programs of the cycle 10 5 10 Pulse controlled Training 11 5 11 Interface PC 11 6 Maintenance 12 6 1 Instructions for the error condition detection failure 12 6 2 Instructions for preventive maintenance by the operator 12 6 3 Maintenance for authorised specialists 13 6 4 Performance of the metrologica...

Page 3: ... has to be less than 130 kg 3 Assembly for partly disassembled delivery To ensure a cost reduced transport the unit of this type can get delivered partly disassembled This way up to 4 units fit on one pallet Is this the case the unit has to get assembled as followed 1 Check the main components for completeness 2 and then the screw set 3 First the feet get mounted Therefore place the corpus on a so...

Page 4: ... the red cable coming out of the unit mast through the according hole on the backside of the monitor 15 Place the plug on the horizontal placed socket You can recognize the proper lock in place by a klick 16 Next the monitor front gets put back on and the monitor gets fixed with the four screws D 17 Afterwards the 4 outer casing screws get screwed back in to seal the casing properly 18 The flat st...

Page 5: ... 1 Safe assembly of the unit Adjustment feet for levelling Pedals Handlebar Saddle Adjusting screw for the horizontal saddle adjustment Adjusting lever for the vertical saddle adjustment Position of the Typ Label Monitor for individual settings and visualization of the training data ...

Page 6: ...lance on the pedals Please check the unit before exercising for a good level faulty parts or other manipulations In case of a defect or if you are not sure ask a supervisor Before the beginning of the workout it must be assured that no one is close to moving parts to avoid a danger for a third person Above all hold unattended children off the units As a safety function the stop button is always ac...

Page 7: ...hich transfers the signals This magnetic field can be interfered by several sources The most common reason is the use of breast belts that are not 100 compatible with the Polar System and commonly have a longer range Cell phones speakers TVs power lines fluorescent tubes and motors with high power can also interfere with the Polar Pulse System The measuring of the pulse frequency is ECG precise On...

Page 8: ...e Cool button stops the workout before the end of the chosen program begins with the cool down mode and finishes the workout with a low intensity The workout data is shown and saved on the storage media if the workout has been started using a storage media Reset button Initially the Reset button is not visible for the user It is hidden in the extension of the upper edge of the LCD display to the l...

Page 9: ...ce is displayed K Cal Depending on the program the accumulated calories burned or the remaining calories to be burned are shown Level Display of the actual intensity 1 21 Storage media The symbol for the storage media appears whenever a member card is inserted into the slot If any of the digital figures are shown in combination with this symbol the figures shown are average figures of the workout ...

Page 10: ...tions of the trainer card Deleting the data on member media If you want to delete all data of a medium then you have to insert the trainer medium twice Afterwards you insert the member medium and all the data on the card will be deleted The Results total can be deleted by pushing the buttons and 3 seconds at the same time Only the results will get deleted not the training plan Functioning of the M...

Page 11: ...d but not exceeded Additionally the program can evaluate the development of the heart rate and use the determined fitness level to adjust the resistance which allows for an optimal warm up If the initial resistance is set above a certain limit no warm up will be done and the resistance is immediately adjusted to the desired heart frequency see motion pulse manager brochure This program functions i...

Page 12: ...e material Check the cranks and pedals for damages and tightness In general Clean the devices with mild purifier and a wet cloth to get off aggressive sweat Dry the device afterwards The usage of spray bottles is not allowed it has shown that the unit never dries at spots that can t be reached Rust may occur Pay attention that no liquids run into the monitor as it could destroy parts of the electr...

Page 13: ...professional Contact your dealer in case you need a reference 6 5 Conduction of a safety related control According to the transposition of the medical device directive 93 42 EEC into national law At all medical training devices a technical safety check has to be conducted at least every 12 months and after repair by an authorized employee or partner This check needs to also include the control of ...

Page 14: ...exchange unit is arranged and sent to the user The defective parts must be sent to proxomed within 48 hours Otherwise the cost for spare parts that have been delivered will be charged If causes for repairs lie outside of the warranty conditions proxomed Medizintechnik GmbH reserves the right to require payment for all costs of the repair Some consumable parts are excluded from the warranty These i...

Page 15: ...ed ch Changes proxomed reserves the right to change any product if this action in our opinion leads to improved quality and functionality All images in these operating instructions are due to printing only similar We take no responsibility for printing errors Errors and omissions excepted User Manual kardiomed 200 cycle valid since Oct 2015 emotion fitness GmbH Co KG is a company certified by the ...

Reviews: