background image

t‹ˆ@tžŒ™šˆ˜

  

by Prozone

Advanced Oxidation Air Purification System

TM

WARNING: Risk of electric shock, fire and burns. Unit to be serviced by qualified personnel only.

To reduce the risk of burns, electric shock and fire, this product must be used in accordance with these instructions.

This equipment has a polarized plug. This plug will fit in a polarized outlet one way. If plug does not fit fully in outlet, reverse the plug.

(If plug still does not fit, contact qualified personnel to install proper outlet)

Do not open the case for any reason.  High voltage and UV radiation are inside the unit.  Opening the case and  viewing the lamp can cause severe 
eye damage or irritation.

Individuals with asthma or other respiratory problems should consult a physician before using this product.

Continuous Ozone Output Mode: Operate for no more than fifteen minutes per hour when occupants are continually present.

Never inhale ozone directly from the unit.

Connect only to 110/120 volt AC (alternating current).  Never connect to DC (direct current).

Never immerse unit in water or any liquid.  Never use the electrical cord as a handle.  Never pull the unit by the electrical cord.

IMPORTANT NOTE: Opening the case will invalidate the warranty.

GUIDE TO CONTROLS

1 - System On-Off switch 

2 - Ozone/Timer select switch  

3 - Timer   

4 - Timer Dial (24 hour, 15 minute increments)

5 - Timer setting pins 

6 - Timer set point arrow

7 - Intake fan, with washable filter 

8 - Output vent  (On rear, not shown)

The Timer

Timer Dial - The timer dial contains the full 24-hour cycle.  There is one timer setting pin for each 15-minute interval.  The dial is divided into black 
and white sections: use the white section for 6:00 am to 6:00 pm, the black section for 6:00 pm to 6:00 am.

Setting the Current Time - Turn the Timer Dial (4) clockwise and align the current time with the timer set point arrow (6).

Timer Setting Pins (5) - Activated Position: To activate a timer setting: Push corresponding timer setting pin (5) in, toward center of dial. Apply firm 
pressure against notch on outside of pin, using fingernail or coin if necessary. Pin clicks into place, and orange rim of timer dial becomes visible. The 
setting is retained from day to day, until pin settings are changed; no resetting is required except when changing the schedule .

Timer Setting Pins - Inactive Position: To cancel a specific timer setting: Pull the corresponding timer setting pin out toward the outer rim of the dial.

Timer Setting Pins - Factory Pre-Sets: Some timer setting pins may be factory pre-set.  Be sure to review these settings and change the settings if 
you prefer a different schedule.

MODES OF OPERATION

Germicidal Air Purification Only

germicidal purification is always occurring whenever the system is on

Timed Ozone Air Purification plus Germicidal Air Purification

most common mode used; powerful air purification at user-defined 15-minute time periods

Continuous Ozone Air Purification plus Germicidal Air Purification

heavy-duty odor & contaminant problems; use when treating unoccupied areas

User Manual

IMPORTANT SAFETY INSTRUCTIONS

1

6

5

4

3

1

2

ON

OFF

OZONE

TIMER

7

Reviews: