background image

 
 
 
 
 

User’s Manual 

 

 
 
PTS-G3K13M 

RF Generator 3kW / 13MHz 

 
 
 
 
 
 
 
 
 

 

PTS co.,Ltd. 

68-1, Sangdeok-ro, Idong-myeon, 
Cheoin-gu, Yongin-si, Gyeonggi-do, 
#17126, Korea 
Tel. 031-321-5670 
Fax. 031-332-5670 

Summary of Contents for PTS-G3K13M

Page 1: ...User s Manual PTS G3K13M RF Generator 3kW 13MHz PTS co Ltd 68 1 Sangdeok ro Idong myeon Cheoin gu Yongin si Gyeonggi do 17126 Korea Tel 031 321 5670 Fax 031 332 5670 ...

Page 2: ...Co Ltd 2 Contents 1 Safety Precautions 2 System Standard 3 Dimensions 4 RF Generator System Overview 5 Installation 6 A D Interface 7 Handy Controller Remote Operations 8 Interlock and Alarm 9 Warranty and Maintenance ...

Page 3: ...cated on the diagrams contained in this manual Ground the Equipment To prevent electrical shock by the AC power source please make sure that the equipment is securely connected to ground If the product generates any abnormal smells or noises during use immediately switch the power off and unplug all power cables including AC adapter from the outlet Make sure power for all equipment is turned OFF b...

Page 4: ... we are not responsible under any circumstances This equipment should not be inspected by one person only Make sure that the person who operates the RF Generator is always around Do not change parts or modify this equipment Unauthorized Parts modification or change may cause serious problems Please contact us up on replacement or modification Pay attention to warnings and cautions All warnings and...

Page 5: ...sult in serious injury or worse It warns that there is a potential risk A symbol shows a care that should be taken to avoid danger or mistakes It tells you potential activities to reduce serious damage This sign is physical damage due to high voltage It warns the product weights more than 20kg and tells to Use Lifting Aids with Proper Lifting Techniques to ask for help ...

Page 6: ...PTS G5K13M PTS Co Ltd 6 This symbol is asked to refer to the Manual for reliable equipment operation This symbol indicates the position where one has to connect Ground for reliable equipment operation ...

Page 7: ...ion 0 5 Power 0 RF OFF 2 100 RF Output accuracy 2 Output Deviation 2 설정한 값 또는 2W 둘 중 큰 값 Spurious 2f 40dB 3f 45dB Output Impedance 50Ω Arc cut detecting 2usec RF Connector Type HN Type Connector Slow UP DOWN Time 0 3sec 0 1sec Cooling Type Air Water Water Supply 7ℓ min 10 30 Water Connector RC 3 8 Use Condition Temperature 5 40 Humidity 10 80 Size 267 146 480mm Case Front Panel Gray ...

Page 8: ...C terminal Device Net Selectable on the rear of Generator 2 3 Installation site Please maintain the ambient temperature to 5 40 when the generator is in operation Power output ON Please keep in storage area of temperature 25 55 when it is not under operation Do not install in places with high humidity dusty where there is a direct sunlight or places where there is any risk of water or other liquid...

Page 9: ...PTS G5K13M PTS Co Ltd 9 3 Dimensions ...

Page 10: ...rator Status Display LED POWER It displays the main power input status It lights when power is turned on INT L External interlock light turns on when normal RF ON LED Light turns on when RF On is on ALARM Light turns on when there is a warning TEMP Light turns on when high temperature reading is there COAX Light up when COAX cover removed PLUSE ...

Page 11: ...PTS G5K13M PTS Co Ltd 11 Circuit protector Main Switch 4 2 Rear ...

Page 12: ... 8 Water Cooling output RC 3 8 Analog Interface D SUB connector 25P for the A D Interface XM2C 2512 RF output connector HN Type Female Connector cover Protection circuit circuit breaker D Net D Net Connector 5 Installation guide There is a risk of electric shock Please be careful when installing the items below ...

Page 13: ... the RF power output 5 1 Cable Connection Power Connection Always turn Off power switch and circuit breaker of the power supply before connecting the RF Generator There is a risk of electric shock unless you connect the power cable is connected to each phase and ground Please check that it is properly connected Power Plug Pin Phase A R B S C T D N RF Connection Make sure the power is switched OFF ...

Page 14: ...nect a Control Signal to the Analog Interface Terminal D Sub 25pin Confirm whether interface 3 5 connected to A D interface Pin assignment 6 A D Interface Pin Assignment Pin No Name I O Type Function 1 RF On Off Input Contact RF on off Max 5V 1mA 2 INT L Input Contact Interlock Max 5V 1mA ...

Page 15: ...NC 14 D GND Input Contact RF On Return 15 A GND Input Contact Interlock Return 16 A GND Output Analog RF On Status Return 17 A GND Output Analog ALARM Return 18 A GND Output Analog Int Ext Status Return 19 NC 20 A GND Input Analog RF Set Return 21 A GND Output Analog FWD Monitor Return 22 NC 23 A GND Output Analog REF Monitor Return 24 NC 25 NC Please use D GND and remove A GND Analog Interface Co...

Page 16: ...nerator internal Alarm Signal Pin 4 17 Open when normal Close when internal problem occurs INT EXT Status INT EXT Signal state RF Set RF Power Set voltage Pin 7 Set RF to a 0 10V RF Output Power Set 0 3 000W to 20 A GND Pf Moni FWD Power Monitor 7 Handy Controller 7 1 Handy Controller Keep in mind that incorrect operation of Handy Controller may a cause problem ...

Page 17: ...ystal display W 62 0 H 44 0 Resolution 128 64 Buttons A D Buttons and mini tact switch are used Key top is a panel sheet film Software determines operational functions Communication connector CONT HR10 7R 6P Connects with Matching Box CONT connector ...

Page 18: ...function displayed next to the corresponding button Functions correspond to A D Buttons from top to bottom EXT maintenance Mode Analog I O Control INT Internal Control State RS232 Communication Control RF Output Monitor Corresponding to A Button Corresponding to B Button Corresponding to C Button Corresponding to D Button Status Display Status Display Button Function ...

Page 19: ...RF ON USET POWEr 1 is displayed when you press D button UFUNCU 2 it goes to power SETUP Screen 1 2 In the function setting screen select U OPERATEU 3 to move to U Operate Screen 3 From UOPERATE Screen 4 move the underscore to the item you want to select by pressing QUIT 5 D Button 4 5 6 Confirm Screen SET POWER 화면 FUNCTION 화면 OPERATE 화면 ...

Page 20: ...ting the SLOWUP Screen 7 to move to Slow up setup screen 7 Slow up down setting can be operated using A button and B button 8 Press once to increase the setting to 50 Press once to decrease the setting to 50 It is set in the range of 300msec 5000msec 8 After setup is completed it can be set by pressing the QUIT D button A Function Setting Screen Slow up down Setting Screen 1000msec Setting Slow up...

Page 21: ... of the equipment Internal Control during Operation RF Output Method From USET POWER screen by pressing the Internal control button OUTPUT 9 The RF output confirmation screen is displayed 9 Confirmation screen How to set the output power RF power setting operation of the B button PF U 10 and D button PF 11 Pressing once increases the value by 1 Pressing once decreases the value by 1 This change wi...

Page 22: ...S G5K13M PTS Co Ltd 22 10 11 Alarm Confirmation The error status on alarm confirmation screen of the RF power can be checked If an error occurs error checking screen is displayed Error confirmation screen ...

Page 23: ...d Temp sensor fail Check water flow and air flow around the rear of the generator and start again 만약 Water flow 및 흡 배기팬이 정상인 경우 수분이 지나도 Temp Err가 해제되지 않는다면 당사에 문의 바랍니다 Cover Err While generator is under operation if the Cover or Coaxial Cable Cover is removed it could cause an accident caused by a high voltage Make sure the connection of the coaxial cable Amp Err This error occurs due to parts in ...

Page 24: ...tionality to protect against Reflect Power 8 3 Maximum Output Control The RF Generator has embedded functions to control the maximum output Please refer Handy Controller usage 8 4 Slow Up Down 본 Generator는 안정적인 플라즈마 형성을 위하여 설정 Power까지 도달하는 시간을 지정할 수 있습니다 사용자 설정에 의하여 300 500msec까지 설정가능하며 설정시 Set Power까지 Forward Power가 도달하는 시간이 선형적으로 변경됩니다 Slow Down은 Option사양이므로 당사 문의 바랍니다 8 5 Arc Cut 본 Generator는 A...

Page 25: ...roducts delivered in South Korea Additionally repairs for failures due to the following will be require payment for service from the customer even within the warranty period 10 1 Cases of Warranty Exclusion Wearing out of consumable parts Improper handling by the customer Use outside of prescribed usage environment ranges User modifications Natural disasters or accidents causing damage to the unit...