background image

 

                                   

                                            

    

       

 

Code:

 

ARAD-S4

 

Name:

 

Security enclosure 4U/400mm/48/17Ah for RACK 19" 

cabinets two-level 

                                                                      

v1.0                                                

                                                                                                                                                                  

EN

                                                       

 

                                                                      

 

                                                                                                                                                                

                                                                                                                                                                                                                                      
                                                                                                           Edition: 1 from 14.06.2017 

                                                                                                                         

Supersedes: --------------  

                                                                                                                

 

            

                                                                                                                                  

 

1

Intended use:

 

 

 

The metal RACK-Security enclosure is designed for mounting the alarm control panel and the input/output modules in 

free-

standing RACK19” cabinets with depths in the range from 800 to 1000mm. It consists of two elements: 

 

1. 

Patch Panel

 is used to switch between the YTDY 6x0,5 cable with copper cores and the elastic cable supplying 

signals and power to the control panel. 
 

2. 

Pull out enclosure with a 4U height

 

– alarm control panel and input and output modules are mounted in this 

section - with a space for 17Ah battery, transformer, and the ARAW45 fan (transformer and fan are not included). 

 

Both 

ARAS800

 and 

ARAS1000

 rails -    selected depending on the depth of a RACK cabinet - constitute the load 

bearing part of the enclosure (not included). The enclosure is fitted with 6 printed circuit boards (PCB) allowing connection 
of signal, power and control cables. Each of the boards has 8 pairs of terminals designed to operate at a voltage of 30VDC 
and a maximum current of 1,5A In addition, each one is fitted with the 230VAC power board. The enclosure is fitted with 3 
tamper switches: 

 
1.  Pulling out the enclosure from RACK profiles 
2.  Enclosure opening 
3.  Patch Panel opening 

 

Universal holes in the enclosure allow mounting of control panels and expansion modules of the following companies:  

DSC, PARADOX, RISCO, SATEL, PYRONIX, CROW, ROGER. 

 

 

 

 

Fig.1 

 

 

Summary of Contents for ARAD-S4

Page 1: ...ith a space for 17Ah battery transformer and the ARAW45 fan transformer and fan are not included Both ARAS800 and ARAS1000 rails selected depending on the depth of a RACK cabinet constitute the load bearing part of the enclosure not included The enclosure is fitted with 6 printed circuit boards PCB allowing connection of signal power and control cables Each of the boards has 8 pairs of terminals d...

Page 2: ...ile is properly adjusted Fig 2 3 Mounting of the ARAD S4 in the RACK 19 cabinet After mounting the ARAS rails in the rear of the RACK 19 mount the Patch Panel as shown in Figure 3 Fig 3 Mount the ARAD S4 enclosure on fully extended ARAS rails using 6xM4 screws complete with ARAS rails Tighten the screws from the inside Connect the Patch Panel wires as shown in the Fig 4 CAUTION Pay attention to th...

Page 3: ...64 Protective tube for signal cables 24 YTDY 6x0 5 wires internal external diameter ø21 ø29 available as accessory MM020 The routing of protective tubes in the Patch Panel and its sealing is shown in the Fig 5 Fig 5 The ARAD S4 enclosure is fitted with 3 tamper switches 1 Pulling out the enclosure from RACK profiles 2 Enclosure opening 3 Patch Panel opening The enclosure is mounted in the front of...

Page 4: ... PCB supply 230VAC max 5A PCB Power Board in the Patch Panel PCB Power Board in a retractable housing PCB Signal Boards Single PCB Signal Board allows connecting up to 8 signal supply lines The maximum operating conditions of a single line 30VDC 1 5A PCB Signal Board in the Patch Panel PCB Signal Board in a retractable housing ...

Page 5: ...5 5 Additional equipment Space for 17Ah battery TRP TRZ 20 80VA transformer ARAW45 fan 230VAC board with the F3 15A melting fuse 6 Dimensioning Mounting plate Hinged mounting plate ...

Page 6: ...UB2 RISCO PRO24 PRO116 PRO128 PRO140 5 x EZ04 EZ8 EZ16 RP296EPS SATEL CA4V1 CA5 CA6 CA10 VERSA5 10 15 INTEGRA24 32 64 128 CA64 PTSA CA64 PP 5x CA64E CA10E PP EPS ADR O R O ROC O OC OPS OC OPS R OPS ROC VGM 16 SR PTSA PYRONIX MATRIX 424 832 832 TEXECOM PREMIER412 816 832 48 88 168 640 TELMOR TCA 824 5 x TEX800 TMT1 ROGER PR402 CPR 32 SE EBS PX 202A PULSAR 5x MS1012 MSR1012 MSRK1012 5x MS2012 MSR201...

Page 7: ...eight 14 15 kg Finish steel plate 1 1 5mm color black RAL 9004 Application Indoor Notes The enclosure is mounted using the ARAS800 1000 rails depending on the depth of the RACK 19 cabinet 4xM6 screws butt mounted to RACK profiles Patch Panel mounting 8xM6 butt mounted to RACK profiles 2xM6 to ARAS800 1000 rails The set includes protective tube MM020 ø21 ø29 0 5m 2 pieces protective tube MM064 ø6 ø...

Reviews: