INSTALLATION GUIDE
ENGLISH
Code:
ARAD4S
Name:
RACK 4U/270mm universal enclosure
for RACK 19" two-level cabinets
Metallic enclosure for RACK cabinet: CCTV, KD, SSWiN, RTV, LAN
IM ARAD4S
Edition: 2 from 04.10.2021
Supersedes the edition: 1 from 20.03.2017
EN
1. Intended use:
Due to its design, the ARAD4S enclosure is intended for mounting inside RACK 19'' cabinets. This general-
purpose enclosure may serve as an auxiliary element for integrating CCTV, AC, I&HAS, RTV, LAN systems in RACK 19''
cabinets. It is intended for mounting alarm control panels, AC controllers, power supply units, batteries, etc.
2. Description
The enclosure is equipped with two bottom-mounted mounting plates and a removable hinged mounting plate
(I and II level) for mounting electronics/transformers/power supply units. The enclosure can accommodate a 17Ah/12V
battery and it features tampering protection (against unwanted opening). To enable leading cables into the enclosure,
one can buy a cable protection conduit of any length and a cable gland. The conduits and the cable glands are available
at the following codes:
1)
ARAP16P
– cable gland, inside diameter 16 mm – connection between the protection conduit and the enclosure
2)
ARAP21P
– cable gland, inside diameter 21 mm – connection between the protection conduit and the enclosure
3)
MM019
– cable protection conduit , inside diameter 16 mm
4)
MM020
– cable protection conduit, inside diameter 21 mm
The
ARAD4
enclosure has a space for up to 4x ARAP16P and 8x ARAP21P cable glands.
Optionally,
ARAW45
fans can be mounted. They trigger airflow inside the enclosure after exceeding 45
o
C. One
enclosure can accommodate max. two fan units in the rear part of the enclosure.