Generator

Model: PG15KVTW

www.pulsar-products.com

OPERATOR’S MANUAL

Summary of Contents for PG15KVTW

Page 1: ...Generator Model PG15KVTW www pulsar products com OPERATOR S MANUAL ...

Page 2: ...erator to an Electrical System 13 Operation 14 How to Start Engine 14 Battery Charger for Electric Starter 15 Grounding the Generator 14 How to Stop Engine 16 Receptacles and Extension Cords 16 Don t Overload Generator 17 Wattage Reference Guide 18 Charging a 12 Volt Battery 19 Cold Weather Operation 19 Maintenance 20 Maintenance Schedule 20 Engine Maintenance 20 Battery Maintenance 20 Maintaining...

Page 3: ...To order parts receive warranty assistance or other services inquiries you can contact us by internet at www pulsar products com or write to us at The emissions control system for this generator is compliant with all standards set by the Environmental Protection Agency AC Output Rated Wattage 12 00W 12 0kW Rated Voltage 120 240V Rated Frequency 60Hz Rated Output 12 0kVA Maximum Output 15 0kVA Reco...

Page 4: ...f serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigue nausea fainting Never use indoors in a covered area or in a confined space even if doors and windows are open Keep exhaust from this unit from entering a confined area t...

Page 5: ... If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the fuel shutoff valve turned to the off position WARNING Never exceed generator s wattage amperage capacity This could damage the generator...

Page 6: ...r will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Never handle the generator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a ground fault circuit interrupter GFCI in a damp or highly co...

Page 7: ...rs F 120V 240V Volt 50Amp RV Outlet G 120V 240V 30 Amp Twist Lock L14 30 H 120V 30 Amp Twist Lock L14 30 I Four 120V Outlets H E F G J AC Breakers NEMA L5 30 120 240V 50 A 120 240V 30 A 120V 30 A 120V 20 A 120V 20 A PUSH START RUN STOP PUSH BUTTON AUTOMATIC TRANSFER SWITCH V F T METER MAIN BREAKER AC BREAKER AC BREAKER AC BREAKER AC BREAKER AC BREAKER ...

Page 8: ...8 FEATURES K Fuel Tank Vapor Vent L Handle M Support Foot N Top Handle O Fuel Gauge M K S Q R T P L O N P Gas Tank Q Fuel Valve ON OFF R Oil Fill S No Flat Tires T Battery ...

Page 9: ...n the sides of the box being careful to avoid hitting the generator 4 Leave generator on box to install wheel assembly Packing List Check all loose parts to the following list Contact your dealer if any loose parts are not included Description Qty Generator 1 Operator s manual 1 Product registration card 1 Toolkit Spark Plug Wrench 1 1 Washer 2 Description Qty Supporting Leg Nut 2 2 Funnel Handle ...

Page 10: ...ing M8 screws 2 and nuts Fig 2 Installing Support Leg See fig 2 Fig 3 Parts needed 2 wheels 2 axles 2 hair pins and 2 washers Raise or tilt generator so you can slide the wheel axle pin into the wheel the washer the wheel mounting hole located on the side of the frame Secure the wheel assembly by reinserting a hair pin through hole at the end of the wheel axle and pressing until it locks into plac...

Page 11: ...h hands after touching battery WARNING Battery posts terminals and accessories contain lead and lead compounds known to cause cancer and reproductive harm NON SPILLABLE SEALED BATTERY This is a ready filled activated sealed battery Never remove strip Refer to owner s manual or instruction sheet for charging procedures l DANGER POISON SHIELD EYES EXPLOSIVE GASES CAN CAUSE BLINDNESS OR INJURY NO SPA...

Page 12: ...AE10W 30 to empty reservoir until oil reaches the outer edge of the oil fill hole crankcase dipstick hole Be sure to replace dipstick before attempting to start the engine To check oil set generator on a level surface wipe dipstick clean then reinsert dipstick without rethreading Adding Checking Engine Oil See fig 4 Eyes Flush with water Get immediate medical attention You must add oil before firs...

Page 13: ...an to install a transfer switch Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System a transfer switch The power from the generator must be isolated from th...

Page 14: ...ults from a build up of static electricity or undetected ground faults Fig 6 Place generator on a level surface All electrical loads MUST be disconnected from generator Turn fuel valve to the ON position Push and hold the engine PUSH START button for a couple of seconds until the generator starts Press the Run Stop switch to the Run position Do not hold the PUSH START button for more than 15 secon...

Page 15: ...EMA L5 30 120 240V 50 A 120 240V 30 A 120V 30 A 120V 20 A 120V 20 A PUSH START RUN STOP PUSH BUTTON AUTOMATIC TRANSFER SWITCH V F T METER MAIN BREAKER AC BREAKER AC BREAKER AC BREAKER AC BREAKER AC BREAKER STOP RUN Fig 7 Fig 8 NEMA L5 30 120 240V 50 A 120 240V 30 A 120V 30 A 120V 20 A 120V 20 A PUSH START RUN STOP PUSH BUTTON AUTOMATIC V F T METER MAIN BREAKER AC BREAKER AC AC BREAKER AC BREAKER P...

Page 16: ...ect against overload Each socket is rated to operate 120 Volt AC single phase 60Hz loads requiring up to 2400 watts 2 4 kW at 20 Amps Use extension cords having a minimum rating of 125 Volts AC 20 Amps How to Stop Engine See fig 12 14 Fig 12 Fig 13 Fig 14 OPERATION This receptacle has a 30 Amp push to reset circuit breaker to protect against overload This receptacle is rated to operate 120 Volt AC...

Page 17: ... watts for all electronic devices connected to the generator Rated watts refer to the power a generator must supply to keep a device running Surge watts refer to the power a generator must supply to start an electronic device This power surge for starting a device usually lasts between 2 3 seconds but this additional output must be taken into account when selecting the electronic devices you plan ...

Page 18: ...00 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric Blanket 400 400 Space Heater 1800 1800 Kitchen Blender 300 900 Toaster 2 slice 1000 1600 Coffee Maker 1500 1500 Electric Range 1 element 1500 1500 Dishwasher 1500 3000 Electric Oven 3410 3410 Electr...

Page 19: ...eze To prevent icing take the following steps 1 Replace any old fuel with clean fresh fuel 2 Use synthetic 5W 30 or SAE 5W 30 engine oil Check oil daily or after every 8 hours of use 3 Turn fuel valve to the open position 4 Ensure generator is serviced according to the maintenance schedule under Maintenance section of manual 5 Shelter unit from elements OPERATION 19 Hour Meter See Fig 15 The digit...

Page 20: ...e any debris that has collected on the generator and around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Charge electric starter see Battery Charger for Electric Starter pg 15 Store unit in a clean and dry area WARNING ...

Page 21: ...ainage plug and allow oil to drain completely Reinstall oil drainage plug tighten securely To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove dirt from filter by tapping on it or having it blown out Replace with new filter annually Reinstall air filter so that it seals and replace air filter cover A dirty air filter will reduce the life span...

Page 22: ...ir shop Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up CAUTION Spark Arrestor See Fig 20 If Applicable Inspect the spark arrestor for breaks or holes Replace if necessary To purchase a replacement spark arrestor contact PULSAR customer service Use a brush to remove carbon deposits from the spark arrestor screen as need...

Page 23: ...wing you to access the petcock When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on petcock Reinstall the fuel valve knob in the valve bracket Push forward until knob snaps securely into position Remove the fuel line that leads to the carburetor from the petcock by squeezing the ends of the hose clamps and sliding the fuel line off Draining the carbureto...

Page 24: ...ter in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded 1 Turn switch to ON 2 Replace Air filter 3 Clean or replace fuel filter 4 Replace fuel 5 Reconnect spark plug wire 6 Replace spark plug 7 Drain fuel tank and replace fuel 8 Turn fuel valve to ON pos...

Page 25: ... components parts and labor Year 2 Limited coverage on generator engine components parts only Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial construction or other income producing purposes Once a generator has been used for commercial purposes it shall thereafter be considered as a commercial...

Page 26: ... the United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product to the place of purchase or mail the original re...