background image

RSFUPS108 

v.1.0 

 

10-ports switch with buffer power supply for 8 IP cameras,  

  

RACK mounted 

EN 

Edition: 1 from 22.09.2017 

Supercedes the edition: ------------ 

 

 
 

 

 
 
 

 
 
 

 

 
 

 
 

              

 
 

 

 

 
 
 
 

 

 
 
 

Summary of Contents for Rack Power RSFUPS108

Page 1: ...RSFUPS108 v 1 0 10 ports switch with buffer power supply for 8 IP cameras RACK mounted EN Edition 1 from 22 09 2017 Supercedes the edition ...

Page 2: ...d power supply 2 ports 10 100 1000Mb s ports G1 TP G2 TP UpLink 2 ports 10 100 1000 Mb s SFP G1 SFP G2 SFP ports 15 4W for each PoE port supports devices complaint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size battery charging and maintenance control excessive discharging UVP protection battery output protection against short circuit and reverse conne...

Page 3: ...The LED lights at the front panel indicate the operating status of the device The switch is fitted with the ALARM technical output of collective failure In the case of failure a LED light is activated which is accompanied by switching of relay contacts and acoustic indication The PoE technology ensures a network connection and reduces installation costs by eliminating the need to supply a separate...

Page 4: ...ion indication OFF PoE port 1 8 for cameras IP connection data power supply 2 x UPLINK ports G1 TP G2 TP 2 x UPLINK ports G1 SFP G2 SFP 230V AC INPUT power socket 230V AC power cable 1 5m included FMAINS fuse in the supply circuit 230V AC T 3 15A 250V Fig 2 The front power of the power supply unit Fig 3 Rear panel of the power supply Fig 4 The view of the PSU ...

Page 5: ...2 3af 1 8 ports 48VDC 15 4W at each port Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Forwarding rate 10BASE T 14880pps port 100BASE TX 148800pps port Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 15 4W per port is the maximum value The total power consumption should not exceed 96W wh...

Page 6: ...DC Operating parameters tab 7 Environmental class II Operating temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 90 without condensation Vibrations during operation unacceptable Impulse waves during operation unacceptable Direct insulation unacceptable Vibrations and impulse waves during transport According to PN 83 T 42106 2 Installation 2 1 Requirements The PSU RACK shall ...

Page 7: ...nnectors and connect the recorder to the network the UPLINK connector 6 Make the following technical connections when needed ALARM technical output of collective failure indication 7 Check the optical indication of the switch operation 3 Indication of the device operation 3 1 LED indication of operating status The PSU has 5 LED lights at the front panel GREEN LED on the PSU is supplied with 230V A...

Page 8: ...mission CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP slots is shown on the LEDs located near the RJ45 connector see below CAUTION G1 TP and G1 SFP or G2 TP and G2 SFP sockets can not operate simultaneously These are COMBO type sockets GREEN LED LIGHT SPEED OFF connection 10Mb s or 100Mb s ON connection 1000Mb s CAUTION The operating status of the G1 TP G1 SFP G2 TP and G2 SFP ...

Page 9: ...restoration of the voltage takes place immediately once the failure overload is over 4 2 Battery assisted operation In case of a main power outage the device is immediately switched into a battery assisted operation The PSU is equipped with the discharged battery disconnection system During the battery assisted operation reducing voltage below 19V at the battery terminals will cause battery discon...

Page 10: ...and electronic equipment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable law Pulsar Siedlec 150 32 744 Łapczyca Polska Tel 48 14 610 19 40 Fax 48 14 610 19 50 e mail biuro pulsar pl sales pulsar pl http www pulsar pl www zas...

Reviews: