S64-B17 6-port switch with buffer power supply 

for 4 IP cameras

 

 

 

                                                                                                                                                 

 

        PL 

 

 

      Edition: 3 from 14.02.2019  

    Supercedes the edition: 2 from 01.03.2018                                     

EN**

 

 

 

Features

 

 

Uninterruptible power supply of 4 IP cameras (52 V DC)  

 

Switch 6 ports 
4 PoE ports 10/100 Mb/s  
(data transfer and power supply) 
2 ports 10/100Mb/s (UP LINK)  

 

30 W for each PoE port, supports devices complaint with 
the IEEE802.3af/at 

(PoE+) 

standard  

 

Approximate backup time: 5h 30min 

 

Metal enclosure 

– color white RAL 9003 

with battery space for a 17 Ah/12 V battery 

 

Supports auto-learning and auto-aging of 
MAC addresses (1K size) 

 

warranty 

– 2 year from the production date 

 

          

Example of use. 

 

CONTENTS 

1. Technical description.  

1.1 General description 
1.2 Block diagram 
1.3 Description of components and connectors  
1.4 Technical parameters 

2. Installation.  

2.1 Requirements  
2.2 Installation procedure 

3. Indication of the device operation 

3.1 LED indication of operating status 
3.2 Optical indication of the switch operation 

4. Operation and use.  

4.1 Overload or short circuit of the PSU output (SCP on)  
4.2 Disconnection of discharged battery 
4.3 Maintenance 

Summary of Contents for S64-B17

Page 1: ...ure color white RAL 9003 with battery space for a 17 Ah 12 V battery Supports auto learning and auto aging of MAC addresses 1K size warranty 2 year from the production date Example of use CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors 1 4 Technical parameters 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Indica...

Page 2: ...p time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 4 ports of the switch The UP LINK ports is used for connection of another network device e g recorder The LEDs at the front panel indicate the operation status description in the table 8 The switch is housed in a metal enclosure color RAL 9003 which can accommodate a 1x17 Ah 1...

Page 3: ...ch PoE 2 Switch mode buffer power supply unit 3 DC DC52115 converter 4 Output filter 5 Tamper micro switch terminals of tamper protection NC 6 Battery space for a 17 Ah 12 V battery 7 Power supply connector of the PSU L N Protective connector electric shock 8 BAT BAT battery output BAT red BAT black Fig 3 The view of the switch ...

Page 4: ...upply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 48 W Table 4 Electrical parameters Mains supply 200 240 V 50 Hz Current up to 0 7 A Supply power 55 W Output current at the PoE ports RJ45 4 x 0 6 A ΣI 1 A max Output voltage at the PoE ports RJ45 52 V DC Short circuit protection SCP and overload protection OLP 105 150 PSU ...

Page 5: ... and low voltage installations It is required to install an installation switch with a nominal current of min 3 A in the power supply circuits outside the power supply unit The device shall be mounted in confined spaces according to the environment class II with normal air humidity RH 90 max without condensation and the temperature from 10 C to 40 C The switch shall work in a vertical position tha...

Page 6: ...ctor Connect the ground wire to the clip marked by the earth symbol Use a three core cable with a yellow and green protection wire to make the connection Lead the cables to the appropriate clips through the insulating bushing of the connection board 4 Connect the power 230 V 5 Connect the battery mind the colours battery output V BAT cable red battery output 0V BAT cable GND black 6 Connect the ca...

Page 7: ...PoE PORTS 1 4 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 M s or 100 Mb s and data transmission OFF no connection ON the devi...

Page 8: ...e PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household waste According to the ...

Reviews: