FUNCTION
The KPLC7 PRC Load Controller together with the RM-0-10V
receiving module allows for changing the illumination level of
a 10-10V controlled LED fixture. It can also transmit and
receive UPB® (Universal Powerline Bus) digital commands over
the existing power wiring to remotely turn on, off, and dim
other UPB load control devices. No additional wiring is
required and no radio frequency signals are used for
communication.
In the default configuration, the buttons do not transmit UPB
commands but only control the LED fixture attached to the
RM-0-10V receiving module. The buttons can be changed to
transmit using the UPB configuration program UPStart.
Models
The KPLC7 can be mounted in any wall box that contains
neutral, line, load and ground wires. Available colors are
White, Black, and Light Almond.
Engraved Buttons
The KPLC7 has white backlit buttons engraved with the
designations of:
Scene 1, Scene 2, Scene 3, Scene 4
,
Off
,
and
an Up Arrow and Down Arrow.
Custom Engraved buttons
(model CEB) are available enabling you to tailor each button
for its particular use. Consult your dealer or our website
(www.pcslighting.com) for CEB ordering information.
MPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions
should always be followed, including the following:
1.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2.
Keep away from water. If the product comes in contact with
water or other liquid, turn off the circuit breaker and unplug
the product immediately.
3.
Never use products that have been dropped or damaged.
4.
Do not use this product outdoors.
5.
Do not use this product for other than its intended purpose.
Do not cover this product with any material when in use.
6.
SAVE THESE INSTRUCTIONS.
INSTALLATION
To install the KPLC7 module in a wallbox follow these instructions:
1.
Before installing the KPLC7 into a wall box, ensure that
power to the wall box has been disconnected by removing
the fuse or turning the circuit breaker off. Installing
products while the power is on may expose you to
dangerous voltage and may damage the product.
2.
Remove any existing wall plate and device from the wall box.
3.
Use wire nuts to securely connect the KPLC7
’s white wire to
the “Neutral” wire, the KPL
C7
’s black wire to the “Line” wire
and the red wire to the “Load” wir
e (see illustration below).
4.
Fit the KPLC7 into the wall box and secure with mounting
screws. Install the wall plate.
5.
Install the RM-0-10V receiving module as shown in the
wiring diagram.
6.
Restore power at the circuit breaker.