background image

 

Model KPLC7 

Keypad Load Controller

 

Installation Guide and 

Owner’s Manual 

 

 

 

The Inventors Of: 

 

19201 Parthenia St.  Suite J 
Northridge, CA 91324 
P: 818.701.9831 F: 818.701.1506 
pcssales@pcslighting.com 
www.pcslighting.com  

 

 

 

FUNCTION 

The  KPLC7  PRC  Load  Controller  together  with  the  RM-0-10V 
receiving module allows for changing the illumination level of 
a  10-10V  controlled  LED  fixture.  It  can  also  transmit  and 
receive UPB® (Universal Powerline Bus) digital commands over 
the  existing  power  wiring  to  remotely  turn  on,  off,  and  dim 
other  UPB  load  control  devices.  No  additional  wiring  is 
required  and  no  radio  frequency  signals  are  used  for 
communication. 

In the default configuration, the buttons do not transmit UPB 
commands  but  only  control  the  LED  fixture  attached  to  the 
RM-0-10V  receiving  module.  The  buttons  can  be  changed  to 
transmit using the UPB configuration program UPStart. 

Models  

The  KPLC7  can  be  mounted  in  any  wall  box  that  contains 
neutral,  line,  load  and  ground  wires.    Available  colors  are 
White, Black, and Light Almond. 

Engraved Buttons 

The  KPLC7  has  white  backlit  buttons  engraved  with  the 
designations of: 

Scene 1, Scene 2, Scene 3, Scene 4

Off

and 

an  Up  Arrow  and  Down  Arrow. 

  Custom  Engraved  buttons 

(model  CEB)  are  available  enabling  you  to  tailor  each  button 
for  its  particular  use.    Consult  your  dealer  or  our  website 
(www.pcslighting.com) for CEB ordering information. 

 

MPORTANT SAFETY INSTRUCTIONS 

When  using  electrical  products,  basic  safety  precautions 
should always be followed, including the following: 
 
 

1.

 

READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 

2.

 

Keep away from water.  If the product comes in contact with 
water or other liquid, turn off the circuit breaker and unplug 
the product immediately. 

3.

 

Never use products that have been dropped or damaged. 

4.

 

Do not use this product outdoors. 

5.

 

Do not use this product for other than its intended purpose. 
Do not cover this product with any material when in use. 

6.

 

SAVE THESE INSTRUCTIONS. 

INSTALLATION 

To install the KPLC7 module in a wallbox follow these instructions: 

1.

 

Before  installing  the  KPLC7  into  a  wall  box,  ensure  that 
power  to  the  wall  box  has  been  disconnected  by  removing 
the  fuse  or  turning  the  circuit  breaker  off.    Installing 
products  while  the  power  is  on  may  expose  you  to 
dangerous voltage and may damage the product. 

2.

 

Remove any existing wall plate and device from the wall box. 

3.

 

Use wire nuts to securely connect the KPLC7

’s white wire to

 

the “Neutral” wire, the KPL

C7

’s black wire to the “Line” wire

 

and the red wire to the “Load” wir

e (see illustration below). 

4.

 

Fit  the  KPLC7  into  the  wall  box  and  secure  with  mounting 
screws.  Install the wall plate. 

5.

 

Install  the  RM-0-10V  receiving  module  as  shown  in  the 
wiring diagram. 

6.

 

Restore power at the circuit breaker. 

 

           

 

 

Reviews: