background image

For correct operation & installation, it is essential to observe these instructions.

JUL2020

WMTS103:2016

Certificate No. WM 74593 

Australian Certification 

Services

User Guide

Filtration & Ultraviolet All-in-One Unit

Hybrid Series

Summary of Contents for HYBRID G12

Page 1: ... operation installation it is essential to observe these instructions JUL2020 WMTS103 2016 Certificate No WM 74593 Australian Certification Services User Guide Filtration Ultraviolet All in One Unit Hybrid Series ...

Page 2: ...System 4 Positioning Your System 5 Power Surge Protection 5 Installation Requirements 6 Initial Installation Procedure 8 Operation 12 Radfire UV Unit 12 Lamp Ballast Operation 12 Lamp Ballast Specifications 12 Lamp Ballast Diagram 13 Replacement Parts Guide 14 Cartridge Replacement Procedure 15 Lamp Replacement Procedure 16 Quartz Sleeve Maintenance Replacement Procedure 18 Troubleshooting Guide 2...

Page 3: ...s system will effectively treat water depending on the required UV dosage and existing water quality The system is designed for mains and rainwater supply but can be used in other situations For other types of water supply please contact your local Puretec stockist or call our Puretec Customer Service Helpline on 1300 140 140 Australia or 0800 130 140 New Zealand The Puretec Hybrid system cartridg...

Page 4: ...oving your Hybrid system from its carton you should check all the components especially the lamp to ensure all are present and have not been damaged in transportation Depending on your model you should have Remove all the packing materials prior to use As a responsible manufacturer we care about the environment We urge you to follow the correct disposal procedure for your product and packaging mat...

Page 5: ... a fuse non replaceable to protect the circuit The fuse is not a lightning arrester and may not protect the Radfire if lightning or a very powerful surge hits the unit A suitable surge protection device has been provided with this product Puretec recommends the use of a surge protector the one supplied or otherwise or warranty may be voided WARNING The Arlec power surge protector that is provided ...

Page 6: ...sure the water supply flow rate does not exceed the rated maximum of the Hybrid system Ensure the electrical power supply to the Hybrid system is sufficient allowing for other appliances that may be connected to the circuit e g pump and ensuring it is surge protected and protected against brown outs If in doubt please consult a qualified electrician Use unions at pipe connections to enable easy re...

Page 7: ...ssociated with UV systems and if this is deemed a problem we recommend installing a temperature management valve which is installed inline immediately after the system and releases water periodically Ordering code is RI TMS4 Note This water filtering appliance should only be installed by a fully qualified licenced plumber Installation Note A water filter system tap like any product has a limited l...

Page 8: ... ensure the quartz sleeve is intact within the Radfire UV Unit 2 Locate a suitable position for the Hybrid system remembering to allow 120mm under units with 20 housings and 700mm clearance above the unit for cartridge and lamp changes A power outlet is required allow min 120mm clearance from the ground 700mm clearance 700mm clearance HYBRID G6 G8 MODEL HYBRID G7 G9 MODEL Installation Procedure Fi...

Page 9: ...l in One Unit allow min 120mm clearance from the ground 700mm clearance 700mm clearance HYBRID G12 MODEL HYBRID G13 MODEL Installation Procedure allow min 120mm clearance from the ground 700mm clearance 700mm clearance HYBRID R1 R3 MODEL HYBRID R2 R4 MODEL ...

Page 10: ...ng provisions 2 key holes at the front and rear of the bracket Use the template provided to mark the desired position on the wall where the fixings are required to go 4 Drill the holes and install the anchors fixing anchors not included 5 Position the Hybrid Hybrid G Position on the wall and tighten the fixings to hold the system securely to the wall Fig 2 HYBRID R10 MODEL HYBRID R11 MODEL allow m...

Page 11: ...inium nut end Connect the lamp connector to the pins on the lamp Do not let go of the lamp until the lamp is connected to the socket see Fig 7 Never touch the quartz glass and lamp surface as marks or fingerprints may interfere with UV transmission If lamp is soiled please clean lamp with an alcohol based cleaner 10 Put safety cap on the aluminium nut end Connect the ground wire to the chamber as ...

Page 12: ...rm for 7 days press and hold on the silver button until delay appears on the screen Lamp Ballast Specifications AC 240V 50Hz Lamp Power 35W 95W Lamp Current 0 8A 0 9A Ambient Temperature 4 40 C Lamp Rated Life 365 days Caution Ground the ballast casing to avoid possible high voltage shock hazard Operation Allow two minutes for the UV lamp to reach full intensity before starting water flow On a new...

Page 13: ...13 HYBRID SERIES Filtration Ultraviolet Disinfection All in One Unit Aluminium Nut Water Outlet O Ring Quartz Sleeve UV Stainless Steel Chamber O Ring Water Inlet Fig 5 Lamp Ballast Diagram ...

Page 14: ...ndards use genuine Puretec replacements Replacement Parts Stage 1 Cartridge Stage 2 Cartridge Stage 3 Cartridge UV Lamp Quartz Sleeve HYBRID G6 R1 PL05MP1 DP10MP1 N A RL6 RQS6 HYBRID G7 R2 PL05MP2 DP10MP2 N A RL6 RQS6 HYBRID G8 R3 PL20MP1 PX01MP1 N A RL6 RQS6 HYBRID G9 R4 PL20MP2 PX01MP1 N A RL6 RQS6 HYBRID G12 R10 PL05MP1 CB05MP1 PX01MP1 RL6 RQS6 HYBRID G13 R11 PL05MP2 CB05MP2 PX01MP2 RL6 RQS6 Re...

Page 15: ...silicone lubricant or similar 5 Remove all packaging from new filter cartridges and insert into housing bowls making sure cartridges are properly seated over the spigot in base of the bowls Remember to record the model number of the cartridges you use install date 6 Hold bowls upright while screwing in the housings Make certain that the spigot in the housing heads is located centrally to the cartr...

Page 16: ...o of the lamp until the lamp is connected to the socket see Fig 6 Never touch the quartz glass and lamp surface as marks or fingerprints may interfere with UV transmission If lamp is soiled please clean lamp with an alcohol based cleaner 4 Secure the lamp connector on the aluminium nut end Connect the ground wire to the chamber Plug in power connector the RED LED will be illuminated when the lamp ...

Page 17: ... been reset for a further 12 months 7 If you have the Hybrid G model close and lock the lid Note Your cabinet comes with 2 keys for your convenience Please store them safely Note Lost or misplaced keys are not covered by warranty We recommend replacing UV lamp annually to ensure high sterilising rate with best water quality Always keep UV lamp on as power fluctuation will shorten the service life ...

Page 18: ...ium Nut 3 Slowly remove the UV Lamp from the chamber 4 Unscrew and remove the Aluminium Nut on the top of the chamber Now remove the Aluminium Nut from the bottom of theStainless Steel Chamber securing the Spring and Quartz Sleeve Important Be aware that the water within in the chamber will be discharged through the bottom of the Stainless Steel Chamber once the bottom Aluminium Nut is removed Imp...

Page 19: ...of the Aluminimum Nut at the top of the chamber Connect the lamp connector to the pins on the White Lamp Socket Do not let go of the lamp until the lamp is securely connected to the socket Never touch the quartz glass and lamp surface as marks or fingerprints may interfere with UV transmission If lamp is soiled please clean lamp with an alcohol based cleaner 10 Put lamp connector on the Aluminium ...

Page 20: ... pass through the whole unit Turn on a downstream tap to let the water flow through the unit for 2 3 minutes to release any air and impurities from system 12 If you have a Hybrid G model close and lock the lid Your cabinet comes with 2 keys for your convenience Please store them safely Note Lost or misplaced keys are not covered by warranty Maintenance Procedure 7 8 Replacing UV Lamp valve IN OUT ...

Page 21: ...from area of UV chamber Condensation of moist air on cold chamber slow accumulation O ring damaged deteriorated or incorrectly installed Lamp sleeve assembly not properly installed too tight or not tight enough Control humidity or relocate unit Inspect and replace if deteriorated Check O rings are in place Tighten assembly hand tight System is operating but water tests reveal bacterial contaminati...

Page 22: ...ed O rings dry Filter cartridge not centered Remove the sump wipe the O ring and threads clean Ensure the O ring is fitted properly then reinstall Lubricate O rings with suitable sealant Remove sump check for cartridge damage re assemble ensuring cartridge is centered Red lamp blinks and buzzer sounds Lamp has reached or nearing the maximum lamp life Lamp is disconnected or faulty Replace lamp on ...

Page 23: ...luding chargeable inspection and labour costs incurred All installation and service work should be completed by qualified tradespeople Faulty operation due to unqualified persons will result in voided warranty coverage Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This w...

Page 24: ......

Reviews: