User Guide

Inline Undersink Water Filter System

Puretec  X3 / X4

For correct operation & installation it is essential to observe these instructions.

Summary of Contents for X3

Page 1: ...3497 Licence No WM 74617 Australian Certification Services NOV2018 User Guide Inline Undersink Water Filter System Puretec X3 X4 For correct operation installation it is essential to observe these instructions ...

Page 2: ...er systems are designed to run economically for many years and this is dependant on the initial installation and periodical maintenance Flush systems for 10 minutes after any period of non use more than 2 days For a period of non use of 2 weeks or more it may be necessary to replace cartridge Cartridge Replacement To maintain the high quality of the purified water the cartridges need changing ever...

Page 3: ...and a suitable place where water spillage will not cause damage Location should not be in direct sunlight 2 Isolate water supply and cut copper pipe ready to install the adaptor ballvalve 3 Connect the ballvalve to the multivalve with a piece of white tubing 4 Choose the best position for the faucet taking into consideration height of jugs etc and also the drainage of any spills Then drill a 012 5...

Page 4: ...nsure you reset the LED reminder light by removing replacing the battery from the rubber seat Please refer to page 6 for a detailed diagram 6 Restore water supply 7 Check for leaks rectify any before leaving the unit After installing cartridges flush unit for 5 10 minutes Use Guidelines Do not allow exposure to temperatures below 0 C Protect from freezing Maximum operating temperature 38 C Maximum...

Page 5: ...be Nut and Ferrule 7 Tube Insert 8 Faucet Lock Nut and Washer 9 Black Plastic Washer 10 LED Faucet 1 Cut the tube square and push in to the tube stop For metal tube remove burrs and chamfer tube end to prevent O Ring seal being damaged DISCONNECTION PROCEDURE 4 Push collet against body and slide tube out of fitting 2 Fitting grips before it seals Ensure tube is pushed in to tube stop HOW TO USE QU...

Page 6: ...ing cartridges 5 Red light flashes indicates your cartridges are due to be changed usage has exceeded 3 000 minutes or 12 months Please change the battery when changing the cartridges Positive side up Negative on the PCB 4 Blue light flashes during normal operation Faucet utcheon O Ring Display Battery Seat Circuit Board Battery CR2032 Base Upholder Counter Top Washer 1 4 mpression Nut 1 4 Tube Co...

Page 7: ...tic water treatment appliance Standards AS NZS3497 for the following water treatment processes Class Treatment type Function Pass I Microbiological Status Will stop bacteria increasing but will not remove them unless II a is passed N A Bacteriostatic II Microbiological Treatment II a Bacteria Removal Will remove or inactivate bacteria N A II b Virus Removal Will remove or inactivate virus N A II c...

Page 8: ... claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred WARRANTY AUSTRALIA This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This warranty is provided in addition to other rights and remedies you have under law Our goods come with guarantees wh...