Summary of Contents for Squid Go

Page 1: ...ACTIVE COLD COMPRESSION DEVICE COLD PACK O V E R T H E C O U N T E R U S E REUSABLE INSTRUCTIONS FOR USE ...

Page 2: ...GO DEEP ...

Page 3: ...ION AND CHARGING 6 OPERATING INSTRUCTIONS 7 AVAILABLE SQUID GO WRAPS 9 QUICK START GUIDES ALL MODELS 11 22 CLEANING 23 TROUBLESHOOTING 25 INFORMATION ON LI ION BATTERIES 27 INFORMATION ON ELECTROMAGNETIC COMPATIBILITY 29 GUIDANCE AND MANUFACTURER S DECLARATION 30 WARRANTY 34 SUPPORT BACK COVER Read instructions prior to use Manufactured for Portable Therapeutix Stafford TX i ...

Page 4: ...fully before use This manual contains information contraindications and warnings that must be observed to ensure safe operation and maintain the Squid Go in a safe condition The Squid Go MUST be used in accordance with the instructions PACKAGE COMPONENTS ACCESSORIES ABOUT THIS MANUAL FIGURE 1 PACKAGE COMPONENTS ACCESSORIES PUMP COMPONENTS WRAP COMPONENTS Reusable Cold Gel Pack GEL PACK Potential p...

Page 5: ...trol the amount of compression and the treatment time For user comfort there are 4 modes Table 1 which have different peak pressures and time on and time off cycles The total duration of treatment time is 15 minutes TECHNICAL DESCRIPTION D E F A U L T MODE PEAK PRESSURE ON 1 2 3 4 30 50 70 85 mmHG mmHG mmHG mmHG 0 0 0 0 mmHG mmHG mmHG mmHG 40 35 30 25 seconds seconds seconds seconds 20 25 30 35 se...

Page 6: ...ve Cold Compression device and Cold Pack for OTC use is indicated for the temporary relief of minor muscle aches and pains The compression device is indicated for temporary increase in circulation of the treated areas in people who are in good health and simulates kneading and stroking of tissues using an inflatable garment The Cold Pack is indicated for localized therapy in situations where cold ...

Page 7: ...lobulins which are proteins Thrombosis blood clots in the brain heart or other blood vessels Aneurysm enlargement of a blood vessel artery caused by a weak artery wall Vascular disease which includes narrowing of blood vessels or thickening of blood vessel walls causing loss of blood flow Diabetes blood glucose disease High blood pressure Compromised local circulation blood circulation that is not...

Page 8: ... case of ingestion seek medical care In case of contact with eyes wash with water and seek medical care The Squid Go Pump is not waterproof Do not apply a direct stream of any liquid onto the Squid Go Pump do not submerge it and do not allow any liquid to pool on the surface of the front panel Attempting to self service any part of the Squid Go will void the warranty and may cause injury Avoid con...

Page 9: ... charge will require 8 hours 2 When the battery charge indicator shows empty battery after the unit is turned on the unit will have sufficient power for up to 3 treatments Flashing empty battery symbol indicates drained battery and the unit will not start The unit can then be used while plugged into a wall outlet If battery is completely drained battery icon flashing the unit may require 5 10 minu...

Page 10: ...er normal use conditions the Squid Go Cold Gel Pack recommended life cycle is one year for maximum efficacy 3 To obtain a replacement Gel Pack contact Portable Therapeutix Customer Service NOTE The Squid Go is reusable WEARING THE WRAP 1 Remove the Cold Gel Pack from the freezer and place within the compression Wrap aligning the Velcro on the Wrap with the Velcro on the Gel Pack and secure the Vel...

Page 11: ...ct an operation mode by pressing the MODE selection button The selected mode will appear on the display as a number from 1 to 4 1 for low pressure and 4 for high pressure Always start using in mode 1 Use modes 2 3 4 to increase pressure until a comfortable pressure is achieved The mode may be changed during use by pressing the START button for half a second When the screen begins to blink press th...

Page 12: ... ANKLE WRAP ELBOW WRAP BACK WRAP AVAILABLE SQUID GO WRAPS AND GEL PACKS Denotes the Wrap is available in multiple sizes 9 ...

Page 13: ... SHOULDER WRAP LEG WRAP WRIST WRAP KNEE WRAP 10 ...

Page 14: ...foot wearing sock in center of Wrap with writing on right side of the foot and heel at back edge of the Wrap 1 2 3 4 If possible keep knee and ankle aligned at right angles F s C s t c 5 6 7 8 Velcro the Cold Gel Pack to the inside of the Ankle Wrap FASTE KNEE ANKLE AT 90O WRITING ON WRAP S INTERIOR ...

Page 15: ... tightness to your comfort level Pull the straps on each side of your foot up and towards knee Wrap the strap with the Squid Go logo around your shin and fasten Attach Connector Tube to Pump and Wrap Begin 15 Minute Treatment 5 6 7 8 e inside FASTEN NEE ANKLE T 90O WRITING ON WRAP S INTERIOR ...

Page 16: ...ezer for 12 hours prior to use 12 HOURS Place Barrier Cloth over elbow Squid Go also works over clothing Position elbow in the center of the Wrap s interior with the Connector pointing towards wrist 1 2 3 4 5 6 Attach Cold Gel Pack inside of Wrap using Velcro ...

Page 17: ...h Connector Tube to Pump and Wrap Begin 15 Minute Treatment 2 RS hing w in the Wrap s the inting Fasten the larger strap around bicep Then fasten the smaller strap around forearm Adjust tightness as needed 5 6 Wrap ...

Page 18: ... 5 6 7 8 Place Gel Pack in freezer for 12 hours prior to use Remove Gel Pack from freezer and fasten its Velcro strap Attach Cold Gel Pack inside of Wrap using Velcro Place Barrier Cloth over knee Squid Go also works over clothing 12 HOURS ...

Page 19: ...16 Place Wrap on knee and fasten the lower strap first Fasten the top strap snugly Attach Connector Tube to Pump and Wrap Begin 15 Minute Treatment 5 6 7 8 Gel m and s trap Wrap th over lso ing 2 RS ...

Page 20: ...T GUIDE 1 2 3 4 5 6 7 Place Gel Pack in freezer for 12 hours prior to use Wrap Squid Go around the leg 12 HOURS Place Barrier Cloth over leg Squid Go also works over clothing Attach Cold Gel Pack inside of Wrap using Velcro ...

Page 21: ...g the Velcro panels Attach Connector Tube to Pump and Wrap Begin 15 Minute Treatment 5 6 7 The Squid Go Leg Wrap can be positioned in a variety of ways to better treat affected areas 2 RS loth Go also thing Wrap CALF SHIN QUADRICEP HAMSTRING KNEE ...

Page 22: ...s prior to use Before putting on Wrap fasten the straps on either side of the Connector Tube together to create an armhole 12 HOURS Attach cold Gel Pack inside of Wrap using Velcro W s t o SHOULDER STRAP FRONT FI Insert arm with the connector pointing towards wrist Wear Wrap over clothing ...

Page 23: ...and Wrap 2 RS Wrap Two straps are behind you Fasten the shorter strap under the arm receiving treatment Wrap the longer strap around the torso under the opposite arm DER STRAP RONT SECOND FIRST Begin 15 Minute Treatment with tor wards Wrap ng ...

Page 24: ...E 1 2 3 4 5 6 7 Place Gel Pack in freezer for 12 hours prior to use Place thumb through the hole in the Wrap 12 HOURS Place Barrier Cloth over wrist Squid Go also works over clothing Attach Cold Gel Pack inside of Wrap using Velcro ...

Page 25: ...22 Fasten Wrap around the wrist snugly using the Velcro panels Attach Connector Tube to Pump and Wrap Begin 15 Minute Treatment 5 6 7 2 RS th over lso ing Wrap THUMB HOLE ...

Page 26: ...k Wipe dry following each use Cloth Machine wash warm Tumble dry low Do not bleach Do not dry clean Avoid the use of fabric softeners CAUTION The Squid Go Pump is not waterproof Do not apply a direct stream of any liquid onto the Squid Go Pump do not submerge it and do not allow any liquid to pool on the surface of the front panel CLEANING Temperature 59 F 104 F 15 C 40 C Humidity 30 RH 80 RH OPER...

Page 27: ... unit and AC adapter in a safe cool and dry place when not in use Wrap and Connector Tube must be dry before storing in a cool and dry place The Wrap and Connector Tube may be rolled prior to storage The Cold Gel Pack should be wiped dry and stored in a cool dark pace When storing for longer than two weeks place the Cold Gel Pack inside a sealed plastic container or bag prior to storing to minimiz...

Page 28: ... no visible reason for a leak is apparent and error signal persists contact customer support ERROR WHATDOES ITMEAN WHATCAN IDO The Pump motor is not working and no compression Contact customer service WHATDOES ITMEAN WHATCAN IDO The Pump pressure exceeded the maximum pressure of the mode This can occur if the user applies external pressure to the Wrap Any other over pressure would also indicate a ...

Page 29: ...sitioned against the body and secured using the Velcro closure Make sure Wrap is fully deflated prior to wearing Make sure the Tube Connector is connected to the Pump control unit and the Wrap Inspect the Wrap and Tube Connector for air leak Battery is drained and the AC adapter is not connected WHATDOES ITMEAN WHATCAN IDO Gel Pack is not cold or is missing Make sure that Gel Pack is placed in a f...

Page 30: ... hazards only in accordance with UL 60601 1 Powered by Direct Current Type BF Applied Parts IP 21 Classified Class II equipment SQUIDACTIVECOLDCOMPRESSIONDEVICE COLDPACK MODEL ONE 5V 1A IP 21 Operating Instructions Do not use this device if you have any of the conditions listed in the User Manual Manufacturer Portable Therapeutix LLC 4254 Bluebonnet Drive Stafford TX 77477 USA DANGER Failure to ob...

Page 31: ...range of 32 F 104 F 0 C 40 C 3 Handle damaged or leaking batteries with care personal injuries may result from mishandling 4 Recycling may be required for your region consult local recycling facility for more information WARNING 1 Do not immerse Squid Go Pump in water 2 Do not store Squid Go Pump in temperatures exceeding 104 F 40 C and in direct sunlight 3 Li ion batteries have a predetermined op...

Page 32: ...t parts for internal components may result in increased emissions or decreased immunity of the equipment or system 1 Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the Accompanying Documents 2 Portable and Mobile RF Communications Equipment can affect Medical Electrical Equipment 29 ...

Page 33: ...GROUP 1 COMPLIANCE CLASS B COMPLIANCE CLASS B COMPLIES The Squid Go is suitable for use in all establishments including domestic and those directly connected to the public low voltage power supply network that supplies buildings used for domestic purposes RFEMISSIONS CISPR11 HARMONICS IEC61000 3 2 FLICKER IEC61000 3 3 EMISSIONSTEST ElectromagneticEnvironment Guidance WARNING The equipment or syste...

Page 34: ...Mains power quality should be that of a typical commercial or hospital environment VOLTAGE DIPS DROPOUTS IEC61000 4 11 95 Dipfor 0 5Cycle 60 Dipfor 5Cycles 30 Dipfor 25Cycles 95 Dipfor 5Seconds 95 Dipfor 0 5Cycle 60 Dipfor 5Cycles 30 Dipfor 25Cycles 95 Dipfor 5Seconds Mains power quality should be that of a typical commercial or hospital environment If the user of the Squid Go requires continued o...

Page 35: ... to 80MHz D 3 5 E1 Sqrt P 80 to 800MHz D 7 E1 Sqrt P 800MHz to 2 5 GHz where P is the max power in watts and D is the recommended separation distance in meters Field strengths from fixed transmitters as determined by an electromagnetic site survey should be less than the compliance levels V1 and E1 Interference may occur in the vicinity of equipment containing a transmitter IMMUNITY TEST IEC60601 ...

Page 36: ...ower of the communications equipment SQUID GO IS INTENDED FOR PERSONAL USE USE OF SQUID GO IN A COMMERCIAL SETTING OR ENVIRONMENT INCLUDING BUT NOT LIMITED TO PHYSICAL THERAPISTS ATHLETIC TRAINERS AND HOSPITALS WILL IMMEDIATELY VOID THE WARRANTY OF THE PUMP WRAP TUBE CONNECTOR GEL PACK AND BATTERY CHARGER 0 01 0 11667 0 11667 0 23333 0 1 0 36894 36894 0 73785 1 1 1667 1 1667 2 3333 10 3 6894 3 689...

Page 37: ...ortable Therapeutix will at its option either repair or replace the Wrap or Tube If Portable Therapeutix elects to replace the Wrap or Tube it may do so with a new or reconditioned Wrap or Tube Your original one year warranty period shall be extended by the number of days that the Wrap or Tube is in the possession of Portable Therapeutix until it ships the repaired or replacement Wrap or Tube back...

Page 38: ...d you are responsible for any damages or loss incurred during shipping other than any damage that was the result of your warranty claim WARRANTY LIMITATIONS AND EXCLUSIONS THESE WARRANTIES REPLACE ALL OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE PORTABLE THERAPEUTIX MAKES NO EXPRESS WARRANTIES BEYO...

Page 39: ...GO DEEP ...

Page 40: ...N 3 10 30 2017 SUPPORT For all servicing questions or complaints in the U S visit Squid Go Support at www SquidGo com support or call 281 823 9600 Portable Therapeutix LLC 4254 Bluebonnet Dr Stafford TX 77477 ...