Page 1: ...1 SprayMaster System User Manual www PyranhaInc com Houston Texas System_Manual_2020 indd 1 System_Manual_2020 indd 1 12 23 20 10 18 AM 12 23 20 10 18 AM ...

Page 2: ...2 SprayMaster System User Manual www PyranhaInc com Houston Texas System_Manual_2020 indd 2 System_Manual_2020 indd 2 12 23 20 10 18 AM 12 23 20 10 18 AM ...

Page 3: ...lease complete and mail in the attached registration within 30 days of purchase or go to www pyranhainc com and register online to ensure that your system will be covered under our One 1 Year System Top Warranty pump timer and motor Warmest Regards The Pyranha Family Pyranha Inc Attention Customer Service 6602 Cunningham Road Houston Texas 77041 Company Individual Name Address City State Zip Phone...

Page 4: ...4 SprayMaster System User Manual www PyranhaInc com Houston Texas System_Manual_2020 indd 4 System_Manual_2020 indd 4 12 23 20 10 18 AM 12 23 20 10 18 AM ...

Page 5: ...lid 4 Carefully drop float through top of matching large hole Make sure float line isn t pinched between the drum lid and system disk 5 Insert supplied bolts through the bolt holes near the edges of the plastic disk and secure to the drum top Tighten by hand to hold system disk in place and then use wrenches to finish tightening Don t over tighten as the plastic system disk can crack 6 Check float...

Page 6: ...mer Pt 008MCRTIME Float Pt 006FLO Pressure Gauge Pt 006PG 45 Degree Fitting Pt 00745DFMPF Reducer Bushing Pt 007RB Check Valve 3 psi Pt 007CV3 Brass Cross Female Thread Pt 007BC Male Discharge Elbow 1 4 Pt 007E1 Pressure Regulating Valve Pt 007BPV Check Valve 25 PSI Pt 007CV25 Intake Filter Pt 006IF Intake Elbow 3 8 Pt 007E3 Pyranha Pyranha 12 6 3 9 10 CIRCUIT BREAKER TANK EMPTY AUTO OFF TEST 15 4...

Page 7: ...intake filter through the lid and PVC circle and connect it to the pump suction inlet elbow Figure 2 3 Insert the check valve assembly through the lid and PVC circle and connect it to the pressure regulating valve Figure 2 4 Place the lid on the drum making sure the black float with nylon line passes through the cut out with all lines hanging freely 5 Remove the pressure gauge from its box and scr...

Page 8: ... diagrams as a guide Figure 4 run the inch nylon tubing on the ground around the stall area to be treated beginning at the tank 2 Using supplied tubing cutter cut the tubing squarely to ensure airtight connections at each spray nozzle System_Manual_2020 indd 8 System_Manual_2020 indd 8 12 23 20 10 18 AM 12 23 20 10 18 AM ...

Page 9: ... Do not install above fifteen 15 feet from the floor Use cable wire if necessary Make sweeping turns with the tubing around corners to avoid kinking 5 After all the spray nozzles have been installed run the beginning of the tubing from the discharge elbow on the brass cross assembly Figure 3 Tighten with a wrench Leave four 4 feet of slack in the line to allow for easy shifting of the lid to add i...

Page 10: ...ting correctly with no leads at the tubing connections flip the toggle switch to OFF and disconnect the electrical cord from the outlet Close the timer lid 11 Carefully lift the drum lid and shift it to the side of the drum top Add the entire contents of the insecticide concentrate to the drum and finish filling with clean water to four 4 inches from the top of the drum Replace the lid on the drum...

Page 11: ...5 Set the run duration selector switch to the length of spray time desired When you are first starting the system we recommend setting the timer to operate six 6 times a day for 45 seconds each time When the area is under satisfactory control 10 to 14 days cut back on the number of spray cycles and duration time to maintain control NOTE System will run continuously when the toggle switch is in the...

Page 12: ...d water NOTE If flushing out the drum consider collecting the insecticide at the bottom of the drum prior to cleaning and spreading it on your manure pile 5 Fill the drum about halfway with water Put the lid back on the drum being careful to not pinch the float line or tubing Plug the system to the power source 6 Open the bleed valve and hold in the drum Flip the toggle switch to TEST Once the liq...

Page 13: ...ggle switch to OFF Unplug the sys tem from the power source 3 Allow the nozzle tubing to drain for sever minutes to empty as much liquid as possi ble Be sure the intake filter stays out of any liquid remaining in the drum 4 If the drum freezes during the winter you will need to stir any contents before reusing Re connecting the SprayMaster System after Winterizing 1 After stirring the contents of ...

Page 14: ... 128 oz gives you the number of gallons of liquid used each week A 45 second cycle dispenses 1 ounce of insecticide per spray nozzle The following is for firing for 45 seconds 6 times a day at 190 P S I Number of Nozzles in Facility Consumption Rate 30 Gallon System 50 Gallon System 6 Nozzles 1 97 gal wk 15 weeks 25 weeks 8 Nozzles 2 62 gal wk 11 weeks 19 weeks 10 Nozzles 3 28 gal wk 9 weeks 15 we...

Page 15: ...ce the intake filter 006IF Motor seems to be bogged down and system shuts off causing motor to overheat 1 The Pressure Regulating Valve is completely closed off 2 Check valve is bad 3 Bad motor and or pump 1 Turn Pressure Regulating Valve counterclockwise until the pressure gauge is between 190psi 210psi 2 Purchase new check valve 007CV25 3 Replace motor and or pump System only runs with the extra...

Page 16: ...NG 8 NOZZLES 004SNA1NPNS SPRAY NOZZLE ASSEMBLY 1 4 NICKLE PLATED BARREL NICKLE SILVER TIP 004SNANPNSKIT SPRAY NOZZLE ASSEMBLY KIT 5 1 4 NOZZLE ASSEMBLIES 100 TUBING 004NTUNUPKIT TUNE UP KIT 2 1 4 NOZZLES 5 SPRAY TIPS 1 INTAKE FILTER WITH TUBING 001HP55 PYRANHA 1 10HP CONCENTRATE FOR 55 GALLON SYSTEM 2 5 GAL 001HPS30 PYRANHA 1 10HPS CONCENTRATE FOR 30 GALLON SYSTEM 2 5 GAL 001ODAWAYC PYRANHA ODAWAY...