background image

Part No.  95258   2-15-10  

MP50

CONTROLLER/COMPRESSOR

MODEL

PATENT PENDING

O

U

asics

Manual

Instruction

P.O. Box 3726   Ann Arbor, MI  48106-3726  USA

1-800-624-2026    Fax (734) 995-1170

info@qedenv.com    www.qedenv.com   

Summary of Contents for MP50

Page 1: ...art No 95258 2 15 10 MP50 CONTROLLER COMPRESSOR MODEL PATENT PENDING O U asics Manual Instruction P O Box 3726 Ann Arbor MI 48106 3726 USA 1 800 624 2026 Fax 734 995 1170 info qedenv com www qedenv co...

Page 2: ......

Page 3: ...MP50 Controller Optional MP30 Drawdown Meter Well Cap Tubing Pump Air Supply Pump Discharge Well Wizard Bladder Pump R MP50 Basic Setup...

Page 4: ...icroPurge Mode Using CPM Sampling Use with the MP30 Level Sensing Water Level Meter ID Mode User Time Set MN Mode MP50 Battery Troubleshooting MP50 Specifications QED Service Contacts QED Warranty App...

Page 5: ...operate the controller within the pres sure limits could result in failure Read all operating instructions before operating the MP50 controller Warning Do not disassemble the pneumatic pump while it...

Page 6: ...et MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D E CYC...

Page 7: ...pump is Refilling or Discharging Cycles per minute setting The mode the controller is in Refill time setting in seconds Time remaining in the cycle ID for time settings Abbreviations CPM MP ID HELD MN...

Page 8: ...d for each well ID Time Set Mode Operation Quickly recalls pre determined settings for each well by specifying a 3 digit ID Level Delay Interface The controller plugs into the optional MP30 MicroPurge...

Page 9: ...dy flow stream is achieved Press keys to set the desired purge flow rate To collect samples continue purge flow or use key to directly control sample flow and pause Quick Start Attach Red Positive cab...

Page 10: ...ate the refill time should be set long enough to achieve the maximum volume of air bubbles on each pump cycle and the discharge time should be set long enough to ensure that the air has stopped bubbli...

Page 11: ...stored with its lid closed Opening Display The opening display is shown for 5 seconds and displays the controller name the version number and the battery voltage as shown in Figure 1 Figure 1 shows th...

Page 12: ...D mode Figure 2 MP50 MicroPurge Mode Using CPM The MP50 introduces a revolutionary simpler way to control bladder pump flow rate and achieve the low flow method used by experts Up down arrow keys are...

Page 13: ...And the MP10 assigns a unique identification value to each setting the ID value which can be directly set during later sampling events MP displayed in the lower left corner of the display indicates Mi...

Page 14: ...remind you that the controller is in a paused state Figure 3 shows an example of the MP50 in MP mode but HELD in the Sample state I I Figure 3 MP50 Held State MP mode MicroPurge Basics Controller MP M...

Page 15: ...Drawdown Control The MP50 may optionally be used with the MP30 MicroPurge Drawdown Water Level Meter See Figure 4 for an example of the MP50 in MP mode with the controller in a level paused state enac...

Page 16: ...Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D E D E 1 800 624 2026 micropurge com O U ED asics CONTROLLER MP10 MicroPurge Mode Quick Guide 3 AA BATTE...

Page 17: ...ra tion so as to maintain drawdown at the set level When the water level drops below the probe the MP30 sends a signal to the MP50 to pause pumping Both the MP50 and the MP30 give visual signals and t...

Page 18: ...Set MN Manual Time Set LVL LevelShutoff CYCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 103 10 0 MP CPM4 05 0 D E 14...

Page 19: ...YCLE I I MODE CPM Value Flow Value Flow Value Hold Sample Cycle Start Stop ID MN MP Battery Mode CPM ID Time Refill Discharge 00 1 10 0 MN 05 0 D E 15 Note changes in time settings that are entered wh...

Page 20: ...to select the digits of the refill and discharge time settings found at the rightmost positions on the display The UP and DOWN keys are used to adjust the digit value up or down By selecting and adjus...

Page 21: ...rged when in MP mode Temperature below 10 F Warm controller Air not cycling through controller Throttle turned too low Turn throttle clock wise to produce pressure Air source not delivering air Verify...

Page 22: ...n to 100 humidity Circuitry protected against transient surges introduced from improper battery installation or switch connections 16 x 13 x 6 5 21 lbs Structural Resin 6 keys LCD display 32 character...

Page 23: ...yers exclusive remedy for breach of said warranty shall be as follows if and only if Q E D is notified in writing within applicable warranty period of the existence of any such defect in the said prod...

Page 24: ...repair by others is made with the written consent of Q E D If any product covered hereby is actually defective within the terms of this warranty Purchaser must contact Q E D for determination of warra...

Page 25: ...13 5 13 12 5 12 11 5 11 10 5 9 5 9 8 5 8 7 5 7 6 5 6 5 5 5 10 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38...

Page 26: ...P O Box 3726 Ann Arbor MI 48106 3726 USA 1 800 624 2026 Fax 734 995 1170 info qedenv com www qedenv com...