Water, Vibration, and Oil Resistant LED Work Lights

QML/ QMHL

QML series

QMHL series

QML

-

150

-

D

-

24

[Model number]

[Product length]

[Mount bracket]

[Voltage]

|

|

|

|

• QML - Anti-glare

• QMHL - High illumination

• 150 - 150mm

• 250 - 250mm

• D : No bracket

• K : Tilt bracket

• MF : Tilt and swivel bracket

• 24 - DC24V

67

69K

60

30

Thank you for purchasing Qlight’s products. Please read this user manual carefully 

prior to installation and operation to ensure safe and correct use.

Precautions for Safety  

Failure to follow the instructions below may cause a loss of life or serious physical injury.

1. Please remove any objects that can interrupt ventilation around the product. 

2. Please turn off the power of the product immediately if it fails to operate properly. 

3. Carefully wire the product according to each product’s specification. 

4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product. 

5. Do not apply excessive force/impact to the product. 

6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.

Precautions for Correct Use 

Failure to follow the proper instructions may cause damage to property, the product, and or malfunction of  the 

product that would void the warranty. 

1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)

2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection 

    ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury, 

    malfunction or damage to the product.)

3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to 

    follow these instructions may lead to fire, electric shock, or product damage.)

4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)

5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to 

    follow this may cause damage to property, fire, electric shock and loss of life.)

Ordering Specifications

www.qlight.com

Please scan the QR code for more 

detailed product information.

Summary of Contents for QML series

Page 1: ...for Correct Use Failure to follow the proper instructions may cause damage to property the product and or malfunction of the product that would void the warranty 1 During wiring or maintenance please completely turn off the power of the product Failure to follow this may lead to an electric shock 2 Do not install the product in locations that subjects it to excessive dust or water other than the c...

Page 2: ...er QML 150 D QML 150 K QML 150 MF QML 250 D QML 250 K QML 250 MF QMHL 150 D QMHL 150 K QMHL 150 MF QMHL 250 D QMHL 250 K QMHL 250 MF Rated voltage DC24V DC24V DC24V DC24V Range for operation voltage DC21 5V 26 5V Current 0 530A 1 180A 0 510A 1 020A Power consumption 13W 29W 12W 25W Insulation resistance Min 100MΩ 500V DC mega ohm meter Withstanding voltage DC 500V AC 60Hz 1 minute Protection ratin...

Page 3: ...DC type cable specification External power line Dura Flex F VU 0 5sq x 2C 450mm Product can be wired regardless of polarity When wiring the product please ensure that the terminals are not exposed to coolant in order to prevent the bare wire from being contaminated Product can be wired regardless of polarity Please connect the 4 pins located in M12 connector cable to the M12 socket of the product ...

Page 4: ...K type bracket Loosen the bolt and adjust the tilt angle to the desired location before securing the bolt MF type bracket When tilt adjustment is needed loosen the bolt and adjust the tilt angle When swivel angle adjustment is needed loosen the bolt and swivel angle to the desired location When angle adjustment is done please secure the bolt VIEW A VIEW A QML 150 250 D QML 150 250 MF QML 150 250 K...

Page 5: ...Adjustment Parts Definition Please refer to page 4 in regards to bracket adjustment M12 Connector Type Model Customization M12 connector type product with a cable entry is available upon request Applied models QML 150 D QML 150 K QML 250 D QML 250 K QMHL 150 D QMHL 150 K QMHL 250 D QMHL 250 K VIEW A VIEW A QMHL 150 250 D QMHL 150 250 MF QMHL 150 250 K K type bracket MF type Bracket ...

Page 6: ...her and spring washer Installation Machine holes on the mounting surface referring to the diagram below Mounting Hole Specifications 140 240 90 100 45 45 30 15 4 Ø4 5 HOLES 4 Ø4 5 HOLES 4 Ø6 3 HOLES 3 Ø6 3HOLES QML QMHL 150 D QML QMHL 150 250 K QML QMHL 250 D QML QMHL 150 250 MF Installation Environment and Protection Rating This product is designed for use with protection rating of IP67 IP69K If ...

Page 7: ...ification Qlight products are designed to meet strict quality and technical standards Thus the Qlight brand is widely recognized for its high quality and technical innovations from leading institutions around the world ...

Page 8: ... Factory Shanghai Sales Office 19 Nanda Road Baoshan Area Shanghai China Tel 86 21 6651 7100 Fax 86 21 6315 3929 Product Operation Inquiry Customer Support 82 55 328 4082 You can expect prompt service if you have exact information such as model name symptom telephone number and address ALL PRODUCT PRODUCT SPECIFICATIONS AND DATAARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY FUNCTION O...

Reviews: