1
123
50
25
65
115
HORN
118
113
SMP35/ SMP50
Model
number
Voltage
Current
Volume
Input type/
No. of channel
Certificate Weight
SMP35
DC12-24V
MAX.0.800A • Warning sound :
Max. 115dB
• MP3 : Max. 113dB
Bit input : 5Ch
Binary input : 30Ch
0.76kg
1.03kg
AC110V-220V MAX.0.290A
SMP50
DC12V
1.800A
• Warning sound :
Max. 123dB
• MP3 : Max. 118dB
Bit input : 5Ch
Binary input : 30Ch
0.95kg
DC24V
MAX.1.000A
AC110V-220V MAX.0.600A
1.23kg
SMP50
-
110/220
-
LC
[Model number]
[Voltage]
[Sound selection]
|
|
|
• SMP35
• 12/24-DC12V-24V
• 110/220- AC110V-220V
• (Blank)-Built-in switch
• LC-External contact
• SMP50
• 12-DC12V
• 24-DC24V
• 110/220- AC110V-220V
Self-Standing Multifunctional Electric Sounder
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Precautions for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specification.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Failure to follow any of the instructions above may cause malfunction or damage to the product, fire, and electric shock.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the
product that would void the warranty.
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a fire to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point. (Failure to
follow these instructions may lead to fire, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to fire, electric shock, or product damage.)
5. When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device. (Failure to
follow this may cause damage to property, fire, electric shock and loss of life.)
Ordering Specifications
Product Specifications
• Protection rating :
IP65
• Ambient operating temperature :
-25°C to +50°C
※
CE Compliant : AC110V/ 220V
Please scan the QR code for more
detailed product information.
www.qlight.com
Summary of Contents for SMP50
Page 10: ...MEMO...
Page 11: ...MEMO...