background image

QM-Products 2016 v1.0 

 

                                                                   

 

 

 

 

 

 
 
 

  
 

SPM-2011 

 

2 x HDMI/AV to  1 x DVB-T/C  

 

 

        Operation Manual 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SPM-2011

Page 1: ...QM Products 2016 v1 0 1 SPM 2011 2 x HDMI AV to 1 x DVB T C Operation Manual ...

Page 2: ...carefully disconnect all plugs by taking off the plug and strictly forbitten to pull the cord in order to disconnect the unit Make sure the unit s power switch is turned off before removing the cord from an outlet Disconnect the mains cord when the unit is not in use for long periods of time or during storms Do not connect the unit to a multiple outlet to avoid plug overheating Disassembling This ...

Page 3: ...a long period of time make sure that the mains cord is disconnected Connectivity Before connecting the unit to other electronic devices always switch off and unplug all devices Maintenance Do not spill liquids on the unit Do not use any diluents or volatile liquid to clean the unit Instead use a soft slightly damp cloth and allow the unit to dry completely before using again Handling Do not poke y...

Page 4: ...DVD player to a CATV installation using the DVB T C signals 3 2 FEATURES 2 x independent HDMI AV inputs 1 x RF output DVB T C software selectable Full NIT Configuration Low power consumption MER value 40dB Very clean RF spectrum PCR re stamping Very friendly user interface Wall mountable Compact size 5 year warranty 3 2 1 Auto reset functions and watchdog During the normal operation of the SPM 201...

Page 5: ...QM Products 2016 v1 0 5 SPM 2011 1 Reset button 2 Status LED 3 IP LAN control 4 RF output 5 RF input 6 HDMI AV inputs ...

Page 6: ...g an Internet browser eg Internet Explorer Firefox or Chrome and type the following static IP 192 168 1 200 The default username and password are the following Username admin Password 12345 4 2 Embedded Webserver Status 4 2 1 General page Figure No 1 Every time that the user is connected to the device the General page Figure No 1 is loaded providing a current general status information of the devi...

Page 7: ...io PID and LCN number Output Modulator In these fields the user is able to see the status of all the RF output of the device such as modulator state RF output frequencies and modulation settings System This section provides general information of the device like internal status of all device s modules CPU temperature and fan state as well as error codes for troubleshooting purposes Setup 4 2 2 Inp...

Page 8: ...eferred service name 3 Service ID Insert the service ID number 4 Video Bitrate Set the video bitrate 2000 19000 Kbps 5 Audio Bitrate Set the audio bitrate 64 96 128 192 256 320 Kbps 6 Audio encoding Set the audio encoding AAC AC3 Mpeg2 7 HDCP Enable disable the HDCP function 8 LCN Set the LCN number 9 PMT PID Set the PMT PID 10 Video PID Set the Video PID 11 Audio PID Set the Audio PID Once all se...

Page 9: ...n Code Rate The coder rate Guard Interval The guard interval Channel Bandwidth The channel bandwidth Modulation The modulation type Enable Disable Enable or disable the modulator Output level Adjust the output level from 70 90dΒμV The status section provides a general idea to the user of the current payload according to the selected programs comparing to the max output payload It is recommended th...

Page 10: ...65535 Original Net ID Which is the Org Net ID No of the specific multiplex 1 65535 Network Name Which is the network name of the specific multiplex NIT User can choose the following options Off Basic Auto Custom LCN provider Choose the appropriate LCN provider EACEM ITC Nordig APN 4 2 4 NIT page In NIT page Figure No 5 the user is able to create a full customize NIT table Figure No 5 ...

Page 11: ...ure No 6 DHCP Enable or disable DHCP IP address Set a static IP address for controlling the device Subnet mask Set the specific Subnet mask Gateway Set the gateway s IP address Primary DNS Set the IP address of the primary DNS Secondary DNS Set the IP address of the secondary DNS Port Assign the control port MAC address Depicts the MAC address of the LAN control ...

Page 12: ...ation page In Administration section the user is able to change the default password of the webserver Figure No 7 4 2 7 System restart page Figure No 8 In System restart section Figure No 8 the user is able to apply a full reset to the device ...

Page 13: ...e user is able to apply a factory default reset either as DVB T or DVB C 4 2 9 Import Export Config page In Import Export Config section Figure No 10 the user is able to do the following Figure No 10 1 Export Save all the configuration is a specific file 2 Import Upload a previously save configuration file ...

Page 14: ...update Figure No 11 section the user is able to upload a new firmware update using the appropriate file Figure No 11 4 2 11 Info page Figure No 18 In Info Figure No 18 section the user is able to see the serial No of the device as well as the firmware and MAC address ...

Page 15: ...264 encoder Standard MPEG 4 AVC H 264 Bit Rate 1 19 Mbps adjustable Configurable Parameters Service Name Service ID LCN processing Yes Output Specifications DVB T Bandwidth 5 6 7 8MHz Mode 2K 8K Constellation QPSK 16QAM 64QAM Guard Interval 1 4 2 3 3 4 5 6 7 8 Code Rate 1 2 2 3 3 4 5 6 7 8 DVB C Bandwidth 5 6 7 8MHz Mode 2K 8K Constellation 16QAM 32QAM 64QAM 128QAM 256QAM Symbol Rate 1 7 2Ms s RF ...

Page 16: ...T Off Basic Auto Custom PCR re stamping LCN support Yes Programming Interface Ethernet webserver Yes embedded webserver Speed 10 100 Mbps Connector RJ45 Compatible browsers IE Edge Firefox Chrome General Power Supply 12 VDC 50 60Hz Power supply consumption 1 2A Operating Temperature 0 ºC to 40 ºC Storage Temperature 10 ºC to 70 ºC Humidity Up to 90 ...

Page 17: ... malfunctions caused by other equipment WARNING Our limited warranty is considered void if a product is returned with removed damaged or tampered labels or any alterations including removal of any component or external cover carried out by unauthorized personnel OUT OF WARRANTY SERVICING We repair and service units of our production even once the warranty has expired if this is economically the be...

Page 18: ... 3 4 7 465 8 294 8 782 9 048 5 6 8 294 9 216 9 758 10 053 7 8 8 709 9 676 10 246 10 556 16 QAM 1 2 9 953 11 059 11 709 12 064 2 3 13 271 14 745 15 612 16 086 3 4 14 929 16 588 17 564 18 096 5 6 16 588 18 431 19 516 20 107 7 8 17 418 19 353 20 491 21 112 64 QAM 1 2 14 929 16 588 17 564 18 096 2 3 19 906 22 118 23 419 24 128 3 4 22 394 24 882 26 346 27 144 5 6 24 882 27 647 29 273 30 160 7 8 26 126 ...

Page 19: ...4 6 532 7 257 7 684 7 917 5 6 7 257 8 064 8 538 8 797 7 8 7 620 8 467 8 965 9 237 16 QAM 1 2 8 709 9 676 10 246 10 556 2 3 11 612 12 902 13 661 14 075 3 4 13 063 14 515 15 369 15 834 5 6 14 515 16 127 17 076 17 594 7 8 15 240 16 934 17 930 18 473 64 QAM 1 2 13 063 14 515 15 369 15 834 2 3 17 418 19 353 20 491 21 112 3 4 19 595 21 772 23 053 23 751 5 6 21 772 24 191 25 614 26 390 7 8 22 861 25 401 ...

Page 20: ... 4 5 599 6 221 6 587 6 786 5 6 6 221 6 912 7 318 7 540 7 8 6 532 7 257 7 684 7 917 16 QAM 1 2 7 465 8 294 8 782 9 048 2 3 9 953 11 059 11 709 12 064 3 4 11 197 12 441 13 173 13 572 5 6 12 441 13 824 14 637 15 080 7 8 13 063 14 515 15 369 15 834 64 QAM 1 2 11 197 12 441 13 193 13 572 2 3 14 929 16 588 17 564 18 096 3 4 16 796 18 662 19 760 20 358 5 6 18 662 20 735 21 995 22 620 7 8 19 595 21 772 23...