0
Q-Motion Zigbee
Programming Guide
Integrating into Control 4 Automation System
Whenever blinds are integrated into a Control4 automation system, there is no need
to perform any programming or limit setting. Essentially the blinds will be installed and
left for the automation integrator to commission and set the limits.
Please do not try to manually operate the Roller Blind prior to Control4 integration, as
the motor may exit its ‘pairing mode’. The
Roller Blind will not function correctly and
continue to jog for several minutes, indicting it has not been setup.
If blinds are used as a standalone product (no Control4 automation system), please
continue with the steps below.
Setting up Q-Motion Zigbee without a Control 4 Automation
Systems
NOTE: Range Extender: Green LED will flash rapidly for 1 second when a device
(Blind/Remote) joins the network
Create a Network (Range Extender)
•
Power the RANGE EXTENDER using the provided power supply (Should be
centrally located to blinds)
•
PRESS and HOLD the NETWORK button until the GREEN LED illuminates (Green
LED illumination indicates the network is active)
Add Remote to Network
•
PRESS and HOLD the NETWORK button until the GREEN LED illuminates (Green
LED illumination indicates the network is active)
•
Pull battery tab from Remote
•
Use a paper clip to PRESS the PROGRAM button on back of the remote (The
channel LEDs will scroll back and forth when in program mode)
•
PRESS any button on the remote to join network (Green LED will flash when
remote joins the network)