R
www.quadrafire.com
7037-141B
March 28, 2012
QUADRA-FIRE 2100 & 4300 MILLENIUM ACC WOOD BURNER INSTALLATION INSTRUCTIONS
INSTALLATIONS TO COMPLY WITH AS/NZS2918:2001
AND WILL REQUIRE A BUILDING CONSENT
IMPORTANT: Read all instructions carefully before starting installation. Failure to follow these
instructions may result in a fire hazard and will void the warranty.
• Fig. 3,4,5 and Table 1 & 2 relate to installations with tested flue systems; as per
AS/NZS 2918:2001 -
Appendix F
, with a ceiling angle between 0° - 30° inclusive.
•
For installations with a ceiling angle greater than 30°, refer to Fig. 6 & 7 and
AS/NZS 2918:2001 4.6.3(b)
• Ceiling Plate may vary in size depending on ceiling angle. Please specify ceiling pitch prior to ordering the
ceiling plate.
• Quadra-Fire 2100 & 4300 Millenium ACC wood burner’s are tested and approved to the N.Z. National
Environmental Standards;
21M-ACC-NZ - 2100 Millenium ACC Softwood Certified
Particulate Emissions = 0.6 g/kg Space Heating Efficiency = 72%
21M-ACC-AU - 2100 Millenium ACC Hardwood Certified
Particulate Emissions = 2.0 g/kg Space Heating Efficiency = 81%
43M-ACC-NZ - 4300 Millenium ACC
Softwood Particulate Emissions = 0.4 g/kg Space Heating Efficiency = 71%
Hardwood Particulate Emissions = 2.5g/kg Space Heating Efficiency = 78%
Model:
21M-ACC-NZ
21M-ACC-AU
43M-ACC-NZ