CAUTION

• 

Important  operating 

and  maintenance  in

-

structions included.

•  Leave this manual with 

party  responsible  for 

use and operation.

•  Read,  understand  and 

follow these instructions 

for safe installation and 

operation.

DO NOT

DISCARD

 WARNING

If the information in these instruc-

tions is not followed exactly, a fire 

may result causing property dam-

age, personal injury, or death.

 

•  Do not store or use gasoline or other flam

-

mable vapors and liquids in the vicinity of 

this or any other appliance.

•  Do not overfire - If heater or chimney con

-

nector glows, you are overfiring. Overfiring 

will void your warranty.

•  Comply with all minimum clearances to 

combustibles as specified.  Failure to 

comply may cause house fire.

Fire Risk.

WARNING

For use with solid wood fuel only.

Other fuels may overfire and generate 

poisonous gases (i.e. carbon monoxide).

Installation and service of this appliance should 

be performed by qualified personnel.  Hearth & 

Home Technologies recommends NFI certified 

professionals, or technicians supervised by an 

NFI certified professional.

WARNING

Hot glass will cause burns.

•  Do not touch glass until it is cooled

•  NEVER allow children to touch glass

•  Keep children away

•  CAREFULLY SUPERVISE children in same room 

as fireplace.

•  Alert  children  and  adults  to  hazards  of  high 

temperatures.

High temperatures may ignite clothing or other 

flammable materials.

•  Keep  clothing,  furniture,  draperies  and  other 

flammable materials away.

HOT SURFACES!

Glass and other surfaces are 

hot during operation AND 

cool down.

To obtain a French translation of this manual, please 

contact your dealer or visit www.quadrafire.com

Pour obtenir une traduction française de ce manuel, 

s’il vous plaît contacter votre revendeur ou visitez 

www.quadrafire.com

NOTE

4300 WOOD STOVE SERIES

Automatic Combustion Control (ACC)

Owner’s Manual

Installation and Operation

Models: 

43M-ACC-MBK

43ST-ACC

Millennium Model

Step Top Uni-Body Model

(Pedestal Model Shown)

O-T  L

Tested and 

Listed by

Portland

Oregon USA

OMNI-Test Laboratories, Inc.

C

US

Summary of Contents for 43M-ACC-MBK

Page 1: ...f this appliance should be performed by qualified personnel Hearth Home Technologies recommends NFI certified professionals or technicians supervised by an NFI certified professional WARNING Hot glass will cause burns Do not touch glass until it is cooled NEVER allow children to touch glass Keep children away CAREFULLY SUPERVISE children in same room as fireplace Alert children and adults to hazar...

Page 2: ...perate only with the fuel loading door closed Open only to add fuel to the fire CAUTION U S ENVIRONMENTAL PROTECTION AGENCY Certified to comply with July 1990 particulate emission standards 2010 2011 2012 Jan Feb Mar Apr May June July Aug Sept Oct Nov Dec PREVENT HOUSE FIRES FLOOR PROTECTION Floor protector must be a 3 8 inch 10mm minimum thickness non combustible material or equivalent extending ...

Page 3: ...on 8 Operating Instructions A Over Firing Your Appliance 25 B Wood Selection Storage 25 C Burning Process 25 26 D Automatic Combustion Control ACC 26 E Air Controls 26 27 F Burn Rates Operating Efficiency 27 G Building A Fire 28 H Correct Baffle Blanket Placement 29 I Blower Operating Instructions 29 J Opacity Smoke 29 K Frequently Asked Questions 30 Section 9 Maintaining Servicing Appliance A Qui...

Page 4: ... cubic feet Max Wood Length 20 inches Fuel Cord Wood Shipping Weight 355 lbs Model 4300 Millennium Step Top ACC Uni Body Laboratory OMNI Test Laboratories Inc Report No Date 061 S 67 6 Type Listed Room Heater Solid Fuel Type Standard UL1482 and ULC S627 00 and UM 84 HUD Mobile Home Approved NOTE Hearth Home Technologies manufacturer of this appliance reserves the right to alter its products their ...

Page 5: ...ting appliance and close to the sleeping areas Follow the smoke detector manufacturer s placement and installation instructions and be sure to maintain regularly 2 A conveniently located Class A fire extinguisher to contend with small fires resulting from burning embers 3 A practiced evacuation plan consisting of at least two escape routes 4 A plan to deal with a chimney fire as follows In the eve...

Page 6: ...e include Exhaust fans kitchen bath etc Range hoods Combustion air requirements for furnaces water heaters and other combustion appliances Clothes dryers Location of return air vents to furnace or air condi tioning Imbalances of HVAC air handling system Upper level air leaks Recessed lighting Attic hatch opening Duct leaks To minimize the affects of negative air pressure the following must be cons...

Page 7: ...ce after one hour of operation at each burn setting NOTE These are guidelines only and may vary somewhat for individual installations F Tools And Supplies Needed Before beginning the installation be sure that the following tools and building supplies are available Reciprocating saw Pliers Hammer Phillips Head Screwdriver Flat Blade Screwdriver Plumb Line Level Tape Measure Framing Material Hi Temp...

Page 8: ... Termination Cap Outside Air Rear Vent Spark Arrestor Cap Floor Protector Chimney Connector Ceiling Support Listed Chimney Listed Termination Cap Storm Collar Flashing Figure 8 3 Interior Prefabricated Chimney Figure 8 2 Exterior Prefabricated Chimney Figure 8 1 Masonry Chimney H Typical Stove Systems Stove system with masonry chimney consists of Stove Chimney Connector stove pipe Thimble Masonry ...

Page 9: ...6mm 11 1 2 in 292mm 20 3 4 in 527mm C L 3 7 16 87mm 4 1 2 in 108mm Outside Air Connection C L A Appliance Dimensions Figure 9 1 Front View Figure 9 2 Side View NOTE Flue Collar size is 6 inch 152mm diameter ID Millennium Model 14 15 16 in 373mm 26 in 660mm 9 3 4 in 247mm 13 in 330mm 31 in 762mm 15 1 16 in 383mm 10 15 16 in 271mm 19 1 16 in 475mm C L ...

Page 10: ... 25 1 16 in 636mm 32 7 8 in 835mm 15 1 16 in 383mm 19 1 16 in 484mm 10 15 16 in 278mm 14 15 16 in 379mm 3 11 16 in 94mm 23 1 8 in 587mm 9 5 8 in 244mm 6 11 16 in 170mm 3 1 2 in 89mm C L 34 3 4 in 883mm 26 in 660mm 13 in 330mm 9 3 4 in 248mm C L 18 in 457mm 28 11 16 in 729mm 26 5 16 in 668mm 15 5 8 in 397mm 11 1 2 in 292mm 16 in 406mm 20 3 4 in 527mm 4 1 2 in 108mm Outside Air Connection C L ...

Page 11: ...3 75 95 22 559 11 75 298 2 51 12 305 49 5 1283 5 127 INSTALLATION 90 Elbow Off Top of Stove Through Backwall DOUBLE WALL PIPE Flat Top Model 8 5 216 6 152 24 5 622 15 381 10 254 17 5 445 53 5 1359 N A Step Top Model 7 5 191 4 102 19 229 9 229 2 51 12 305 49 5 1283 N A INSTALLATION ALCOVE Six inch 6 152mm diameter listed Double Wall air insulated connector pipe with UL103 HT listed factory built Cl...

Page 12: ... the opening in the face of the appliance See exception 16 from glass 8 in Fuel loading door 31 5 8 in minimum 41 3 8 in minimum 3 1 5 8 i n 2 7 3 8 i n 37 in 4 0 1 5 1 6 i n 3 1 1 6 i n 135 o p t i o n a l c o v e r a g e 51 1 16 in Must extend 2 in 51mm beyond each side of pipe shaded area 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1334mm 52 1 2 in minimum 1066mm 42 in minimum In Canada simila...

Page 13: ...design preference Hearth Home Technologies reserves the right to alter its products 16 in from glass 8 in Fuel loading door 31 5 8 in minimum 41 3 8 in minimum 203mm 8 in 203mm 8 in 203mm 8 in 457mm 18 in 1334mm 52 1 2 in minimum 1066mm 42 in minimum USA required Canada recommended Figure 13 3 Figure 13 1 Figure 13 2 Figure 13 4 Step Top Uni Body Model 48 5 16 in 3 1 5 8 i n 4 0 1 5 1 6 i n 2 7 5 ...

Page 14: ...ve tightly sealed doors and windows an outside air source is needed An optional Outside Air Kit is available Flex Line Wire Tie Wire Tie Flex Adapter Termination Cap For Floor Installa tions Remove Circular Knock Out in Base of Pedestal WARNING Do not draw outside combustion air from Wall floor or ceiling cavity Enclosed space such as an attic or garage Close proximity to exhaust vents or chimneys...

Page 15: ...f appliance 4 Place the bracket containing the snap disc and magnet under the bottom left rear corner as shown in Figure 15 1 See page 30 for detailed operating instructions for the blower and snap disc Figure 15 1 Shock Risk Do NOT remove grounding prong from plug Plug directly into properly grounded 3 prong receptacle Route cord away from appliance Do NOT route cord under or in front of applianc...

Page 16: ... steel black or 26 gauge blued steel or an approved air insulated double wall venting pipe Thimble A manufactured or site constructed device installed in combustible walls through which the chimney connector passes to the chimney It is intended to keep the walls from igniting Site constructed thimbles must meet NFPA 211 Standards Prefabricated must be suitable for use with selected chimney and mee...

Page 17: ... framing lumber to fit into wall opening Inside opening of frame should be no less than 14 inch x 14 inch 356mm x 356mm Figure 17 1 4 Attach the wall spacer to the chimney side of the frame 5 Nail the frame into the wall opening The spacer should be on the chimney side 6 Insert the section of the solid insulated chimney into the outer wall of the masonry chimney 7 Tightly secure the length of the ...

Page 18: ...ectors must conform to each other to ensure a proper fit and seal Flue Gas Direction Crimped End Toward Stove Secure pipe sections with a minimum of 3 screws Figure 18 2 Chimney Connector Stove Pipe Improper installation adjustment alteration service or maintenance can cause injury or property damage Refer to the owner s information manual provided with this appli ance For assistance or additional...

Page 19: ...e roof within 10 feet 305cm Must be located away from trees or other struc tures These are safety requirements and are not meant to assure proper flue draft Figure 19 1 E 2 10 3 Rule Figure 19 2 NOTE Chimney performance may vary Trees buildings roof lines and wind conditions affect performance Chimney height may need adjustment if smoking or overdraft occurs 3 ft 91cm Minimum Less than 10 ft 305cm...

Page 20: ...r manufacturer s instructions when installing the flue system for use in a mobile home 7 Maintain clearance to combustibles 8 Floor protection requirements must be followed precisely 9 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure NOTE Offsets from the vertical not exceeding 45 are allowed per Sect...

Page 21: ...back on a protective pad or pallet 3 Remove the 2 nuts and 2 bolts holding the channel in place and set the channel aside Discard the 2 nuts Install the gasket over the 8 protruding screws The glossy side of the gasket needs to go against the firebox bottom It is important the gasket is not put on upside down as it could compromise its sealing capa bilities Figure 21 2 4 Install ash door assembly ...

Page 22: ...5 Slip wooden decorative strips onto pedestal edges Finishing the ARS Installation 1 Re install the ARS channel that was removed in Step 3 on page one and secure with 2 bolts previously removed Set the cover into the ARS channel Replace the 2 front cut bricks Figure 22 2 2 Install the ash drawer 3 Check to make sure baffle boards and ceramic blanket are in their proper locations see page 29 NOTE I...

Page 23: ...m screws of the mounting brackets to the bottom of the stove with 1 4 20 Phillips head screws These screws are located in the component pack Leave the bottom 2 screws loose so you can slide the ash pan assembly bottom slots over the screw heads This al lows the weight of the ash pan to rest on the screws while you are attaching the top 2 screws Once the ash pan is attached tighten all screws Figur...

Page 24: ... to slow the blower and counterclockwise to increase the speed The blower speed control for this unit is adjusted at the factory and normally does not require further adjustment D Adjusting The Blower Speed Control C Door Handle Assembly 1 Install washer on door handle shaft 2 Slide door handle through door 3 Install second washer s as shown 4 Install key in groove 5 Align groove in latch cam with...

Page 25: ...nd establishing the flue draft not evaporating the moisture out of wet unseasoned wood resulting in wasted heat Do not over fire Over firing may ignite creosote or will damage the stove and chimney To prevent over firing your stove DO NOT Use flammable liquids Overload with wood Burn trash or large amounts of scrap lumber Permit too much air to the fire WARNING Fire Risk Symptoms of over firing ma...

Page 26: ...This function is performed by sliding the con trol all the way back until it stops at the HI indicator on the label and then pulling forward to the front of the stove until it stops This activates the ACC system and opens the front air channel and allows air to enter the front of the stove for approximately 25 minutes The front air channel gradually shuts down until it is completely closed at the ...

Page 27: ... This air is regulated by the Burn RateAir Control There are four settings High Medium High Medium Low and Low When the control is raised all the way up it is on the High setting and when pushed all the down it is on the Low setting Figure 27 1 NOTE These are approximate settings and will vary with type of wood or chimney draft Due to altitude and other environmental circumstances this operational...

Page 28: ... 102mm in diameter Be careful not to smother the fire Stack the pieces of wood carefully near enough to keep each other hot but far enough away from each other to allow adequate air flow between them 7 Set the Burn Rate Air Control and activate the timer system ACC 8 When ready to reload It is best to fully open both the Burn Rate Air and Start up Air Controls before reload ing This livens up the ...

Page 29: ...t is not covered by warranty Operate the wood burning appliance with the baffle in the correct position only Not doing so could result in Reduced efficiency Overheating the chimney Overheating the rear of the firebox Poor performance WARNING Fire Risk Ensure correct baffle placement and replace baffle components if damaged or missing INCORRECT POSITIONS CORRECT POSITION Ceramic Blanket and Baffle ...

Page 30: ...re is a manual over ride switch to deactivate the snap disc if necessary See page 15 I Blower Operating Instructions Fire Risk Keep combustible materials gasoline and other flammable vapors and liquids clear of appliance WARNING DO NOT STORE FLAMMABLE MATERIALS IN THE APPLIANCE S VICINITY Do NOT use gasoline lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a f...

Page 31: ...revent pipe blockage poor draft and chimney fires Always burn dry wood to help prevent cap blockage and creosote build up Keeping the door and glass gasket in good shape will maintain good burn times on a low burn setting Check the glass frame for loose screws to prevent air leakage Check the door latch for proper adjustment This is very important especially after the door rope has formed to the s...

Page 32: ...nded that before each heating season the entire system be professionally inspected cleaned and repaired if necessary a The stove and ashes must be completely cooled down before using the Ash Removal System Reach down and locate the ash removal door handle under the left side of the stove in the center Squeeze the handle and push all the way back Amagnet will hold the handle in place which in turn ...

Page 33: ...rcially available oven cleaner After using an oven cleaner it is advisable to remove any residue with a glass cleaner or soap and water Oven cleaner left on during the next firing can permanently stain the glass and damage the finish on plated metal surfaces Aportion of the combustion air entering the firebox is deflected down over the inside of the door glass This air flow washes the glass helpin...

Page 34: ...each retainer just a few turns until each is secured Check again for centering of glass in door frame Continue to tighten each retainer alternately a few turns at a time until the glass is secure DO NOT OVERTIGHTEN 9 Replace the door on the appliance Quadra Fire stoves are equipped with ceramic super heat resistant glass which can only be broken by impact or misuse Do not slam stove door or impact...

Page 35: ...Slide top of brick under clips on side of firebox and push the bottom of the brick until it is flush with the side of the appliance C Firebrick Replacement Use Part 832 0550 when ordering individual brick Provide brick dimension or copy this page mark the desired brick and take it to your authorized dealer Figure 35 2 4300 Step Top Brick Assembly NOTE The Ash Removal System is only available for t...

Page 36: ...Place on top of baffle board open up and flatten and smooth out the blanket Re check the baffle board for correct positioning Figure 36 2 Figure 36 1 Baffle Figure 36 2 Ceramic Blanket E Snap Disc Replacement Magnet Spade Connectors Snap Disc Figure 36 3 1 Locate the snap disc bracket assembly at the bottom left rear corner of the stove Figure 36 3 2 A magnet holds the bracket to the stove Pull th...

Page 37: ...the tube channel assembly into side of firebox and insert each tube into the corresponding hole in the tube channel rack starting with the back hole first 3 Make sure tube channel assembly is flush against the side of the stove and secure with channel nuts 4 Re install channel cover and side shield Channel Access Cover Channel Nuts 2 Side Panel Tube Channel Assembly Channel Cover Screws 4 Tube Cha...

Page 38: ...he appliance towards the wind Wood condition is too wet too large Use dry seasoned wood refer to wood fuel sec tion Bed of coals not established before adding wood Start with paper kindling to establish bed of coals refer to starting fire section Flue blockage such as birds nests or leaves in termination cap Have chimney inspected for creosote and cleaned by a certified chimney sweep Down draft or...

Page 39: ...ed Drawing Millennium Figure 39 1 Service Parts 12 11 R Wood Stove 4300 ACC Millenium Part number list on following page 43M ACC GT Oct 2006 Jan 2007 43M ACC NT Oct 2006 Jan 2007 1 2 3 4 5 7 6 8 9 10 11 12 13 14 15 Beginning Manufacturing Date Oct 2006 Ending Manufacturing Date Active 43M ACC MBK ...

Page 40: ...bel Burn Rate Air Control 7033 160 12 Label Start Up Air Control Acc 7033 166 13 Panel Assembly Right Side 7037 006 14 Tube Channel Access Cover Top SRV7033 237 15 1 Burn Rate Control Assembly 7037 004 Y 15 2 Spring Handle 1 4 Gold Pre SN 0070030424 832 0630 Y Spring Handle 1 4 Nickel 250 8340 Y Spring Handle 1 4 Black Post SN 0070030424 SRV7000 614 Y 15 3 Door Gasket Front Rear Air Timer Doors 70...

Page 41: ... Brick 6 x 4 5 Qty 4 Reg 16 3 Brick 9 x 4 5 with angle Qty 1 Reg 16 4 Brick 9 x 3 with angle Qty 1 Reg 16 5 Brick small Qty 2 Reg Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 17 Pedestal Assembly 17 1 Pedestal Riser 7033 207 17 2 Pedestal Base 7033 163 17 3 Strip Oak Trim Qty 2 Req 832 0560 Additional service part numbers appear on following page 4300 ACC Millenium 16 Brick Set Assembly 16 1 16...

Page 42: ...Y Spring Handle 1 2 Black Post SN 0070030424 SRV7000 613 Y 18 5 Trim Ring For Door Trim door assembly only Gold Trim 430 2682 Nickel Trim 430 5340 18 6 Door Glass Assembly 15 1 2 W x 13 3 8 H 7000 012 Y 18 7 Glass Frame Set Qty 4 Pc 832 0350 18 8 Cam Latch 430 1141 18 9 Key Cam Latch 430 1151 18 10 Nut Locking Door Handle Pkg of 24 226 0100 24 Y Gasket Glass Tape Field cut to Size Qty 5 Ft Req 832...

Page 43: ... 168 4 Y Logo Quadra Fire Gold 200 3180 Nickel 200 3240 Paint Touch Up Black 812 0910 Outside Air Kit Floor Rear OAK ACC Outside Air Collar Assembly 7033 039 Outside Air Shield 33271 Y FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1 Pkg of 10 25221A 10 Y Button Head 1 4 20 X 5 Pkg of 20 32328 20 Y Nut Keps Lock 10 32 Pkg of 40 226 0050 40 Y Nut K...

Page 44: ...ve Series ACC C Exploded Drawing Step Top Figure 44 1 Service Parts 12 11 R Step Top Model Wood Stove 43ST ACC Beginning Manufacturing Date Feb 2007 Ending Manufacturing Date Active Part number list on following page 1 2 3 4 5 6 7 8 9 10 11 12 13 15 14 ...

Page 45: ...ard 9 1 2 W x 15 3 4 H Qty 2 SRV7037 112 Y 9 Rear Channel Assembly 7033 002 Y 10 Label Burn Rate 7033 160 11 Panel Assembly Side Right 7037 010 12 Label Start Up Acc 7033 166 13 Tube Channel Top Access Cover SRV7033 237 14 Tube Channel Assembly Manifold Tubes SRV7033 023 Y 15 1 Burn Rate Control Assembly 7037 004 Y 15 2 Spring Handle 1 4 Gold 832 0630 Y Nickel 250 8340 Y 15 3 Door Gasket Front Rea...

Page 46: ... 4 25 Qty 2 Reg 16 5 Brick 9 x 3 with angle Qty 1 Reg 16 6 Brick small Qty 2 Reg Brick Uncut Pkg of 1 832 0550 Pkg of 6 832 3040 17 Ash Pan removal System 17 1 Door Assembly ARS Ash Pan Removal System SRV7033 015 Y 17 2 Gasket SRV7033 296 Y 17 3 Latch Handle Assembly SRV7033 047 Y 17 4 Magnet Round 7000 552 Y Additional service part numbers appear on following page 43ST ACC Beginning Manufacturing...

Page 47: ...d 831 1250 Nickel LEGS QANL 18 Leg Mount Kit SRV7037 132 Ash Pan Leg ARS Ash Pan Removal System 7033 050 Component Pack Leg Step Top Includes Gasket For Ash Removal Magnet Fasteners 7033 048 Pedestal PED 3143 18 Pedestal Assembly 7033 013 19 Ash Pan Assembly 7033 010 Ash Pan Door Handle 7033 274 Outside Air Cover Plate Assembly SRV7033 041 Y Component Pack Pedestal Leg Step Top Includes Gasket For...

Page 48: ...2 Nickel 430 5320 19 3 Door Handle Rod Only 430 1131 19 4 Spring Handle 1 2 Gold 832 0620 Y Nickel 250 8330 Y 19 5 Trim Ring For Door Trim door assembly only Gold Trim 430 2682 Nickel Trim 430 5340 19 6 Door Glass Assembly 15 1 2 W x 13 3 8 H 7000 012 Y 19 7 Glass Frame Set Qty 4 Pc 832 0350 19 8 Cam Latch 430 1141 19 9 Key Cam Latch 430 1151 19 10 Nut Locking Door Handle Pkg of 24 226 0100 24 Y G...

Page 49: ... 200 3240 Outside Air Collar Assembly 7033 039 Outside Air Kit Floor Rear OAK ACC Outside Air Shield 33271 Y Paint Touch Up 812 0910 Snap Disc Bracket Assembly 7033 036 Snap Disc 1 Convection Blower SRV230 0470 Y Upgrade Door Nickel Nickel Handles Hinge Pins Logo UK DRNL Wire Harness Blower 7033 262 FASTENERS Avk Rivnut Repair Kit 1 4 20 3 8 16 Rivnut Tools RIVNUT REPAIR Y Bolt Hex Head 1 4 20 X 1...

Page 50: ...Page 50 7037 135H December 16 2011 R 4300 Wood Stove Series ACC C Warranty Policy ...

Page 51: ...December 16 2011 7037 135H Page 51 4300 Wood Stove Series ACC R ...

Page 52: ...ership purchased from Dealer phone Notes We recommend that you record the following pertinent information for your 4300 WOOD STOVE ACC DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance in structions included Leave this manual with party responsible for use and operation Read understand and follow these instructions for safe installation and operation D O N O T D I S C A R D Th...

Reviews: