background image

Quanta

S100-L11D

1U Server

        User's Guide

Date Modified: March 13, 2014 2:38 pm Document Version: 1.0

Summary of Contents for S100-L11D

Page 1: ...Quanta S100 L11D 1U Server User s Guide Date Modified March 13 2014 2 38 pm Document Version 1 0 ...

Page 2: ...ns and the names of the folders menus programs and files Enter type face denotes keyboard keys WARNING Warning information appears before the text it references and should not be ignored as the content may prevent damage to the device CAUTION CAUTIONS APPEAR BEFORE THE TEXT IT REFERENCES SIMILAR TO NOTES AND WARNINGS CAUTIONS HOWEVER APPEAR IN CAPITAL LETTERS AND CONTAIN VITAL HEALTH AND SAFETY IN...

Page 3: ...nd com munication cables Turn off the server and disconnect the power cord telecommunications systems networks and modems attached to the server before opening it Otherwise personal injury or equipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD work station...

Page 4: ...g the wide sides can damage the contacts inside the jumper causing intermit tent problems with the function controlled by that jumper Take care to grip with but not squeeze the pliers or other tool used to remove a jumper or the pins on the board may bend or break ...

Page 5: ...claimer The information in this document is subject to change without notice The manufacturer makes no representations or warran ties with respect to the contents hereof and specifically dis claims any implied warranties of merchantability or fitness for any particular purpose Furthermore the manufacturer reserves the right to revise this publication and to make changes from time to time in the co...

Page 6: ...About the Server Chapter 1 ...

Page 7: ...M Storage Twelve 3 5 SATA fixed drives or eight 3 5 SAS 4 3 5 SATA see Hard Disk Drives on page 2 21 One 2 5 SSD fixed drive Fixed SKU only SATADOM support Network Four Intel Haswell i210 RJ45 GbE ports Intel 82599 10GbE SFP optional Power Sub system 400W fixed power supply system Fixed PSU SKU only 450W redundant power supply system Redundant PSU SKU only System Features Features SPECIFICATION DE...

Page 8: ...P port Management Port 1 Dedicated 10 100 BASE T RJ45 manage ment port Integrated Graphics BMC Aspeed AST2300 8MB DDR3 Video memory Features SPECIFICATION DESCRIPTION Rear I O 2 USB 3 0 ports 1 VGA port 1 RS232 serial port 4 1GbE RJ45 ports 1 10 100Base T RJ45 management port 1 10GbE SFP port optional Power Supply 1 400W high efficiency PSU 100 240VAC 50 60Hz for fixed PSU SKU only 1 or 2 450W hig...

Page 9: ...S 1 3 1 2 Package Contents 1 1U server chassis 1 Heat sink 4 Dummy DIMMs installed 1 Fixed Power Supply fixed PSU PSU only 1 or 2 Redundant Power Supply redundant PSU SKU only 1 Power cord Utility CD Technical Guide included Rail kit ...

Page 10: ...dundant PSU SKUs For further reference in this manual SKU1 is desig nated as the fixed PSU model while SKU2 is the redundant one System Overview SKU1 Fixed PSU System Overview SKU2 Redundant PSU 4 1 5 2 6 2 2 3 Component Overview NO ITEM DESCRIPTION 1 3 5 HDDs 12 3 5 hard disk drive HDD 2 HDD board Connect to HDDs 1 5 2 2 2 3 6 5 4 7 ...

Page 11: ...nt PSU SKU2 only Redundant Power Supply Unit PSU 450W high efficiency redundant PSU 100 240VAC 50 60Hz Note A redundant PSU is not supported in a fixed PSU SKU A fixed PSU is not supported in a redundant PSU SKU 6 2 5 HDD bay SKU1 only 1 2 5 HDD SSD Air Duct SKU2 only Redundant PSU SKU only 7 PDB SKU2 only power distribution board Provides power connectivity for PSU fan HDD MB 12V MB power and MB ...

Page 12: ...YSTEM FRONT VIEW 1 6 System Front View System Front View 1 0 2 3 4 5 7 8 9 10 11 6 2 1 1 System Front View NO FEATURE DESCRIPTION 1 Control Panel Control system and status display See Front Control Panel LED on page 1 11 ...

Page 13: ...n link Blinking LAN access 6 Status LED See LEDs on page 4 2 for more informa tion Note See event log for more information after the table Status LED activity 1 0 2 3 4 5 7 8 9 10 11 6 2 1 1 2 3 4 6 7 8 9 10 5 7 ID LED Blue ON selected unit ID OFF no ID requested 8 Power LED Blue ON S0 SYSTEM POWER ON OFF S4 S5 SYSTEM POWER OFF Blinking S1 Standby Sleep 9 ID Button Push button to light up off the ...

Page 14: ...Fixed Power Supply Unit PSU for fixed PSU SKU only Redundant PSU Redundant Power Supply Unit PSU for redun dant PSU SKU only Note A redundant PSU is not supported in a fixed PSU SKU A fixed PSU is not supported in a redundant PSU SKU 2 System Rear I O Mainboard MB I O features 3 Expansion Card 1 PCIe Gen3 x8 card System Rear View Continued NO FEATURE DESCRIPTION ...

Page 15: ...upply Unit SKU2 A system has one or two redundant power supply unit PSU and a single power distribution board PDB PSU PSU Power Supply Units by Model MODEL PSU AC INPUT S100 L11D 1 400W high efficiency PSU 100 240VAC 50 60Hz Or 1 or 2 450W high efficiency redundant PSU 100 240VAC 50 60Hz optional 110 220V Note A redundant PSU is not supported in a fixed PSU SKU A fixed PSU is not supported in a re...

Page 16: ... T RJ45 port 3 COM VGA Ports Connect a monitor or serial devices to this port 4 NIC5 10G BASE T SFP port 5 Dedicated Management LAN Port 6 USB port 2 USB ports 3 0 compliant Note The width of the USB drive needs to be lower than 17mm to avoid interfering with the use of the other port 1 2 6 3 4 5 Expansion Slot ITEM NAME DESCRIPTION 1 PCIe expan sion slot 1 PCIe Gen3 x8 Riser Card optional 1 ...

Page 17: ...IC3 and NIC4 do not function LAN LED 1 Blue LAN Link to NIC1 or NIC2 Blinking LAN Link to NIC1 or NIC2 active OFF NIC1 and NIC2 do not function Fault LED Amber Blinking Critical Error OFF System OK ID LED Blue Identify this system OFF No identification Power LED Blue S0 system power on OFF S5 system power off Blinking S1 Standby Sleep HDD LED Behavior HDD STATUS BLUE LED AMBER LED Slot Empty OFF O...

Page 18: ...ITION DESCRIPTION On Green Power on Off Power off Blinking Green AC present only 5VSB on PS off On Amber AC core unplugged AC power loss sec ond PSU in parallel with AC input power Blinking Amber PSU fault high temp high power high current slow fan On Amber Critical fault with shutdown failure OCP OVP fan fail and OTP RJ45 LED Description STATUS LINK LED ACTIVITY LED Unplug Off Off 1G Link with Ac...

Page 19: ...gement Port LED SFP LED Description STATUS LINK LED ACTIVITY LED Unplug Dark Dark 10G Link with Active Green blinking Blue Link Activity Management Port LED Behavior STATUS LINK LED ACTIVITY LED Unplug Off Off 100M Link Active Green on Green blinking 10M Link Active Off Green blinking PSU1 Link Activity ...

Page 20: ...Installation and Assembly Safety Instructions Chapter 2 ...

Page 21: ...d AC power cord if it is not the exact type required A product with more than one power supply will have a separate AC power cord for each supply The power button on the system does not turn off system AC power To remove AC power from the system you must unplug each AC power cord from the wall outlet or power supply The power cord s is considered the disconnect device to the main AC power The sock...

Page 22: ...ge ESD protection by wearing an antistatic wrist strap attached to chassis ground of the system any unpainted metal surface when handling components 6 Do not operate the system with the chassis covers removed After you have completed the six SAFETY steps above you can remove the system covers To do this 1 Unlock and remove the padlock from the back of the system if a padlock has been installed 2 R...

Page 23: ...heck that cables add in cards and other components are properly installed 3 Attach the covers to the chassis with the screws removed earlier and tighten them firmly 4 Insert and lock the padlock to the system to prevent unauthorized access inside the system 5 Connect all external cables and the AC power cord s to the system Danger of explosion if the battery is incorrectly replaced Replace only wi...

Page 24: ... surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect WARNING The server system is safety certified as rack mounted equipment for use in a server room or computer room using the customer ...

Page 25: ...Safety Information Chapter 3 ...

Page 26: ... specified in this guide Use of other products components will void the UL List ing and other regulatory approvals of the product and may result in noncompliance with product regulations in the region s in which the product is sold Safety Warnings and Cautions To avoid personal injury or property damage before you begin installing the product read observe and adhere to all of the fol lowing safety...

Page 27: ...ct AC power Please recycle battery The rail racks are designed to carry only the weight of the server system Do not use rail mounted equipment as a workspace Do not place additional load onto any rail mounted equipment Indicates two people are required to safely handle the system Restricted Access Location The server is intended for installation only in a Server Room or Computer Room where both th...

Page 28: ...surge suppressor and disconnect telecommunication lines to your modem during an electrical storm Provided with a properly grounded wall outlet Provided with sufficient space to access the power supply cord s because they serve as the product s main power disconnect Provided with either two independent AC power sources or two independent phases from a s single source Equipment Handling Practices Re...

Page 29: ... OF SHOCK USE CAUTION WHEN WORKING WITH POWER SUPPLIES THAT USE NEUTRAL POLE FUSING CAUTION THE POWER SUPPLY IN THIS PRODUCT CONTAINS NO USER SER VICEABLE PARTS DO NOT OPEN THE POWER SUPPLY HAZARDOUS VOLTAGE CURRENT AND ENERGY LEVELS ARE PRESENT INSIDE THE POWER SUPPLY RETURN TO MANUFACTURER FOR SERVICING CAUTION WHEN REPLACING A HOT PLUG POWER SUPPLY UNPLUG THE POWER CORD TO THE POWER SUPPLY BEIN...

Page 30: ...nnect the AC power by unplugging all AC power cords from the system or wall outlet Disconnect all cables and telecommunication lines that are connected to the system Retain all screws or other fasteners when removing access cover s Upon completion of accessing inside the product refasten access cover with original screws or fasteners Do not access the inside of the power supply There are no servic...

Page 31: ...ronment may be greater than room ambient There fore consideration should be given to installing the equipment in an environment compatible with the maximum ambient tem perature Tma specified by the manufacturer Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounti...

Page 32: ...ilable but not the board wrap per Do not slide board over any surface Other Hazards Battery Replacement CAUTION ESD CAN DAMAGE DRIVES BOARDS AND OTHER PARTS WE REC OMMEND THAT YOU PERFORM ALL PROCEDURES AT AN ESD WORK STATION IF ONE IS NOT AVAILABLE PROVIDE SOME ESD PROTECTION BY WEARING AN ANTISTATIC WRIST STRAP ATTACHED TO CHASSIS GROUND ANY UNPAINTED METAL SURFACE ON YOUR SERVER WHEN HANDLING P...

Page 33: ...EM PARTS TO INSTALL THE COVERS Check first to make sure you have not left loose tools or parts inside the system Check that cables add in cards and other components are properly installed Attach the covers to the chassis according to the product instructions CAUTION TO AVOID RISK OF RADIATION EXPOSURE AND OR PERSONAL INJURY Do not open the enclosure of any laser peripheral or device Laser peripher...

Page 34: ...Regulatory and Compliance Infor mation Chapter 4 ...

Page 35: ... does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and the receiver Connect the equipment to an outlet on a circuit other than the one to...

Page 36: ...aiwan The BSMI Certification Marking and EMC warning is located on the outside rear area of the product Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following regulated com ponents must be used and conditions adhered to Interchang ing or use of other component will void the UL listing and other product certifica...

Page 37: ... with the European Direc tive 2011 65 EU Compliance is based on declaration that mate rials banned in the RoHS Directive are either 1 below all applicable threshold limits or 2 an approved pending RoHS exemption applies RoHS implementation details are not fully defined and may change Threshold limits and banned substances are noted below Quantity limit of 0 1 by mass 1000 PPM for Lead Mercury Hexa...

Page 38: ... this device is sub ject to the following two conditions 1 This device may not cause harmful inter ference and 2 This device must accept any interfer ence received including interference that may cause undesired operation VCCI Marking Class A Japan BSMI Certifi cation Num ber Class A Warning Taiwan R43039 ICES Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numér...

Reviews: