background image

V1.0 (1220) Note: 

SeaTalk

™ 

is a registered trademark of Raymarine.

 

USING THE CONFIGURATION SOFTWARE (WINDOWS):

 

Ad

-

hock WiFi passwords can be changed for security and memorability.

 

 

WiFi can be changed from Ad

-

hoc (default) to  Station mode or Standby.

 

Station mode 

is configured by inputting your router/access point

s details into the Configuration 

software.  (once configured, the correct settings must be entered into your chart software.)

 

 

Filtering: using the black list function

 

If desired, selected NMEA sentences can be blocked  from chosen input/s, using the 

black list 

‘ 

field. Remove the 

‘$’ 

or 

‘!’ 

from the 5 digit NMEA talker and sentence identifier and insert sepa-

rated by commas. For example to block 

‘!

AIVDM

’ 

and 

‘$

GPAAM

’ 

enter 

AIVDM,GPAAM

’ .

 

Up to 8 sentences types can be filtered from each input port.  If blacklisting SeaTalk

1

 

data, block 

the corresponding NMEA message (see the manual for a full list of converted messages).

 

 

Routing your data.

 

As a default, all inputs

’ 

data (excluding any filtered data) is routed to all outputs . Data can be 

routed to limit the data flow to certain output/s by un

-

ticking the corresponding boxes in the 

Configuration software. This is critical if outputting to  NMEA 0183 to avoid overflow as NMEA 
0183 is considerably slower than NMEA 2000.

 

 

Monitor the  data stream Via USB

 

Use the 

Display

’ 

tab on the Configuration tool to monitor all input data including the data 

 

received through NMEA 2000 backbone. (both PCDIN and NMEA 0183 format)

 

 

NMEA Default Baud rates 

can be adjusted as required. Default Baud rates settings are:

 

• 

NMEA IN 1 and 2: 4800bps

 

• 

NMEA IN 3: 38400bps 

 

• 

NMEA OUT: 4800bps

 

Disclaimer: 

This product is designed to aid navigation and should be used to augment normal navigational procedures 

and practices. It is the user

s responsibility to use this product prudently. Neither Quark

-

elec, nor their distributors or 

dealers accept responsibility or liability either to the product user or their estate for any accident, loss, injury or 
damage whatsoever arising out of the use or of liability to use this product.

 

QK

-

A034

-

B

 

7. Standard WiFi Ad

-

hoc connec-

tion on your wireless device:

 

15 seconds after the A034

-

B has 

 

powered up, scan for a WiFi net-
work with an SSID similar to 

QK

-

A034xxxx

’. 

 

Connect to 

QK

-

A034xxxx

’ 

with 

the default password: 

88888888

’. 

 

 

Chart software: 

in your chart soft-

ware, set the protocol to 

TCP

’, 

IP 

address to 

192.168.1.100

’ 

and 

port number to 

2000

’ 

 

 

For Station mode WiFi or to disable WiFi, use the Configuration software. (see below)

 

 

8. Follow your marine software/APP instructions 

for adding input/output data sources. 

 

A general overview can be found in the A034

-

B manual.

 

Set

-

Up guide

 

QK

-

A034

-

B

 

BI

-

DIRECTIONAL  MULTIPLEXER 

 

NMEA 2000 

-

 NMEA 0183 

-

 WIFI 

-

 USB

 

WITH FILTERING, ROUTING AND SEATALK

1

 CONVERTER

 

All products are CE, RoHS certified

 

More information at www.quark

-

elec.com

 

Please recycle your packaging 

 

Reviews: