background image

6.  WiFi Ad-hoc connection 
On your device (phone, laptop etc.):  

15 seconds after the A033 has powered up, you 
can scan for a WiFi network with an SSID similar to 
‘QK-A033xxxx’. Connect to ‘

QK-A033xxxx

’ with 

the default password: ‘

88888888

’.  

Chart software: 

in your chart software, set the 

protocol to ‘

TCP

’, IP address to ‘

192.168.1.100

’ 

and port number to ‘

2000

’  

For Station mode WiFi setup, use the Configura-
tion software. (see below)

 

Disclaimer: 

This product is designed to aid navigation and should be used to augment normal navigational 

procedures and practices. It is the user’s responsibility to use this product prudently. Neither Quark-elec, nor 
their distributors or dealers accept responsibility or liability either to the product user or their estate for any 
accident, loss, injury or damage whatsoever arising out of the use or of liability to use this product. 

Email: 

info@quark-elec.com

 

V1.1(10/19) 

QK-A033 

Note: 

SeaTalk™ is a registered trademark of Raymarine. 

USING THE CONFIGURATION SOFTWARE (WINDOWS): 

WiFi can be changed from Ad-hoc (default) to  Station mode or Standby. 
Station mode 

is configured by inputting your router/access point’s details into the Configuration 

software.  (once configured, the correct settings must be entered into your chart software.) 

 

Filtering: using the black list function 

If desired, selected NMEA sentences can be blocked  from chosen input/s, using the ’black list ‘ 
field. Remove the ‘$’ or ‘!’ from the 5 digit NMEA talker and sentence identifier and insert sepa-
rated by commas. For example to block ‘!AIVDM’ and ‘$GPAAM’ enter ‘AIVDM,GPAAM’ . 
Up to 8 sentences types can be filtered from each input port.  If blacklisting Seatalk  data, block 
the corresponding NMEA message (see the manual for a full list of converted messages). 

 

Routing the Seatalk and NMEA sentences. 

As a default, all inputs’ data (excluding any filtered data) is routed to all outputs (NMEAx2, WiFi 
and USB). Data can be routed to limit the data flow to only certain output/s by un-ticking the 
corresponding boxes in the Configuration software. 

 

NMEA Baud rates: 

Default Baud rates are set to: 

 

NMEA IN 1 and 2: 4800bps 

 

NMEA IN 3: 38400bps  

 

NMEA OUT 1: 4800bps  

 

NMEA OUT 2: 38400bps  

These can be changed as required. 

 

USB input: 

The USB connection is 2 way as standard, no additional configuration required.  Man-

ual  NMEA input via USB is also possible through the configuration software. A good understand-
ing of NMEA sentence structure is required for this additional function. 

SET-UP GUIDE 

QK-A033 

WIFI/USB/NMEA 0183 MULTIPLEXER 

WITH SEATALK™  CONVERTER 

All products are CE, RoHS certified 

More information at www.quark-elec.com 

Please recycle your packaging  

Reviews: