AF400m HEPA Air Purifier
Instruction Manual
------------------------------------------------------------------------------------------------------------------------------------------------------------
INTRODUCTION
Congratulations! You are now owner of a QUATRO purifier, an advanced effective purifier, designed specifically for the human respiratory system. You can expect
a noticeable improvement in air quality as the unit begins the process of reducing microscopic airborne particulate, dust, pollen etc.
SAFETY PRECAUTION
Read the instructions contained within this manual before operating this unit. Keep this manual, as it contains information for proper operation and maintenance.
Keep all fastening hardware tight to ensure that the unit is in safe working condition. Familiarise yourself with the way in which filters are installed & replaced. All
filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat
proper grounding. If servicing the unit, be careful not to touch the motor as soon as it has been turned off. Motor can be hot and can cause injury
.
ALWAYS UNPLUG FROM SUPPLY BEFORE DOING ANY MAINTENANCE OR FILTER SERVICE
Upon arrival, inspect unit for either visible or concealed damage. Damage should be immediately reported to the transport company.
PRE START-UP CHECKLIST
a)
All filters are present and are correctly installed prior use;
b)
Labels and serial numbers are present for future identification;
c)
Verify that power supply is compatible with equipment. Check the unit is plugged into a grounded receptacle;
d)
The casters (wheels) must be secure in place prior the moving the air purifier.
START-UP
a) Place the air purifier in the desired area for use. Ensure all filters are installed;
b) Make sure the air intake area (bottom) is not obstructed in any way.
c) Insert male end of power cord into grounded circuit;
d) Turn power toggle switch to "HIGH" position.
e) Air purifier should now be functioning and operational;
WARNING: DO NOT OPERATE UNIT UNLESS ALL FILTERS ARE IN PLACE.
FILTER MAINTENACE PROGRAM
Part No.:
Stage #
Filter Type
Replacement Time
F071-BX(6/bx)
Bottom
Dust Filter
Every 3-6 months
F075
Top
Hepa Filter
Every 12-24 months
FILTER REPLACEMENT - AF400m
Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures ensuring the unit
will provide trouble-free operation for years to come. The purifier is designed to allow quick access to the filters, blower/motor and control panel assembly.
Stage I
(Bottom) DUST FILTER p/n F071-BX
- Change the dust filter every three months (or more) depending on the dust level in the area;
- To do this, turn OFF the unit. Unplug from wall outlet, unscrew the (2) thumbscrews at the base of the unit;
- Remove the door, replace filter, ensure you close door prior tighten thumbscrews prior to operation;