Installation, Operation and Maintenance Instructions

– Read and Save These Instructions –

This manual is provided to acquaint you with the dehumidifier so that 
installation, operation and maintenance can proceed successfully.  
Ultimate satisfaction depends on the quality of installation and a  
thorough understanding of this equipment. The dehumidifier is built 
around tested engineering principles and has passed thorough internal 
and 3rd party inspections for quality of workmanship and function.

Quest 

DRY 150

Installation, Operation and Maintenance Instructions

4201 Lien Rd.
Madison, WI 53704 

1-800-533-7533

www.QuestProtect.com sales@QuestProtect.com 

– Read and Save These Instructions –

Specifications subject to change without notice.

TS-826

05/15

1

Quest 

DRY  

70

Water Removal Rate (Pints/Day) 

 

65 pints 

80˚F, 60% (AHAM)

 

Quest 

DRY 

70

FEATURES

:

• Energy Star Listed
• Large Capacity
• MERV-11 Filtration
• Low Temperature Operation
• Carbon Filtration
• Optional Equipment  

– Ducting Kit 
– Hang Kit 
– Caster Kit 
– Condensate Pump

quest

quest

Summary of Contents for 4033750

Page 1: ...ssed thorough internal and 3rd party inspections for quality of workmanship and function Quest DRY150 Installation Operation and Maintenance Instructions 4201 Lien Rd Madison WI 53704 1 800 533 7533 w...

Page 2: ...ate Pump Kit 6 4 4 Ducting 6 4 4A Fresh Air Supply Air 7 4 4B Ducting for Fresh Air Option 7 4 4C Installation in a Basement or Crawlspace 8 4 4D Installation in an Attic 8 4 4E Installation in a Stru...

Page 3: ...ault Circuit Interrupt outlet DO NOT use the device as a bench or table DO NOT place the device directly on structural members A drain pan MUST be placed under the unit if installed above a living are...

Page 4: ...nce at 80 F and 60 RH Water Removal 65 pints day Efficiency 4 5 Pints kWh Air Filter MERV 11 Efficiency Standard 70 Efficient ASHRAE Dust Spot Test Size 12 x 12 x 1 Power Cord 8 110 120 VAC Grounded D...

Page 5: ...nded with a hang kit 4028111 or a suitable alternative from structural members as long as the suspending assembly supports the Quest Dry 70 s base in its entirety Do not hang the Quest Dry 70 from the...

Page 6: ...minal pipe thread adapter to the drain pan It is necessary to assemble your own drain pipe assembly utilizing 3 4 PVC pipe to get the condensate to a floor or other drain Pipe is commonly available in...

Page 7: ...ocated on the top of the unit Align screw holes and snap the panel onto the base 4 Secure the exhaust panel to the base by replacing the six 6 screws For the ideal installation draw air from the centr...

Page 8: ...red before entering the building 2 Outside air will be dehumidified before entering the building if the Quest Dry 70 is running in dehumidification mode 3 Drawing air from outside and blowing inside a...

Page 9: ...area of the structure Optional Duct the supply of the Quest Dry 70 to a 8 x 8 x 8 tee damper that is 20 open to the crawlspace if desired Duct the other side of the tee to the air supply of the exist...

Page 10: ...ooms den etc By ducting this way the air inside the structure will circulate through the Quest Dry 70 to be filtered and dehumidified A 6 diameter duct is recommended for branches to the bedrooms A 8...

Page 11: ...be sure the built in dehumidistat is set to the off position by turning it counterclokwise until it stops Failure to do so may cause the unit to sense the humidity from the wrong area WARNING DO NOT...

Page 12: ...G Allowing yellow wire to contact red or white wire will destroy the transformer Dehumidifier on Connect yellow and blue wires Fan only on Connect yellow and green or brown wires Accessory power 24vol...

Page 13: ...ge to the unit and invalidate the product warranty 6 2 Optional Fresh Air Intake Check and clean the screen on the outdoor fresh air intake port seasonally The screen may become plugged during the sea...

Page 14: ...quest quest 1 800 533 7533 Quest DRY 70 Installation Operation and Maintenance Instructions 14 www QuestProtect com sales QuestProtect com FOR HVAC INSTALLER ONLY 7 Wiring Diagram...

Page 15: ...unnecessarily on the defrost control FOR OWNER ROUTINE MAINTENANCE 8 Optional Parts List Quest Dry 70 Part No Description 4030671 Filter MERV 11 4030113 Pump Kit 4029908 Hang Kit 4023647 8 Gravity Da...

Page 16: ...erant during normal operation A flooded evaporator should maintain nearly constant pressure and temperature across the entire coil from inlet to outlet The mixture of gas and liquid refrigerant enter...

Page 17: ...10 Optional Condensate Pump Safety Switch open Unit Test to determine problem 1 Detach field control wiring connections from main unit 2 Connect the yellow and green pigtails from the main unit togeth...

Page 18: ...emain closed when the ventilation timer is not activated to prevent over ventilating the structure when the unit is dehumidifying or recirculating the indoor air The electric ventilation timer operate...

Page 19: ...present proof of purchase lease upon request by use of the warranty card receipt invoice or other reasonable and reliable means The end user is responsible for normal care This warranty only applies...