GEARMOTOR
FOR GARAGE DOORS
WARNING!! Before installing, thoroughly read this manual that is an integral
part of the pack
BOXTER
USER MANUAL
V03/2016
ENG
Page 1: ...GEARMOTOR FOR GARAGE DOORS WARNING Before installing thoroughly read this manual that is an integral part of the pack BOXTER USER MANUAL V03 2016 ENG...
Page 2: ...upply 230Vac 24Vdc Motor power 250 W 50W Motor rpm 1400 1800 Capacitor 12 5 F Average power consumption 1 3 A 3 A Mechanical release for emergency operation Indoor use with possibility of outdoor use...
Page 3: ...d testing operations must be performed only by qualified personnel in order to ensure the proper and safe operation of the automated door The manufacturer declines all responsibility for damages cause...
Page 4: ...sting arm of the door Make sure there are at least 20 mm of space between the door frame and the box of the counterweights Note If you are not able to use the straight telescopic arm use the curved on...
Page 5: ...he transmission tube to the straight or curved arm M 50 100 mm 50 100 mm Straight or curved arm Place and securely fix the tube support to the door frame at a distance between 50 and 100 mm downwards...
Page 6: ...F THE LATERAL FIXING PLATES LIMIT SWITCH ADJUSTMENT Close the door Place the limit switch C in order to touch the lever of the microswitch of the closing limit switch and tigthen the screw Open the do...
Page 7: ...TOMATION WITH NON PROJECTING DOOR Place and securely fix the tube support to the door frame at a distance of 110 mm under the center of the door look at fig 7 8 The rotation axis of the motor must be...
Page 8: ...am is interrupted Check the connection remove any obstacle across the beam On giving a command with the remote control the door doesn t open but works with the key command The remote control has not b...
Page 9: ...ts of the regulations Electromagnetic Compatibility Directive 2004 108 EC Low Voltage Directive 2006 95 EC Machinery Directive 2006 42 EC and their amendments and modifications and with the regulation...
Page 10: ...ific national technical regulations have been followed EN 12453 EN 12445 on Industrial Commercial and Residential Gates and Doors Safe Use of Motorized Doors Requirements and Classification Test Metho...
Page 11: ...on are not comlplied with ATTENTION il vous pla t attentivement ce manuell installation QUIKO d cline toute responsabilit cas de non conformit ces glements Apparecchiatura di comando 1 Motore 230Vac C...
Page 12: ...C COM N C 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COM Start Stop 2 1 7 6 Example wiring selector CONTACT NO CONTACT NC 1 2 3 4 ON PROG RADIO PED START ANT STOP LSC 24Vac M LSO STOP LSC LSO...
Page 13: ...stop at close limitswitch if you chose an automatism without limitswitches must give a further impulse to fix the stopping point of the stroke If you choose to have the AUTOMATIC CLOSING OPTION 2 IN...
Page 14: ......
Page 15: ......
Page 16: ...Quiko Italy Via Seccalegno 19 36040 Sossano VI Italy Tel 39 0444 785513 Fax 39 0444 782371 info quiko biz www quikoitaly com...