background image

 

WARNING: 

After learning the first code the system will only accept that code family (if the first is Rolling all the others will 

have to be Rolling). 

 

MEMORY RESET 

For cancelling all codes, press and hold the P1 button (red led prog will turn on) until the LED turns off again. When the 
button is released, the LED flashes. 
 

WORKING TIME SETUP FOR 2 LEAFS GATES 

MAKE SURE THE GATE IS CLOSED 

SET DIP10 SW1 TO OFF 
Turning the DIP1 SW1 to "ON" enables the self-learning timing: 
Pressing the START or the first channel of a previously learned remote control starts opening the gate (otherwise reverse 
the terminals 1-2 and 3-4 wires). From this point on, the microprocessor starts to count the working time (programming 
LED lights up) 
The  first  leaf  starts  opening,  after  desired  displacement  time,  press  the  TX  to  start  the  second  leaf,  when  the  first  leaf 
arrives at the desired position, give another "START" command and it stops. When the second leaf arrives In the desired 
position give another “START” command and it also stops (if electrical or mechanical limit switches are used and obstacle 
sensing is enabled, there is no need to give a start impulse when the leafs have opened). Flashing lamp lights off and 
from  this  moment  the  board  counts  the  automatic  closing  time.  When  you  think  enough  pause  time  has  passed,  press 
"START": the second leaf start closing, once the displacement time has passed, give another START signal and also the 
first leaf starts closing. When the second leaf arrives at the desired position give another "START" command to stop it. 
When  the  first  leaf  arrives  at  the  desired  position  give  another  "START"  command  and  it  also  stops  (if  electrical  or 
mechanical limit switches are used and obstacle sensing is enabled, there is no need to give a start impulse when the leaf 
has closed). The flashing lamp lights off. Programming LED flashes. It is necessary at this point to put the DIP1 to the 
"OFF" position (the LED goes off). Now everything is ready to be able to start the opening gate again. 
The  control  unit  is  also  designed  to  handle  the  partial  opening  (pedestrian)  via  the  2nd  channel  of  the  remote  control, 
previously memorized, or the PEDESTRIAN START input. 

To program the pedestrian time, repeat setup as above using the pedestrian start input or the 2

nd

 button of the 

TX. 

 

WORKING TIME SETUP FOR 1 LEAF GATES 

MAKE SURE THE GATE IS CLOSED 

SET DIP10 SW1 TO ON 
Turning the DIP1 SW1 to "ON" enables the self-learning timing: 
Pressing the START or the first channel of a previously learned remote control starts opening the gate (otherwise reverse 
the terminals 1-2). From this point on, the microprocessor starts to count the working time (programming LED lights up) 
The leaf starts opening. When it arrives at the desired position, give another "START" command and it stops. (if electrical 
or mechanical limit switches are used and obstacle sensing is enabled, there is no need to give a start impulse when the 
leaf has opened). Flashing lamp lights off and from this moment the board counts the automatic closing time. When you 
think enough pause time has passed, press "START": the leaf start closing. When it arrives at the desired position give 
another  "START"  command  and  it  stops  (if  electrical  or  mechanical  limit  switches  are  used  and  obstacle  sensing  is 
enabled, there is no need to give a start impulse when the leaf has closed). The flashing lamp lights off. Programming 
LED flashes. It is necessary at this point to put the DIP1 to the "OFF" position (the LED goes off). Now everything is ready 
to be able to start the opening gate again. 
-------------------------------------------------- -------------------------------------------------- --------------------------------------------------  

WARNINGS 

When wiring and inserting the Radio Module, the equipment must not be powered. 
The use of this equipment must strictly follow and comply with the technical standards of reference. Installation and / or 
maintenance must only be carried out by qualified personnel in accordance with applicable laws. The manufacturer can 
not be held liable for any damage caused by improper use and / or unreasonable use. Improper installation or incorrect 
use of the product may compromise the safety of the system, all the materials present in the packaging must not be left to 
the reach of children as a source of danger.

 

-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------

 

DISPOSAL: 

keep the product out of the reach of children. Do not throw the 'apparatus together with ordinary municipal waste as a symbol 

marked on the product. (European Directive 2002/96/EC) 

 

 

 

 

 

And 'the responsibility of the owner dispose of electrical product collection centers according to the specifications of public bodies. 

EC DECLARATION OF CONFORMITY

 ' 

Below, we declare that the product meets all the requirements for the type of product required by the regulations and directives 2004/108/EC, 
2006/95/EC, through the use of standards published in the Official Journal of the European community: 
SFT norm: EN 60950:2006 
Norma SFT: 
EMC norm: EN301489-3 V1.4.1 
EMC standard: 
It also declares that it is forbidden to put the above-mentioned products on the market before the machine has these rules and it is found to 
comply with the conditions required by Directive 89/392 EEC and national laws applies, that is, until the material, to which this declaration , 
does not form a whole with the final machine. 

 

 

 

www.quikoitaly.com

 

           Made in Italy

 

QK-CE24BATR         V02 

The 

QK-CE24BATR

 electronic equipment is designed for automation of 

LOW VOLTAGE 12V or 24V  DC motors

. For 

swinging and sliding gates.  

INSTALLATION NOTES 

1) Before proceeding with installation, a thermal or differential magnet switch with a maximum capacity of 10A must be set 
upstream  of  the  system.  The  switch  must  ensure  omnipolar  separation  of  the  contacts,  with  an  opening  distance  of  at 
least 3 mm 
2) Differentiate and separate power cables (minimum section 1.5mm2) from signal cables that can be 0.5mm2.

 

 

 

         
                                              

    

  

 

 

 
 

 
 
 
 
 
 
 

 
 
 

SIGNAL LED'S: 

All inputs on the M2 terminal block 
are filtered by optoisolators that 
eliminate low voltage disturbs. If a 
dip-switch input is excluded, the 
corresponding LED will not light 
up, but if it is not connected to a 
terminal block

 

with a bridge on the 

"com", this will light up.

 

CAUTION: 

For 24V systems, if a transformer other than that 

provided by the factory (recommended) is used, the power 
Of the output on the secondary must NOT exceed 24 VAC. 
The power output must NOT be less than 150VA 

TECHNICAL FEATURES 

- 12Vac or 24Vac electronic board power 
supply 
- 230Vac toroidal transformer supply 
- 12Vcc electric lock 
- Courtesy light 12Vdc or 24Vdc 
- No. of motors: 1 or 2 Max 150W total 
- Battery 12Vdc or 24Vdc 
- Flashing: 12Vdc or 24Vdc 
- 12Vdc or 24Vdc lamp 
- Photocells: 12Vdc or 24Vdc 
- Operating temperatures -20 +

 

55 ° C

 