PAGE 2 (TWO - INSIDE DPS)
Meteor Floodlights with PIR
Product Codes:
MET10PIR-60, MET20PIR-60, MET30PIR-60 &
MET50PIR-60
Box Contents -
1 x Meteor Floodlight with PIR
Dimensions:
MET10PIR-60: L: 158 x W: 120 x D: 54mm
MET20PIR-60: L: 159 x W: 140 x D: 54mm
MET30PIR-60: L: 180 x W: 177 x D: 54mm
MET50PIR-60: L: 215 x W: 223 x D: 54mm
Material:
Body - Die-cast Aluminium, Lens - Polycarbonate
Working
Temperature:
Standard: -20°C - 45°C
Included:
Integral PIR Sensor
1m Pre-wired Cable
Steel Mounting Bracket
Safety Warning
•
The installation should be carried out
by a qualified electrician in compliance
with the current edition of the IEE
Wiring Regulations.
•
Prior to installation, carry out the
necessary risk assessment considering
the people who could be at risk,
the level of risk and the precautions
required to control the risk
•
Ensure that the circuit supply is
isolated either by the circuit supply
fuse being removed or the applicable
circuit breaker being turned off before
installation or any maintenance.
•
Check the total load on the circuit
ensuring the luminaire does not exceed
the rating of the circuit cable, fuse or
circuit breaker.
•
Long-term use and voltage fluctuations
can reduce the life span of the fitting.
•
If the fitting incorporates control gear,
ensure careful sizing to avoid instances
of nuisance tripping of the protective
device used in the installation.
•
Follow the provided installation
instructions, using the fixings supplied
or recommended.
•
Keep out of reach of children.
180-
240V
IP65
2
YRS
GUARANTEE
INSTALLATION
INSTRUCTIONS
IK07
PAGE 1 (FRONT PAGE)
Specification
10-
50
WATT
LED
6000K
900-
4500LM
Automatic Circuit Breaker Type:
B6
B10
B13 B16
B20
C10 C13 C16
C20
Rated Current:
6A
10A
13A
16A
20A
10A
13A
16A
20A
Cable (mm):
1.5
1.5
1.5
1.5
2.5
1.5
1.5
1.5
2.5
MET10PIR-60
150
250
325
400
500
250
325
400
500
MET20PIR-60
75
125
163
200
250
125
163
200
250
MET30PIR-60
60
100
130
160
200
100
130
160
200
MET50PIR-60
30
50
65
80
100
50
65
80
100
Maximum Fittings Per Circuit
1.
Ensure there is adequate free air circulation of at least 100mm around the fitting. All fittings run hot. It is the installer’s responsibility to consider any fire
risk and take appropriate precautions.
2.
The nearest illuminated surface must be at least 0.5m from the front of the fitting.
3.
Check for concealed cables before drilling any fixing holes.
4.
Fix the bracket to a wall or similar hard surface.
5.
Connect the cable to the power supply.
6.
NOTE: 10W & 20W Versions are 3 wire connection. To switch on the fitting and over-ride the PIR, switch on the mains supply via a local switch, then off and
then on again in rapid succession. To reset the PIR to normal operation, turn the mains supply off via the local switch, then turn on again after 3 seconds.
Installation Instructions
Wmm
Dmm
Lmm