INSTALLATION INSTRUCTIONS
RAB DESIGN LIGHTING INC.
www.rabdesign.ca
1
VFL-LED
ELECTRICAL SHOCK HAZARD
READ, UNDERSTAND
, and
FOLLOW
these instructions
before installing the equipment.
WARNING
SAFETY
Proper grounding is required to ensure personal safety.
Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering.
Do not use this equipment for anything other than its intended purpose.
Servicing this equipment should be performed by qualified service personnel.
Save these instructions.
INSTALLATION
KNUCKLE MOUNT
The fixture has ½” NPS locking swivel knuckle that is suitable for mounting with a junction box
or into a junction box cover (sold separately).
NOTE: Use appropriate size junction box
and/or junction box cover depending on the size of fixture being mounted.
Pull the wires into the hole of the junction box or cover (not provided).
Connect the wires properly in the junction box or cover. See Wiring Diagram.
Mount the fixture to junction box or cover by screwing the locking swivel knuckle into
junction box or cover.
Loosen the screw on swivel portion of the knuckle, adjust the fixture to a suitable
orientation, and then tighten the screw.
YOKE MOUNT
DO NOT remove the yoke from the fixture.
Mount the fixture to the wall with appropriate screws (not provided).
Pull the wires into the junction box (not provided).
Connect the wires properly in the junction box. See Wiring Diagram.
Loosen the screws on yoke, adjust the fixture to a suitable orientation, and then tighten
the screws.
SLIP FIT MOUNT
Loosen the angle adjustment screw on swivel portion of the slip fit, adjust the fixture to a
suitable orientation, and then tighten the screw.
Loosen the 4 set screws.
Connect the wires properly from the wiring access. See Wiring Diagram.
Carefully place the fixture on a post with a diameter of 2 3/8” (60mm).
Tighten set screws to secure fixture to post.
WIRING
Check that the line voltage is correct.
Connect fixture
GROUND
(green) wire to power supply
GROUND
(green) wire.
Connect fixture
WHITE
wire to power supply
NEUTRAL
wire.
Connect fixture
BLACK
wire to power supply
LINE
wire.
Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box). Failure to do so could result in serious
injury or death. Only qualified electricians should install this fixture and the installation MUST conform to the Canadian
Electrical Code Part I and all local codes and ordinances. Ensure that only proper tools, materials, and equipment are used to
complete the installation.