background image

 

 
INSTALLATION INSTRUCTIONS 

RAB DESIGN LIGHTING INC. 

www.rabdesign.ca 

 

VFL-LED 

ELECTRICAL SHOCK HAZARD 

READ, UNDERSTAND

, and 

FOLLOW 

these instructions 

before installing the equipment. 

WARNING

SAFETY

 

 

Proper grounding is required to ensure personal safety. 

 

Fixture should be mounted in locations where unauthorized personnel will not readily subject it to tampering. 

 

Do not use this equipment for anything other than its intended purpose. 

 

Servicing this equipment should be performed by qualified service personnel. 

 

Save these instructions. 

 

INSTALLATION 

KNUCKLE MOUNT 

The fixture has ½” NPS locking swivel knuckle that is suitable for mounting with a junction box 
or into a junction box cover (sold separately).  

NOTE: Use appropriate size junction box 

and/or junction box cover depending on the size of fixture being mounted. 

 

Pull the wires into the hole of the junction box or cover (not provided). 

 

Connect the wires properly in the junction box or cover. See Wiring Diagram. 

 

Mount the fixture to junction box or cover by screwing the locking swivel knuckle into 
junction box or cover. 

 

Loosen the screw on swivel portion of the knuckle, adjust the fixture to a suitable 
orientation, and then tighten the screw. 

 

YOKE MOUNT 

DO NOT remove the yoke from the fixture. 

 

Mount the fixture to the wall with appropriate screws (not provided). 

 

Pull the wires into the junction box (not provided). 

 

Connect the wires properly in the junction box. See Wiring Diagram. 

 

Loosen the screws on yoke, adjust the fixture to a suitable orientation, and then tighten 
the screws. 

 

SLIP FIT MOUNT 

 

Loosen the angle adjustment screw on swivel portion of the slip fit, adjust the fixture to a 
suitable orientation, and then tighten the screw. 

 

Loosen the 4 set screws. 

 

Connect the wires properly from the wiring access. See Wiring Diagram. 

 

Carefully place the fixture on a post with a diameter of 2 3/8” (60mm). 

 

Tighten set screws to secure fixture to post. 

 

WIRING 

 

Check that the line voltage is correct. 

 

Connect fixture 

GROUND

 (green) wire to power supply 

GROUND

 (green) wire. 

 

Connect fixture 

WHITE

 wire to power supply 

NEUTRAL

 wire. 

 

Connect fixture 

BLACK

 wire to power supply 

LINE

 wire. 

 

 

Disconnect the Electrical supply power at the service panel (fuse or circuit breaker box).  Failure to do so could result in serious 
injury or death.  Only qualified electricians should install this fixture and the installation MUST conform to the Canadian 
Electrical Code Part I and all local codes and ordinances.  Ensure that only proper tools, materials, and equipment are used to 
complete the installation. 