INSTRUCTIONS
X17™
XFU 3-WAY FIELD ADJUSTABLE FLOODLIGHT
SELECTABLE PHOTOCELL INSTALLATION
RAB Lighting is committed to creating high-quality, affordable, well-designed and energy-efficient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: marketing@rablighting.com
X17 XFU 80/60/40W Trunnion
X17 XFU 80/60/40W Knuckle
KNUCKLE MOUNT
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB fi xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is
required for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON
FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING: Make certain power is OFF before installing or maintaining fi xture. No user serviceable parts inside.
WARNING: Do not use an electric generator to test LED fi xtures.
WARNING: Min 75°C SUPPLY CONDUCTORS.
1. Secure the fi xture to a 1/2” NPS hole in the junction box or
landscape post as shown in Fig. 1. Seal arm thread using
Tefl on® tape or silicone sealant.
2. Make appropriate wire connections per NEC in an approved
enclosure
(not included)
see Fig. 12.
3. The
Knuckle Arm
allows 180° of vertical aiming adjustment
depending on the mounting position as shown in Fig. 2.
TRUNNION MOUNT
Trunnion Mount accessory included.
To Install the Trunnion:
1. Remove the pre-installed
Knuckle Mount
by loosening the
Socket Head Screw
and removing
Bracket A
as shown in Fig. 3.
2. Loosen 2
Socket Head Screws
to remove
Bracket B
as shown in
Fig. 4.
3. Insert
Fixture
wires through the
Trunnion
and align with
Fixture
screw holes. Secure the
Trunnion
to the
Fixture
by tightening 2
Socket Head Screws
as shown in Fig. 5.
Fig: 1
Fig: 3
Fig: 4
Fig: 5
Fig: 6
Fig: 2
Pole
Screws
Tenon
Wire
Slipfitter Mount
Fixture
90°
M6*16 socket head screws
M8*40 socket head screw
Bracket A
Bracket B
M6*16 socket head screws
M8*40 socket head screw
Bracket A
Bracket B
Pole
Screws
Tenon
Wire
Slipfitter Mount
Fixture
90°
M6*16 socket head screws
M8*40 socket head screw
Bracket A
Bracket B
Pole
Screws
Tenon
Wire
Slipfitter Mount
Fixture
90°
Knuckle Arm
Trunnion
Angle Lock Screw
Pivot Bolt
Socket
Head Screw
(2)
Bracket B
Socket
Head Screw
(2
)
Socket Head Screw
Pole
Bracket A
To ensure weatherproof seal, apply weatherproof silicone sealant
around the edge of the Junction Box
(not supplied)
. This is especially
important with an uneven wall surface.
X17 XFU 80/60/40W Slipfi tter