background image

 

 
 

 
 
 
 
 
 
 
 
 
 

Zond Aero 500  

Ground Penetrating Radar 

 

USER’S MANUAL 

 
 
 
 
 
 
 
 

 

Riga, 2021 

 

 

Darzauglu Str. 1-105, Riga LV-1012, Latvia 

Phone/Fax: (+371)-67141041 

E-mail: 

radsys@radsys.lv

 

Web: 

www.radsys.lv 

 
 

Summary of Contents for Zond Aero 500

Page 1: ...Zond Aero 500 Ground Penetrating Radar USER S MANUAL Riga 2021 Darzauglu Str 1 105 Riga LV 1012 Latvia Phone Fax 371 67141041 E mail radsys radsys lv Web www radsys lv...

Page 2: ...8 7 A h which is built in to the shockproof case The status of the battery voltage and percentage of the battery level is transmitted via TCP IP protocol during data acquisition and is displaying by...

Page 3: ...3 Connect the survey wheel cable coming out from the shockproof case control panel to the control unit Fig 1 Zond Aero 500 GPR Fig 2 Zond Aero 500 GPR in the shockproof case...

Page 4: ...l panel with mounted Zond Aero 500 GPR Fig 4 Survey wheel mounted on the shock proof case 2 2 First run of the Zond Aero 500 GPR 1 Place the Zond Aero 500 GPR in a working position as it shown on Fig...

Page 5: ...onfiguring the computer to connect with Zond 12e GPR Control Unit and paragraph 6 What to Do Immediately After Installation 3 Run Prism2 software its main menu is shown on Fig 5 Fig 5 Main menu of Pri...

Page 6: ...position of the signal choose the Pulse delay menu and press A key on keyboard to start automatic adjustment Press the Enter and then Close setup menu after pulse delay adjustment is finished Fig 7 S...

Page 7: ...too short it is possible to add one more cable using the coupler included in accessories kit Fig 8 Zond Aero 500 GPR data acquisition Right after SETUP dialog box is closed button START activates Pres...

Page 8: ...than 35 C it is not recommended to leave the instrument in place where it can be affected by the direct sun light 4 TRANSPORTATION RULES 4 1 In case of observing of rules of packaging of the instrumen...

Page 9: ...ting to Electromagnetic Compatibility and Radio Spectrum Matters 99 5 EC Short range devices Ground and Wall Probing Radars applications Low voltage Directive 73 23 EEC and the Amendment Directive 93...

Page 10: ...user s authority to operate the equipment Operation of this device is restricted to law enforcement fire and rescue officials scientific research institutes commercial mining companies construction c...

Page 11: ...only for Domestic United States users The Federal Communications Commission FCC requires that all users of GPR who purchased antennas after July 15th 2002 register their equipment and areas of operati...

Page 12: ...nt d Industrie Canada Fran ais Ce dispositif est conforme la norme CNR 220 d Industrie Canada applicable aux appareils radio exempts de licence Son fonctionnement est sujet aux deux conditions suivant...

Page 13: ...13 9 OUR ADDRESS Radar Systems Inc Darzauglu Street 1 105 Riga LV 1012 LATVIA Phone 371 67141041 E mail radsys radsys lv...

Reviews: