VBD 702-2

-1

 (10.19)

Product description

Intended use

Electrical connection

 DANGER!

Risk of fatal electric shock when touching electrical 

components.

The connection of the tubular motor to the universal

�����������������������������

to the mains may only be undertaken by an authorised

�����������

Carry out all connection work only in an isolated, de-ener-

gised state.

Disconnect all phases of the mains power lead and se-

cure it to prevent any reconnection.

Check that the system is de-energised.

Intended use

Use the universal setting cable only for commissioning, end 

point setting or adjusting the end points of RADEMACHER 

tubular motors.

Improper use

Do not use the universal setting cable:

for the permanent control of a tubular motor.

for the connection and control of other electrical appliances.

T�����������

Operating voltage: 

230 V / 50 Hz

Max. switching capacity:

6 (4) A / 250 V AC 1E4

Permissible 

ambient temperature:

0 to 40°C

Permissible 

storage temperature:

-10°C to +60°C /

Relative humidity: max. 90%

Protection class:

II 

(only for use in dry rooms)

The universal setting cable is designed for commissioning, end 

point setting or adjusting the end points of RADEMACHER 

tubular motors.

Support for the new C-line, M-line and 

S-Line tubular motor generation with:

Sensor function

Single-hand operation possible

Connection with the same colours

Manual end point setting

Support for current RADEMACHER tubular motors:

The current generation of RolloTube I-line (DuoFern), 

X-line motors are also supported.

You can obtain further information on 

our support for the current 

RADEMACHER tubular motors on our 

website www.rademacher.de or 

simply scan this QR-Code:

Button 1

Button 2

Button 3

C-line / M-line

S-line

Button 1

Direction of travel I / II

Button 2

Set button

Button 3

No function

Continuous phase

Pin assignment

The connection is made with the same colours as the motor con-

necting cable of the respective RolloTube tubular motor.

Before you begin the work, please read the detailed  

operating manual of the respective tubular motor and 

follow all the safety instructions and installation  

instructions.

black  

L1

 

 (Direction of travel 1)

brown 

L1

 

 (Direction of travel 2)

blue 

N

 

Neutral terminal 

green/yellow

PE

  Earth 

grey or white 

varies depending on motor

 

1.

Open the terminal contacts by pressing the plungers and

connect all the wires of the motor cable with the same col-

ours and corresponding to their functions.

2.

Then insert the mains plug into the mains socket.

Button assignment

Universal setting cable for tubular motors

Translation of the Original Operating Manual for setting the 

RolloTube C/M/S-line tubular motors

Item no. 9600 00 86 