The test report only allows to be revised within three years from its original issued date unless further standard or the requirement was noticed. 

− 

This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client.  Intertek's responsibility and liability 
are limited to the terms and conditions of the agreement.  Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for 
any loss, expense or damage occasioned by the use of this report.  Only the Client is authorized to permit copying or distribution of this report and then only in its 
entirety.  Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by 
Intertek.  The observations and test results in this report are relevant only to the sample tested.  This report by itself does not imply that the material, product, or 
service is or has ever been under an Intertek certification program. 

 

Intertek Testing Services Hong Kong Ltd.

 

2/F., Garment Centre, 576 Castle Peak Road, Kowloon, Hong Kong. 

Tel: (852) 2173 8888  Fax: (852) 2785 5487 Website: www.hk.intertek-etlsemko.com

 

 
 
 

RadioShack Corporation 

 
 

Application 

For 

Certification 

(FCC ID: AAO120495) 

 

Transmitter 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
HK08061007-1 
TC/el 
July 28, 2008 
 
 

Summary of Contents for AA0120495

Page 1: ... authorized to permit copying or distribution of this report and then only in its entirety Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material product or service must first be approved in writing by Intertek The observations and test results in this report are relevant only to the sample tested This report by itself does not imply that the material...

Page 2: ...IT 1 General Description EXHIBIT 2 System Test Configuration EXHIBIT 3 Emission Results EXHIBIT 4 Equipment Photographs EXHIBIT 5 Product Labelling EXHIBIT 6 Technical Specifications EXHIBIT 7 Instruction Manual EXHIBIT 8 Miscellaneous Information EXHIBIT 9 Confidentiality Request ...

Page 3: ... 47 CFR 0 457 d 1 ii Yes No X If yes defer until date Company Name agrees to notify the Commission by date of the intended date of announcement of the product so that the grant can be issued on that date Transition Rules Request per 15 37 Yes No X If no assumed Part 15 Subpart C for intentional radiator the new 47 CFR 05 04 07 Edition provision Report prepared by Ho Wai Kin Ben Intertek Testing Se...

Page 4: ...ort Equipment List and Description 6 3 0 Emission Results 8 3 1 Field Strength Calculation 9 3 2 Radiated Emission Configuration Photograph 11 3 3 Radiated Emission Data 12 3 4 Conducted Emission Configuration Photograph 16 3 5 Conducted Emission Data 16 4 0 Equipment Photographs 17 5 0 Product Labelling 19 6 0 Technical Specifications 21 7 0 Instruction Manual 23 8 0 Miscellaneous Information 25 ...

Page 5: ...t Setup Photo Radiated Emission radiated photos pdf Test Report Bandwidth Plot bw pdf External Photo External Photo external photos pdf Internal Photo Internal Photo internal photos pdf Block Diagram Block Diagram block pdf Schematics Circuit Diagram circuit pdf ID Label Location Label Artwork and Location label pdf User Manual User Manual manual pdf Cover Letter Confidentiality Request request pd...

Page 6: ...INTERTEK TESTING SERVICES FCC ID AAO120495 1 EXHIBIT 1 GENERAL DESCRIPTION ...

Page 7: ... for the clear channel to eliminate interference from broadcast radio channels that are used The transmitting frequency covers the complete FM band from 88 1 to 107 9MHz in 0 2MHz step i e 88 1MHz 88 3MHz 88 5MHz and so on The transmitting frequency is shown on the LED panel There is three buttons on the right hand side of the unit press button M1 up or M2 down to scroll to the desired FM frequenc...

Page 8: ...en Area Test Sites only to determine worst case modes All Radiated tests were performed at an antenna to EUT distance of 3 meters unless stated otherwise in the Justification Section of this Application 1 4 Test Facility The open area test site and conducted measurement facility used to collect the radiated data is located at Garment Centre 576 Castle Peak Road Kowloon Hong Kong This test facility...

Page 9: ...INTERTEK TESTING SERVICES FCC ID AAO120495 4 EXHIBIT 2 SYSTEM TEST CONFIGURATION ...

Page 10: ...on was changed The step by step procedure for maximizing emissions led to the data reported in Exhibit 3 0 The rear of unit shall be flushed with the rear of the table The equipment under test EUT was configured for testing in a typical fashion as a customer would normally use it The EUT was placed on turntable which enabled the engineer to maximize emissions through its placement in the three ort...

Page 11: ...led by Intertek Testing Services Hong Kong Ltd 2 5 Measurement Uncertainty When determining the test conclusion the Measurement Uncertainty of test has been considered 2 6 Support Equipment List and Description iPod Video EW 2402 Provided by Intertek All the items listed under section 2 0 of this report are Confirmed by Ho Wai Kin Ben Senior Supervisor Intertek Testing Services Hong Kong Ltd Agent...

Page 12: ...INTERTEK TESTING SERVICES FCC ID AAO120495 7 EXHIBIT 3 EMISSION RESULTS ...

Page 13: ...D AAO120495 8 3 0 Emission Results Data is included worst case configuration the configuration which resulted in the highest emission levels A sample calculation configuration photographs and data tables of the emissions are included ...

Page 14: ...h peak detectors A sample calculation is included below FS RA AF CF AG PD AV where FS Field Strength in dBµV m RA Receiver Amplitude including preamplifier in dBµV CF Cable Attenuation Factor in dB AF Antenna Factor in dB AG Amplifier Gain in dB PD Pulse Desensitization in dB AV Average Factor in dB In the radiated emission table which follows the reading shown on the data table may reflect the pr...

Page 15: ...of 29dB is subtracted The pulse desensitization factor of the spectrum analyzer was 0dB and the resultant average factor was 10dB The net field strength for comparison to the appropriate emission limit is 32dBµV m This value in dBµV m was converted to its corresponding level in µV m RA 62 0dBµV AF 7 4dB CF 1 6dB AG 29 0dB PD 0dB AV 10dB FS 62 7 4 1 6 29 0 10 32dBµV m Level in µV m Common Antilogar...

Page 16: ...C ID AAO120495 11 3 2 Radiated Emission Configuration Photograph Worst Case Radiated Emission at 107 900MHz For electronic filing the worst case radiated emission configuration photograph is saved with filename radiated photos pdf ...

Page 17: ...a on the following page lists the significant emission frequencies the limit and the margin of compliance Numbers with a minus sign are below the limit Judgement Passed by 4 0dB margin TEST PERSONNEL Signature Terry C H Chan Compliance Engineer Typed Printed Name July 28 2008 Date ...

Page 18: ... 46 0 14 2 H 618 100 18 5 16 29 0 31 5 46 0 14 5 H 706 400 17 4 16 30 0 31 4 46 0 14 6 H 794 700 16 3 16 31 0 31 3 46 0 14 7 H 883 000 15 2 16 32 0 31 2 46 0 14 8 NOTES 1 Peak Detector Data unless otherwise stated 2 All measurements were made at 3 meters Harmonic emissions not detected at the 3 meter distances were measured at 0 3 meter and an inverse proportional extrapolation was performed to co...

Page 19: ... 46 0 13 5 H 688 100 19 4 16 29 0 32 4 46 0 13 6 H 786 400 17 3 16 31 0 32 3 46 0 13 7 H 884 700 16 0 16 32 0 32 0 46 0 14 0 H 983 000 14 8 16 33 0 31 8 54 0 22 2 NOTES 1 Peak Detector Data unless otherwise stated 2 All measurements were made at 3 meters Harmonic emissions not detected at the 3 meter distances were measured at 0 3 meter and an inverse proportional extrapolation was performed to co...

Page 20: ... 46 0 13 0 H 755 300 18 7 16 30 0 32 7 46 0 13 3 H 863 200 17 4 16 31 0 32 4 46 0 13 6 H 971 100 15 3 16 33 0 32 3 54 0 21 7 H 1079 000 38 9 33 26 1 32 0 54 0 22 0 NOTES 1 Peak Detector Data unless otherwise stated 2 All measurements were made at 3 meters Harmonic emissions not detected at the 3 meter distances were measured at 0 3 meter and an inverse proportional extrapolation was performed to c...

Page 21: ...INTERTEK TESTING SERVICES FCC ID AAO120495 16 EXHIBIT 4 EQUIPMENT PHOTOGRAPHS ...

Page 22: ...INTERTEK TESTING SERVICES FCC ID AAO120495 17 4 0 Equipment Photographs For electronic filing photographs of the tested EUT are saved with filename external photos pdf and internal photos pdf ...

Page 23: ...INTERTEK TESTING SERVICES FCC ID AAO120495 18 EXHIBIT 5 PRODUCT LABELLING ...

Page 24: ...INTERTEK TESTING SERVICES FCC ID AAO120495 19 5 0 Product Labelling For electronics filing the FCC ID label artwork and the label location are saved with filename label pdf ...

Page 25: ...INTERTEK TESTING SERVICES FCC ID AAO120495 20 EXHIBIT 6 TECHNICAL SPECIFICATIONS ...

Page 26: ...RTEK TESTING SERVICES FCC ID AAO120495 21 6 0 Technical Specifications For electronic filing the block diagram and schematic of the tested EUT are saved with filename block pdf and circuit pdf respectively ...

Page 27: ...INTERTEK TESTING SERVICES FCC ID AAO120495 22 EXHIBIT 7 INSTRUCTION MANUAL ...

Page 28: ...ID AAO120495 23 7 0 Instruction Manual For electronic filing a preliminary copy of the Instruction Manual is saved with filename manual pdf This manual will be provided to the end user with each unit sold leased in the United States ...

Page 29: ...INTERTEK TESTING SERVICES FCC ID AAO120495 24 EXHIBIT 8 MISCELLANEOUS INFORMATION ...

Page 30: ...INTERTEK TESTING SERVICES FCC ID AAO120495 25 8 0 Miscellaneous Information The miscellaneous information includes details of the measured bandwidth and the test procedure ...

Page 31: ...20495 26 8 1 Measured Bandwidth For electronic filing the plot on saved in bw pdf shows the fundamental emission which is applied iPod Video as audio input source in maximum volume From the plot it shows the emission is within 200kHz band ...

Page 32: ...INTERTEK TESTING SERVICES FCC ID AAO120495 27 8 2 Discussion of Pulse Desensitization Pulse desensitivity is not applicable for this device Since the transmitter transmits the RF signal continuously ...

Page 33: ...INTERTEK TESTING SERVICES FCC ID AAO120495 28 8 3 Calculation of Average Factor The average factor is not applicable for this device as the transmitted signal is a continuously signal ...

Page 34: ...n maximum emissions The EUT is adjusted through all three orthogonal axes to obtain maximum emission levels The antenna height and polarization are varied during the testing to search for maximum signal levels The height of the antenna is varied from one to four meters Detector function for radiated emissions is in peak mode Average readings when required are taken by measuring the duty cycle of t...

Page 35: ...lsed transmissions of short enough pulse duration warrant a greater bandwidth is selected according to the recommendations of Hewlett Packard Application Note 150 2 A discussion of whether pulse desensitivity is applicable to this unit is included in this report See Exhibit 8 2 Above 1000MHz a resolution bandwidth of 1MHz is used Transmitter measurements are normally conducted at a measurement dis...

Page 36: ...INTERTEK TESTING SERVICES FCC ID AAO120495 31 EXHIBIT 9 CONFIDENTIALITY REQUEST ...

Page 37: ...INTERTEK TESTING SERVICES FCC ID AAO120495 32 9 0 Confidentiality Request For electronic filing a confidentiality request is saved with filename request pdf ...