background image

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P

Smart Radon Gas Monitor

RADONEYE  +

Operation Manual

RD200P2

•Type : pulsed ion chamber

•First reliable data out : < 60min

•Data interval : 10min update (60min moving average)

•Sensitivity : 0.5cpm/pCi/l at 10pCi/l (30cph/pCi/l)

•Operating range : 10℃ ~ 40℃  (50°F ~ 100°F), RH < 80%

•Measurement range : 0.1 ~ 255 pCi/l (9,435 Bq/㎥)

 

* Environment reference value 4pCi/l (148 Bq/㎥) 

•Precision : < ±10% at 10pCi/l

•Accuracy : < ±10% (min. error <±0.5pCi/l ) at 10pCi/l

•Interval of measurement value saving : 60 minutes

•Storage capacity : 1 year

•Power consumption : DC12 ± 0.1V, 0.1A ( Use 12V DC adapter)

•Size : Φ80(mm) x 120(mm)

•Display : 0.96 inch OLED

•Data communication : Wi-Fi (internet), Bluetooth

•Weight : 520g

•Altitude : Up to 2000 m

•pollution degree  : 2

 * Radon Eye Plus 2 is a function upgraded version of Radon Eye Plus that enhances 

    Wi-Fi setup convenience by adding BLE communication to previous Radon Eye Plus 

    products.

 * In March 2019, the model name of RadonEye Plus2 changes from RD200P  to 

    RD200P2.      

Product Specifications

Descriptive labeling in accordance with Quality 
Management and Safety Control Act for Industrial Goods.

Instrument type: RD200P2
Instrument name : RA
Kind : For home(indoor) use

Material : ABS

Manufactured date : Indicated separately

Manufacturer : FTLab

* Only the manufacturer or agency will inspect and supply 

Country of manufacture : Republic of Korea
Questions : www.radonftlab.com

FTLAB  succeeded  in  developing  a  real-time  Radon 
sensor in 2015, and also succeeded in mass production 
in 2016, we launched RADON FTLAB.

 

COPYRIGHT (C)FTLAB Co., Ltd   ALL RIGHT RESREVED.

503ho, 8, 330beon-gil, 
Haebong-ro, Danwon-gu, 
Ansan-si, Gyeonggi-do, Korea

FCC ID : 2AC7Z-ESPWROOM02
FCC ID : QECGWBMD0X
FCC ID : 2ASCLRD200P

① BLE access : Indicates it is  connected with smartphone using BLE communication
② Shock detect sign : It appears when a shock or vibration from outside is sensed, and 

    the measurement stops at the time

③ Radon concentration : Measured value of Radon shown in 10 minute interval  
④ Unit of measure : Shown in pCi/l or Bq/㎥. Unit can be changed by smartphone app.
⑤ Information display : SN, peak value, 1/2/7 day and month average, measurement time, 

     pulse count per 10 minute measurement (present value/last value)

Name and function of each part

BLE Access

Shock detection

Radon concentration

Unit

Information

RadonFTLab

0.

81

 pCi/l 

SN : RD21705010123

Name and function of each part

Front

LED : Red LED flashes for 30 seconds when Radon value exceeds 

          reference value. 

          Green LED flashes when Wi-Fi connection is not normal.

Ventilation window

LCD : Information display window for Wi-Fi access, shock detection, 
          Radon concentration, etc.

Rear   

Power

12V DC

Radon ?

1. Radon is a colorless, odorless and tasteless radioactive gas. 

Radon, a gas originating from radium which is generated by the collapse of 

uranium in soil, is everywhere on earth. It penetrates indoors mainly from the 

ground or building materials. The gases  that cause sick house syndrome and 

other  noxious  gases  luckily  smell.  Urban  gas  and  LPG  were  deliberately 

smelled. However, radon does not smell nor can be seen. And no matter how 

many years have passed, it is constantly released from the wall, ceiling and 

floor.

2. Radon is 8 times heavier than air and is easily concentrated in the house. 

Radon has the half-life of 3.8 days and makes alpha decay. The alpha particle 

emitted from radon has the smallest penetration power among the radiation 

rays and can not penetrate even a single piece of paper, but its destructive 

power is so great that the cells are damaged if they are directly impacted by 

radon, even having a nickname of "silent murderer". This is why radon detec

-

tion sensor is absolutely needed in home. 

3. Radon gas causes lung cancer.

Three causes of modern female lung cancer are passive smoking, ultrafine 

particles and radon. When radon gas enters the lung through breathing, alpha 

particles released from radon damage the lung cells. Since once destroyed 

lung cells are not regenerated, prolonged exposure to high concentration of 

radon gas will increase the likelihood of lung cancer. Therefore, the United 

States Environmental Protection Agency(EPA) designated Radon as a must 

be managed hazardous gas for healthy life.

- Accurate measurement value of the average radon level can be obtained when 

   the house is empty for 1 or 2 days.   

- Reliable value can be obtained about 1 hour after start of the measurement.

- Radon concentration in the house is generally high at dawn and low at daytime, 

   so continuous measurement for more than 24 hours is necessary.

Precautions

•Please, Measure in an environment free from vibration.
•Shock or disassembly will cause the equipment to malfunction and will not 

    be included in the warranty. (the unit will display  “ERR” message)
•Abnormal data can be measured when using near a strong electromagnetic 

    radiation source such as high voltage transmission line, subway line, Wifi
        transmitter(1Meter  or  less),  microwave  oven(1M  or  less)    ('OVER' 

message) 

•Use only indoors. No waterproof.
•Use the provided DC 12V adapter.
•Continuous use in an environment with relative humidity of 80% or 

    higher is prohibited.   
•A warning message may be sent to the set mobile device when it is higher 
    than the set radon concentration.

•Proper operating temperature range is 10℃ ~ 40℃ (50°F ~ 100°F) 

•The warranty period is one year after purchase. 

<Radon concentration fluctuation graph>

Seasonal radon concentration

 Winter

Autumn

Summer

Spring 

Daily radon concentration

Day

Evening     Day

Dawn

Precautions when using

Example of proper installation

·  please, let the device where there is no ventilation 
  environment to check the area's usual radon status. 

Prohibited

·  Install at least 50cm apart from wall, window and floor.
·  In general, proper places to install are on desk, table 
   in the living room, or  on dining table in the kitchen.  

Caution

1. For accurate measurement, close windows and doors tightly.

2. When Ra  is connected to DC 12V adaptor, measurement 

    starts automatically. 

             

3. After the power is on, the wait time (10 minutes) is indicated by ‘- -’. 

   When wait time is over, the measured values are displayed from 

   10 minutes later.  Measurements are displayed in 10 minute interval, 

   and saved in 1 hour interval.

To start the device

RA

C_device

P_device

M

ea
sured va

lue

12h

2

4

h

36h

Actual value

1h

RadonFTLab

0.

81

 pCi/l 

SN : RD21705010123

Precautions before using App.

This is the User's Manual for controlling Ra  device made in 
Radon FTLab. Please refer to the detailed manual on the Radon FTLab 
website  (http://RadonFTLab.com)  for  the  equipment  and  PC  program 

manual.

• Since it is an application that operates on a Wi-Fi base, there may be 

    operational limitations.

• It works properly in Android 4.3 version or iOS 8.0 version or later 

• If the distance between the device and the smart device increases, 

the 

    connection may be lost. 

• In the 5G Internet environment, there are restrictions in the use of the 

    product, so please use 2.4G.

• We recommend user to agree to the privacy policy during the app  

    setting stage for trouble-free data transfer.

• Bluetooth and GPS must be enabled before using

• The time in the area where the equipment is installed is applied to the

    data recorded after app setting/direct connection. The factory 

Bluetooth & GPS function of 

mobile device should be 

activated for 

Ra  setting

GPS

Bluetooth

RadonEye  +

Ra  is the world's first IoT smart radon detector that is used in connec

-

tion with web database based on WiFi. Therefore, Ra  is suitable for 

real-time radon monitoring and easy to create Real-Time Radon Map. Manufac-

turer,  Radon  FTLab  provides  web  database,  radon-net.com,  which  means  the 
user  can  access  the  data  every  time,  everywhere  by  smart  phone,  tablet  or 
internet connected desktop PC.

 The sensitivity performance of Ra is like a standard instrument. It is 20 
times higher when it is compared with other general customer’s radon detector, 

so the measurement data is fast and precise. Radon measurement data can be 
recorded within 1 hour with below 

±

10% error from starting time of measurement 

and the data will be updated every 10 minutes so the user will get to know the 

diminishing trend of indoor radon level just within 30 minutes by ventilation or 
window open.  

Ra has added temperature & humidity sensor and measurement time 

recording and extended the measurement range to 255pCi / l. 

Ra  offers free web uploading service at least 2 years.   

Measurement

Range

Precision

Accuracy

Data log

Display

Mobile control

Sensing factor

Time chec

k

ing

Web access

Mobile notification

Wi

Fi, Bluetooth

Radon

,

 

H

umidity

,

 Temperature

O

O

O

0.1

~

255 pCi/l

(1 

~

 

9,4

35 

Bq/㎥)

Model

RadonEye (RD200)

Ra  (RD200P2)

B

luetooth

Radon 

X

X

X

0.1

~

100 pCi/l

(1 

~

 3

,7

00 

Bq/㎥)

 < ±10

%

 at 10pCi/l (3

7

0

Bq/㎥)

 < ±10

%

 (min. error <±0.5pCi/l)

ma

x

 1year(1hour interval)

0.

9

6 inch O

L

ED

< RadonEye VS Ra  >

1. What should I do under condition of no Wi-Fi around available? 

A : RadonEye Plus2 automatically starts measuring when power is simply connected, so all you need to do is just select 'Connected Devices' 
menu in your smartphone application even if you don't have a Wi-Fi

2. Tell me how to set up an app. when errors. 

2.1. RadonEye Plus2 you are trying to set is not on the list. 

  

A (iPhone) : Switch Bluetooth off and on to update the list again. 
A (Android) : Click the "Rescan" button to update the list again.   

2.2. The Wi-Fi list displayed on the app. does not contain the desired Wi-Fi I’d like to connect to.

A : Click the ‘refresh’ icon to update the Wi-Fi list. for your reference, 5GHz Wi-Fi is not supported and will not appear in the list.

 

2.3. If 'Wi-Fi settings failed' is displayed when next button is clicked after entering the Wi-Fi information.

A : If the green LED on RadonEye Plus2 keeps blinking and Wi-Fi connection is not successful, please check if Wi-Fi password is entered 

correctly and internet connection status of the Router.

2.4. If the message 'RadonEye Plus2  registration failed' is displayed when the button is clicked after entering the Wi-Fi information, 

A : Smartphone should also be Internet-connected through Wi-Fi / LTE / 3G
Check the Internet connection status of the smart device and proceed with setting under this circumstance.

2.5. If other cases of setting failure

A : Check the Wi-Fi and GPS connection on your smartphone, then turn the device off and on and run.

3. How can I change RadonEye Plus2 wifi connection that’s been already set into previous wifi place?

A : If you have Wi-Fi in your environment, you can set it up again and use it easily by clicking ‘Main’-‘Sub Menu’-‘Network’

4. It continues to show the high concentration figure, Is it out of order?

A : In this case, leave it in a well ventilated location for about two days and try to measure the low concentration at veranda, indoor air quality, 
and high concentration in sequence

Q&A

RADON NET

Ra  provides Remote Radon Monitoring Network Service. You can 

check radon value in the web browser by registering the registration key which 

is given when you access the radon-net.com website when setting the app. 

You can also check the local radon value at any time through Radon Map. 

· My Devices

· Information

· Device Location

· Device Log (Graph)

· Radon Map

Sign In

Guest

Email

RADON NET

Password

Good
Normal
Warning
Bad

2

2

2

2  

2

2

2

2

2

2

2

2

2

2

2

2

2

2

2

      

2

Summary of Contents for RadonEye Plus 2

Page 1: ...FCC ID 2AC7Z ESPWROOM02 FCC ID QECGWBMD0X FCC ID 2ASCLRD200P Smart Radon Gas Monitor RADONEYE Operation Manual RD200P2 2 2 ...

Page 2: ...display SN peak value 1 2 7 day and month average measurement tim pulse count per 10 minute measurement present value last value Name and function of each part BLE Access Shock detection Radon concentration Unit Information RadonFTLab 0 81pCi l SN RD21705010123 Name and function of each part Front LED Red LED flashes for 30 seconds when Radon value exceeds reference value Green LED flashes when Wi...

Page 3: ...ecorded within 1 hour with below 10 error from starting time of measurement and the data will be updated every 10 minutes so the user will get to know the diminishing trend of indoor radon level just within 30 minutes by ventilation or window open RadonEye has added temperature humidity sensor and measurement time recording and extended the measurement range to 255pCi l RadonEye offers free web up...

Page 4: ...evice where there is no ventilation environment to check the area s usual radon status Prohibited Install at least 50cm apart from wall window and floor In general proper places to install are on desk table in the living room or on dining table in the kitchen Caution 2 2 ...

Page 5: ... the power is on the wait time 10 minutes is indicated by When wait time is over the measured values are displayed from 10 minutes later Measurements are displayed in 10 minute interval and saved in 1 hour interval To start the device RADONEYE C_device P_device Measured value 12h 24h 36h Actual value 1h RadonFTLab 0 81pCi l SN RD21705010123 2 2 2 ...

Page 6: ... later If the distance between the device and the smart device increases the connection may be lost In the 5G Internet environment there are restrictions in the use of the product so please use 2 4G We recommend user to agree to the privacy policy during the app setting stage for trouble free data transfer Bluetooth and GPS must be enabled before using The time in the area where the equipment is i...

Page 7: ... radon value select Users who do not agree the agreement can t use Radon Monitoring Network Service If the WiFi connection is not possible the equipment data can be directly managed by communication with BLE Setting Installed Location and Number Device Name Enter directly within 20 characters In case of push alarm it is shown as the set information Device Name Wi Fi Setting Wi Fi to be connected t...

Page 8: ...the set time everyday Warning Enable When measured value is higher than the set value Alarm message is sent To Use Cloud Real time data can be checked remotely without connecting RadonEye Delete To delete selected device from the list Do you want to delete the selected device from the list DEVICE CONNECTION 2 Sub menu Setting in App Main Menu RadonEye AI Speaker Radon Net Log in File Load What is ...

Page 9: ...alues When checking the whole data Detailed analysis is possible through MORE DATA in the upper right corner Clear button To initialize the data saved in RadonEye device Data Reload button To retrieve the data saved in RadonEye device Possible to output in pCi l or Bq values through Radio button Zoom In Zoom Out are possible Possible to set display period using buttons in the bottom Sava As button...

Page 10: ...R message Abnormal data can be measured when using near a strong electromagnetic radiation source such as high voltage transmission line subway line Wifi transmitter 1Meter or less microwave oven 1M or less OVER message Use only indoors No waterproof Use the provided DC 12V adapter Continuous use in an environment with relative humidity of 80 or higher is prohibited A warning message may be sent t...

Page 11: ...article emitted from radon has the smallest penetration power among the radiation rays and can not penetrate even a single piece of paper but its destructive power is so great that the cells are damaged if they are directly impacted by radon even having a nickname of silent murderer This is why radon detec tion sensor is absolutely needed in home 3 Radon gas causes lung cancer Three causes of mode...

Page 12: ...by registering the registration key which is given when you access the radon net com website when setting the app You can also check the local radon value at any time through Radon Map My Devices Information Device Location Device Log Graph Radon Map Sign In Guest Email RADON NET Password Good Normal Warning Bad 2 ...

Page 13: ... keeps blinking and Wi Fi connection is not successful please check if Wi Fi password is entered correctly and internet connection status of the Router 2 4 If the message RadonEye Plus2 registration failed is displayed when the button is clicked after entering the Wi Fi information A Smartphone should also be Internet connected through Wi Fi LTE 3G Check the Internet connection status of the smart...

Page 14: ...nhances Wi Fi setup convenience by adding BLE communication to previous Radon Eye Plus products In March 2019 the model name of RadonEye Plus2 changes from RD200P to RD200P2 Product Specifications Descriptive labeling in accordance with Quality Management and Safety Control Act for Industrial Goods Instrument type RD200P2 Instrument name RADONEYE Kind For home indoor use Material ABS Manufactured ...

Reviews: