Summary of Contents for AIRMASTER ULTRA

Page 1: ...Rainsoft Division of Aquion Inc 2080 East Lunt Avenue Elk Grove Village Illinois 60007 1 847 437 9400 or 1 800 860 7638 www rainsoft com REV 091012 LIT1002...

Page 2: ...ion or any other claims or torts Some states do not allow the exclusion or limitation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This war...

Page 3: ...Airmaster Ultra Installation 5 Choosing the Appropriate Sensitivity 6 Setting the Appropriate Sensitivity 6 Adjusting the Ozone Output Level 7 Maintenance Requirements 8 Airmaster Ultra Parts List 9 S...

Page 4: ...present in your home To receive optimal benefit and performance from the unit your furnace or air conditioner fan should be in the ON position at all times IMPORTANT SAFETY INSTRUCTIONS Always make s...

Page 5: ...as oils from your hands can create hot spots which reduce the lamp life In case of contact with the lamp wipe the lamp clean with a soft cloth dampened with rubbing alcohol 4 Check the parts list bel...

Page 6: ...loop in the power cord between the wire tie and the main power jack Then draw the wire tie tight around the power cord Note Cut off any excess of the wire tie with side cutters Do not cut the power co...

Page 7: ...1 minute of the heating cooling system turning Off the sensitivity setting should be lowered one step If the heating cooling system is Off and the sensitivity setting has been moved all the way to low...

Page 8: ...d and high LOW Use in an average sized home with no pets no tobacco smoke odors and minimum household odors MEDIUM Use in an average sized home with pets confined tobacco smoke odors and minimum house...

Page 9: ...t metal screws the cover the two screws and plug the transformer into the wall outlet REPLACING THE LAMPS Recommended every 24 months NOTE Use only RainSoft approved lamps for replacement Standard off...

Page 10: ...ter Ultra Flow Sensor 65061 6 AirMaster Ultra Ballast Board 65062 7 AirMaster Ultra Transformer 65000 8 AirMaster Ultra Display Board 65063 9 AirMaster Ultra Ribbon Cable 65064 SPECIFICATIONS Ozone La...

Page 11: ...board If fuse is blown replace Item 4 Page 9 Check the power light If light is still not On replace the ballast Item 7 Page 9 Ozone lamp does not turn Increase the sensitivity as described on page 6...

Page 12: ...living area is an extreme hazard potentially causing damage to the eyes of anyone who is exposed to the UV light especially small children If the AirMaster is installed near a register it must be inst...

Page 13: ...rea 2 Place template on the ductwork of the HVAC system Trace hole pattern and mark the four mounting holes on ductwork 3 Cut out the traced hole opening on ductwork with tin snips 4 Attach unit to ai...

Page 14: ......

Page 15: ...unit should be mounted lengthwise on the duct 2 Using a 2 hole saw drill holes at centers as indicated 3 Mark the four mounting holes on ductwork Attach the unit to ductwork using the four self tappi...

Page 16: ......