background image

I

J

H

L

M

H

I

N

O

P

G

F

SO75 GEAR DRIVEN SPRINKLER
SETTING INSTRUCTIONS

NOTE:

The

SO75

is factory preset with a 180° arc setting, and includes a

pre-installed #3 nozzle.

CHANGING A NOZZLE

1. REMOVING THE NOZZLE RETENTION SCREW

Use the hex

(E)

end of the universal tool

(A)

to remove the nozzle retention

screw

(I)

by turning counter-clockwise to remove or clockwise to re-install.

2. PULL UP THE RISER

Insert the pull up key

(D)

end of the universal tool

(A)

in the keyhole on the top

of the nozzle turret

(K)

and turn the key 1/4 turn to insure that the key does not

slip out of the keyhole when you pull it up. Firmly pull up the entire spring-loaded

riser to access the nozzle socket

(J)

. Hold the riser assembly with one hand.

3. REMOVING THE NOZZLE

With nozzle retention screw removed, the nozzle may be removed by either

turning on the water (wear safety glasses when using this method), or by

pulling outward on the nozzle prongs

(G)

with a pair of needle-nose pliers.

4. INSTALLING A NOZZLE

Press the desired nozzle

(F)

into the nozzle socket

(J)

. Make sure the nozzle

number is visible and the nozzle prongs

(G)

are up. Then, re-install the

nozzle retention screw

(I)

.

NOTE:

The nozzle retention screw is also a break-up

screw and used to adjust the distance of the spray.

SETTING THE ARC ADJUSTMENT

NOTE:

The

SO75 Gear Driven Sprinkler

has a fixed right start and an

adjustable left stop.

1. POSITIONING NOZZLE TURRET TO ITS “RIGHT START”

Place your finger on the top center of the nozzle turret

(K)

. Rotate the turret

counter-clockwise to the left stop to complete any interrupted rotation cycle.

Rotate the nozzle turret clockwise to the right start. This is the fixed side of the

arc. The nozzle turret must be held in this position for arc adjustments. The

right start does not change.

2. ADJUSTING THE RIGHT (FIXED) SIDE OF ARC

If the right side of the arc is not properly aligned, the sprinkler may spray in

areas not intended for watering such as driveways or adjacent properties. The

right side arc can easily be realigned.

OPTION 1: REPOSITION CAN ON THE FITTING

Turn the sprinkler can and the fitting below it left or right to the desired

position. This may require temporary removal of the soil around the sprinkler

to allow you to grip the housing can

(M)

.

OPTION 2: REMOVE INTERNAL RISER ASSEMBLY AND REPOSITION

Unscrew the top counter-clockwise and remove the internal sprinkler assembly

(L)

from the can. Once removed with nozzle turret

(K)

at its right start,

reposition the riser assembly so that nozzle arrow points to the desired start

position. Replace the riser assembly back in the can and screw on the top. At

this point you have realigned the right arc stop, and you can adjust the left arc

to an appropriate setting.

3. ADJUSTING THE LEFT (VARIABLE) SIDE OF THE ARC

INCREASING THE ARC

Insert the arc adjustment key

(C)

end of the universal tool

(A)

into the arc set

adjustment slot

(P)

. While holding the nozzle turret

(K)

at the right start, turn

the universal tool clockwise. Each full 360° turn of the universal tool will increase

the arc 90°. Adjust to any arc between 40° and 360°. The universal tool will

stop turning, or there will be ratcheting noise, when the maximum arc of 360°

has been reached.

DECREASING THE ARC

Insert the arc adjustment key

(C)

end of the universal tool

(A)

into the arc set

adjustment slot

(P)

. While holding the nozzle turret

(K)

at the right start, turn

the universal tool counter-clockwise. Each full 360° turn of the universal tool

will decrease the arc 90°. Adjust to any arc between 40° and 360°. The universal

tool will stop turning, or there will be a ratcheting noise, when the minimum

arc of 40° has been reached.

SPRINKLER INSTALLATION

1. INSTALL AND BURY

Do not use pipe dope. Thread the sprinkler on the pipe. Bury the sprinkler

flush to grade.

NOTE:

Gear driven sprinklers and pop-up sprays should not

be installed on the same watering zone.

2. INSPECTING THE FILTER

Unscrew the top and lift the complete sprinkler assembly

(L)

out of the housing

can

(M)

. The filter is located on the bottom of the sprinkler assembly and can

be easily pulled out, cleaned and re-installed.

3. WINTERIZATION TIPS

When using an air compressor to remove water from the system please note

the following:

a.

Do not exceed 30 PSI.

b.

Always introduce air into the system gradually to avoid air pressure surges.

Sudden release of compressed air into the sprinkler can cause damage.

c.

Each zone should run no longer than 1 minute on air. Sprinklers turn 10 to

12 times faster on air than on water. Over spinning rotors on air can cause

damage to the internal components.

C

B

D

E

F

A

Universal Tool

B

Flat Blade

Screwdriver

C

Arc

Adjustment

Key

Pull Up Key

E

Hex Key

H

Key in Keyhole

H

Key in Keyhole

I

Nozzle

Retention

Screw

J

Nozzle

Socket

K

Nozzle

Turret

L

Internal

Sprinkler

Assembly

M

Housing

Can

D

G

Nozzle Prongs

F

Nozzle

STANDARD NOZZLE PERFORMANCE

Pressure   Radius        Flow

KPa

Bars Meters        L/M      M

3

/H

206

2.1

11.0

7.6

0.45

275

2.8

11.6

9.1

0.55

344

3.4

12.2

10.2

0.61

413

4.1

12.2

11.0

0.66

206

2.1

8.5

1.9

0.11

275

2.8

8.8

2.3

0.14

344

3.4

8.8

2.7

0.16

413

4.1

9.1

3.0

0.18

206

2.1

8.8

2.6

0.16

275

2.8

9.1

3.0

0.18

344

3.4

9.1

3.4

0.20

413

4.1

9.4

3.8

0.23

206

2.1

9.1

3.4

0.20

275

2.8

9.4

3.8

0.23

344

3.4

9.4

4.5

0.27

413

4.1

9.8

4.9

0.30

206

2.1

9.8

4.5

0.27

275

2.8

10.1

5.3

0.32

344

3.4

10.4

6.1

0.36

413

4.1

10.4

6.8

0.41

206

2.1

11.0

9.8

0.59

275

2.8

12.2

11.4

0.68

344

3.4

12.8

12.9

0.77

413

4.1

12.8

14.0

0.84

206

2.1

11.6

15.9

0.91

275

2.8

13.1

18.5

1.11

344

3.4

14.0

20.8

1.25

413

4.1

14.3

22.7

1.36

275

2.8

13.7

22.7

1.36

344

3.4

14.6

25.7

1.54

413

4.1

14.9

28.8

1.73

482

4.8

15.5

31.0

1.86

Nozzle

#3

#0.5

#0.75

#1

#2

#4

#6

#8

Data represents test results in zero wind for the
SO75 Rotor. Adjust for local conditions. Radius
may be reduced with nozzle retention screw.

LOW ANGLE NOZZLE PERFORMANCE

Pressure   Radius        Flow

KPa

Bars Meters        L/M      M

3

/H

207

2.0

6.7

4.5

.34

275

3.0

7.3

6.4

.39

344

3.5

7.9

6.8

.41

413

4.0

8.5

7.6

.46

207

2.0

8.8

11.4

.68

275

3.0

9.8

11.7

.71

344

3.5

10.7

13.2

.80

413

4.0

11.3

14.4

.87

207

2.0

9.4

12.9

.78

275

3.0

10.4

14.8

.89

344

3.5

11.3

16.7

1.00

413

4.0

11.6

17.8

1.07

275

3.0

11.6

24.6

1.68

344

3.5

12.2

27.6

1.66

413

4.0

12.8

30.3

1.82

482

5.0

13.4

32.6

1.96

Nozzle

#1

#3

#4

#6

Nozzle Turret Top

O

Keyhole

P

Arc Set

Adjustment

I

Nozzle

Retention

Screw

RAIN SpA

via Kennedy 38/40
20023 Cerro Maggiore (MI)
Italy
TEL. +39 0331 514511
FAX. +39 0331 421375
www.rain.it
info@rain.it

L-16005113

Left

Stop

Right

Start

ENGLISH

Reviews: