background image

ENGLISH

 

RAIS ­ manual for Rais 700

 

INSTRUCTIONS FOR INSTALLATION, 

USE AND MAINTENANCE 

RAIS 700 

IMPORTANT INFORMATION 

On first lighting the stove you must be careful not to touch the painted 

surfaces and it is MOST IMPORTANT that the door is kept slightly ‘ajar’ in 

order for the door seal and sealant to cure. 

This will prevent the door seal sticking to the painted body and becoming 

damaged.

Summary of Contents for 700

Page 1: ...IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal and seal...

Page 2: ...ENGLISH RAIS manual for Rais 700 2...

Page 3: ...TION AIR SUPPLY 14 INSTALLATION 14 15 INSTALLATION DISTANCE 16 21 COMMISSIONING AND HANDOVER 21 OPERATING INSTRUCTIONS FUEL 22 23 REGULATION OF COMBUSTION AIR 23 USING THE WOOD BURNING STOVE 24 ADJUST...

Page 4: ...therefore recommend that you note down the number in the table below The production number is located in the top of the convection box WARRANTY Your Rais wood burning stove comes with a 5 year warran...

Page 5: ...80 2 6 8 5 1 268 Fuelling should be undertaken within 3 hours ca 60 105 1 8 12 125 RAIS 700 Rais 700 Nominal output kW 5 2 Min Max output kW 3 7 Heating area m2 Ca 60 105 Size width depth height mm 82...

Page 6: ...tallation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during the insta...

Page 7: ...ficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an existing c...

Page 8: ...for the permanent air supply into the room in which the stove is fitted in accordance with Approved Document J see also combustion air supply Adequate provision e g easily accessible soot door or doo...

Page 9: ...ENGLISH RAIS manual for Rais 700 9 Flue Outlet Positions...

Page 10: ...Document J The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to the hearth should comply with the guidance on the separation of combustible mat...

Page 11: ...ENGLISH RAIS manual for Rais 700 11...

Page 12: ...ENGLISH RAIS manual for Rais 700 12...

Page 13: ...or Rais 700 13 Ventilation make the best possible use of the inserts The stove is equipped with four convection air outlets which can be connected with suitable air ducts to other rooms Note this is N...

Page 14: ...may be connected with suit able air ducts to other rooms Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion air of soli...

Page 15: ...tove is perfectly level and make adjustments using the levelling bolts in the base Remove the frame and door from the stove Be careful not to damage the glass or paint Seal the flue pipe on to the flu...

Page 16: ...ENGLISH RAIS manual for Rais 700 16 Insulation ability such as Aqua panel coefficient of thermal conductivity 0 36 W mk or better Please use metal stud Insulate ceiling if necessary...

Page 17: ...ENGLISH RAIS manual for Rais 700 17 Insulate ceiling if necessary...

Page 18: ...ENGLISH RAIS manual for Rais 700 18 Distance to non combustible material 50mm min Distance to non combustible material 50mm min Insulate ceiling if necessary...

Page 19: ...ENGLISH RAIS manual for Rais 700 19...

Page 20: ...ENGLISH RAIS manual for Rais 700 20...

Page 21: ...mmissioning and handover Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry out bef...

Page 22: ...combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsuitable for...

Page 23: ...lass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the top of the combustion chamber towards the back serves to combust the final gas residues By settin...

Page 24: ...ire so that the wood burning stove can get accustomed to the high temperature This gives the best start and any damage is avoided Be aware that a strange but harmless odour and smoke concoction may em...

Page 25: ...e emission does persist the following immediate actions should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blo...

Page 26: ...wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a screwed up piece of newspaper between the upper baffle plate and the chimney Light the paper and wa...

Page 27: ...bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when the f...

Page 28: ...unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensation and su...

Page 29: ...arefully Lift the baffle plate a little and push towards one of the sides Remove the baffle plate by lifting it upwards and tilting on it s end Gently take out the baffle plate Now there is a clear vi...

Page 30: ...A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke channels leaking chimney leakage between chimney and flue If your stove co...

Page 31: ...insulate the chimney Use a qualified installer HETAS or building control Spend time with your stove get to know how your stove and chimney works Don ts Overload your stove with wood Overfire allow yo...

Page 32: ...Special adaptor Spare parts are available to order from your Rais dealer stockist 7091401SORT Complete cover 7092090 Steel door 7091090 Glass door 7092200 Fire brick set 7090990 Air damper 7090101MON...

Page 33: ...ENGLISH RAIS manual for Rais 700 33...

Page 34: ...GLISH RAIS manual for Rais 700 34 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk June 20...

Reviews: