background image

BRUGERVEJLEDNING

BEDIENUNGSANLEITUNG

USER MANUAL

MANUEL D’UTILISATEUR

BRUKERVEILEDNING

BRUKSANVISNING

KÄYTTÖOHJE

GEBRUIKERHANDLEIDING

600 MAX

600 MAX/E

POSITIV

OUTLINE

NEGATIV

Summary of Contents for attika 600 MAX-1

Page 1: ...BRUGERVEJLEDNING BEDIENUNGSANLEITUNG USER MANUAL MANUEL D UTILISATEUR BRUKERVEILEDNING BRUKSANVISNING KÄYTTÖOHJE GEBRUIKERHANDLEIDING 600 MAX 600 MAX E OSITIV UTLINE EGATIV ...

Page 2: ...t Drawing name INDUSTRIVEJ 20 9900 FREDERIKSHAVN DENMARK Phone 45 98 47 90 33 Fax 45 98 47 92 91 E mail info rais dk Homepage www rais dk Corrections D M Y pch 600MAX Heat storage 21 11 2019 A3 11 0801 8603 07 09 2020 GB The production number can be found inside the drawer compartment ...

Page 3: ...g the handle 14 Removing the combustion chamber lining 15 External air connection Air System 16 Lubricating hinges 18 Fitting the smoke outlet spigot 19 Fitting the top box 20 Fitting the top plate 21 Test certificate 22 Assessment of Performance AOP 24 This manual applies to the following models 600 MAX 1 Front 600 MAX 2 Right 600 MAX 3 Left 600 MAX 4 Three sided 600 MAX E 1 Front 600 MAX E 2 Rig...

Page 4: ...ibution plate Seek advice from a building ex pert If the wood burning stove is to be in stalled on a flammable floor national and local regulations must be complied with including for the size of the non flamma ble plate which must cover the floor in front of the wood burning stove to pro tect the floor from any embers that fall out of the stove The fireplace insert must be positioned at a safe di...

Page 5: ...idth depth height mm 688 X 440 X 1305 688 X 440 X 1305 Combustion chamber W x D x H mm 544 X 255 X 165 544 X 255 X 165 Min uptake pascal 12 12 Weight kg min depending on the model 223 246 Efficiency 76 81 CO emission attributed to 13 O2 0 0915 1144 mg Nm 0 0927 1159 mg Nm NOx emission attributed to 13 O2 mg Nm 69 76 Particle emission in accordance with NS3058 3059 g kg 2 11 2 11 Dust measurement i...

Page 6: ...A A B B A A B B 688 221 n 1 6 0 438 560 264 5 437 600 MAX 4 Glass 11 0000 6567 341 152 n 9 8 5 1306 1203 115 n 1 3 5 n 1 6 0 79 n 1 1 0 682 440 434 1123 DIMENSIONAL SKETCHES GB ...

Page 7: ...6 A A B B A A B B 221 n 1 6 0 600 MAX 4 Classic 11 0000 6568 688 438 560 437 264 5 n 1 1 0 79 1306 115 1203 n 1 6 0 n 1 3 5 440 434 682 n 9 8 5 152 341 1123 DIMENSIONAL SKETCHES GB ...

Page 8: ...ed Follow the installation and operating instruction manual Intermittent operation F Veuillez lire et observer les instructions du mode d emploi Foyer à durèe de combustion limitèe homologué pour cheminée à connexions multiples Utiliser seulement les combustibles recommandés Hergestellt für Produced for ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham RAIS A S Industrivej 20 DK 9900 Frederikshavn STØV ST...

Page 9: ...til røggassamleledning og intervalfyring DE Lesen und befolgen Sie die Bedienungsanleitung Zeitbrandfeuerstätte Nur empfohlene Brennstoffe einsetzen UK Fuel types only recommended Follow the installation and operating instruction manual Intermittent operation F Veuillez lire et observer les instructions du mode d emploi Foyer à durèe de combustion limitèe homologué pour cheminée à connexions multi...

Page 10: ...wo polystyrene blocks 1 which protect the combustion chamber lining in transit These must be removed before starting a fire in the stove The glass is not recyclable The glass must be disposed of along with any resid ual ceramic or porcelain waste Heat resistant glass has a higher melting point which is why it is not recyclable By ensuring heat resistant glass does not end up alongside recyclable p...

Page 11: ...ges only apply to the wood burning stove The final choice of Chimney solution may have a larger safety distance to the flammable material The Chimney solution must always be installed in accordance with current building regulations and in a manner that en sures CE marking compliance INSTALLATION DISTANCES GB ...

Page 12: ...FLAMMABLE MATERIAL 600MAX 600MAX E Three sided The installation distances applicable to the wood burning stove are shown below Bear in mind that the final choice of chimney may have a different safety distance If the floor is flammable we recommend placing the stove on a non flammable surface All dimensions are in mm Right angle installation Corner installation GB ...

Page 13: ...12 50 500 1100 321 447 1 1 0 0 770 INSTALLATION DISTANCES Flammable ceiling Safety distances to the flammable ceiling and floor are measured from above and below the door GB ...

Page 14: ...13 1 HEIGHT ADJUSTMENT HEIGHT ADJUSTMENT The stove is equipped with four adjustment screws 1 under the stove Use the adjustment screws to ensure the wood burning stove stands level GB ...

Page 15: ...3 2 3 2 FITTING CHANGING THE HANDLE The wood burning stove comes with a tem porary handle 1 To remove it undo the screws 2 The new handle 3 can now be fitted to the stove using the screws 2 FITTING THE HANDLE GB ...

Page 16: ...mber lining 1 Remove the flue panel 1 by pushing the front up and pulling forward so that the rear end becomes free of the vertical panels The flue panel can now be carefully removed 2 Remove the base panels 2 3 Loosen the side panels 3 by turning the end of the panel in towards the fireplace s centre Next carefully remove them 4 Remove the rear panels 4 by removing the lock in the top of the pane...

Page 17: ...cure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the base plate using the double sided adhesive gasket 7 and fit the flexible hose 3 on the valve 6 with the hose clamp 2 Air System Fresh air supplied through the floor 1 Spigot 2 Hose clamp 3 Flexible hose 4 M5 screw 5 3 mm Unbrako key 6 Valve 7 Double sided ...

Page 18: ...ve the cover on the rear of the stove and secure the flexible hose 3 on the spigot 1 using the hose clamp 2 Fit the spigot on the stove with the four M5 screws 4 Secure the valve 6 on the wall using suitable fixtures with the gasket 7 between the wall and valve Fit the flexible hose 3 on the valve 6 using the hose clamp 2 The cover 8 goes over the flexible hose behind the stove Cover GB ...

Page 19: ...18 LUBRICATING THE HINGES LUBRICATING THE HINGES LOCK The fireplace must be lubricated regularly using the four moving parts on the lock and hinges see image Use heat resistant oil GB ...

Page 20: ...SMOKE OUTLET SPIGOT THE SMOKE OUTLET SPIGOT CAN BE TURNED TWO WAYS YOU CAN CHOOSE EITHER WAY Version A uses the three free holes 1 Ø8 Slits 2 M6 Nuts 3 M6 Washers 4 M6X20mm cylinder screws Version B uses the three threaded holes 5 M6 threaded holes 6 M6X20mm cylinder screws GB ...

Page 21: ... top box place it on the stove and insert the four M5x20mm spacers one in every corner After positioning the top box adjust the intermediary space to 5 mm then tighten the top box with the four M5x10 cylinder screws 1 M5X20mm Spacers 2 M5X10mm cylinder screws GB ...

Page 22: ...in position and insert the four M5x8 spacers supplied one in every corner Once the top plate is lowered in place over the spacers all four bushings below the top plate must fit over the spacers Adjust the intermediary space to 5 mm by adjusting the spacers 1 M5X8mm Spacer GB ...

Page 23: ...2 Virkningsgrad 76 Røggastemperatur 306 C Afstand til bagvæg se opstillingsvejledning Afstand til sidevæg se opstillingsvejledning Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058 2 11 g kg tørstof middelværdi krav 4 Partikler efter NS 3058 2 84 g kg tørstof maksimalt krav 8 OGC efter CEN TS 15883 54 mgC Nm ved 13 O2 krav 120 Støv efter EN 16510 1 5 mg Nm ved 13 O2 krav 30 Bemæ...

Page 24: ...tilling mod brandbar væg Afstand til sidevæg 500 mm normalopstilling mod brandbar væg Emissioner iht NS 3058 og eller CEN TS 15883 Partikler efter NS 3058 g kg tørstof middelværdi krav 4 Partikler efter NS 3058 g kg tørstof maksimalt krav 8 OGC efter CEN TS 15883 66 mgC Nm ved 13 O2 krav 120 Støv efter EN 16510 1 15 mg Nm ved 13 O2 krav 30 Bemærk venligst at de oplyste værdier er et uddrag af prøv...

Page 25: ...cluding units where relevant Energy efficiency 76 Emission of CO 0 09 Emission of OGC 54 mgC Nm3 Emission of NOx 69 mg Nm3 Emission of dust 5 mg Nm3 Test report s No s 300 ELAB 2431 EN covering Rais 600 Inset appliance A 4 9 Risk of fire Clearance to combustible Test report s No s 300 ELAB 2515 EN covering 600 MAX E free standing room heater This Assessment of Performance Report covers only the ab...

Page 26: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn Denmark www rais dk ATTIKA FEUER AG Brunnmatt 16 CH 6330 Cham Switzerland www attika ch POSITIV OUTLINE NEGATIV ...

Reviews: