Page 2: ... good ventilation and no direct exposure to strong light Keep the device clean and away from dust water and moist areas Do not place any object on the device to avoid damage due to overheating or compressional deformation When installing the device keep it away from heat or fire sources such as the electric heater and candle When installing the device keep it away from electric appliances with str...

Page 3: ...erwise the fiber may be damaged or optical signals may be blocked Do not stare into the optical interface or end face of the fiber to avoid eye injury 1 5 Other precautions If any abnormality occurs such as smoking abnormal sound and peculiar smell stop using the device immediately power it off pull out all cables from it and contact Raisecom technical support personnel Do not let any object such ...

Page 4: ...made in the preparation of this document to ensure accuracy of the contents but all statements information and recommendations in this document do not constitute the warranty of any kind express or implied Raisecom is not liable for any losses or damage caused by natural disasters beyond Raisecom s responsibilities such as earthquake and flood 3 Device specifications 3 1 Technical specifications T...

Page 5: ...rface Parameter PON signals Interface type SC APC Typical optical wavelength 1310 nm 1490 nm Tx optical power 0 5 5 dBm Rx optical power 28 to 8 dBm 3 2 Packing list Table 3 3 lists packing list of the ISCOM HT803G WS2 Table 3 3 Packing list Device Component Quantity ISCOM HT803G WS2 1 Power adapter 1 Ethernet cable 1 Telephone line 1 User manual 1 If any item mentioned above is missing contact th...

Page 6: ...6 4 LEDs ...

Page 7: ...7 5 Connection and usage 5 1 Interfaces and buttons The figure shown above is diagrammatic only The actual appearance is subject to the device provided by the SP ...

Page 8: ...te Record of Damage and Repair Signature of Repair man Signature of Customer Damage Reason Repair Measure Address East 11 Raisecom Building 10 Xi Bei Wang East Road Haidian District Beijing China Post Code 100094 Tel 86 10 82883305 www raisecom com ...

Page 9: ...mstances are not included in the warranty Products are misused or used in abnormal situations Damages that are attributable to improper installation disassembly or repairing by unauthorized parties Product serial number and the number on receipt are amended without permission Damages caused by natural disasters or human behaviors Product has been exceeded warranty period Damages that are attributa...

Page 10: ... WS2 on a wall as below Step 1 Choose a proper height of installation position so that you can easily observe LEDs and connect the power supply Step 2 Knock two cement nails with spacing of 155 mm distance between two wall mount holes into the wall The diameter of a cement nail should be smaller than that of the wall mount hole 8 mm Step 3 Align wall mount holes with knocked cement nails and hang ...

Page 11: ...or other problems 5 4 Powering on device Step 1 After the ISCOM HT803G WS2 is properly installed insert the power adapter plugs and connect them to the device and socket respectively Step 2 Press the ON OFF button If the Power LED is green it indicates that the ISCOM HT803G WS2 is powered on properly Step 3 After Power On Self Test POST and initialization the ISCOM HT803G WS2 enters working status...

Page 12: ...Open a browser Enter the IP address on the label for accessing the ISCOM HT803G WS2 at the LAN side and press Enter The Web login interface appears Step 5 Enter the correct user name and password on the label to access the ISCOM HT803G WS2 ...

Page 13: ...is 12 V Why is PON LED off Please check whether the fiber works properly Please check whether the fiber is connected properly Please check whether the fiber connector is clean Please check whether optical attenuation is normal Please check whether the SN or MAC address matches with the OLT Why is LOS LED blinking Please check whether the fiber connector is properly inserted into the correct interf...

Page 14: ...right click the My Computer icon and then choose Manage Click Device Manager on the left tree topology to check whether a device with or symbol is displayed under the Network adapters option If yes uninstall the device driver and re install the driver Or you can insert the NIC into another slot If the problem is not solved replace the NIC ...

Page 15: ...munications equipment applications exempted from the prohibition are shown below Lead in termination coatings of electrical and electronic components Lead in solders on printed circuit boards Lead in solders The product is compliant with RoHS Directive 2011 65 EU and subsequent revised RoHS directives including Exemptions as required below Lead in high melting temperature type solders i e lead bas...

Page 16: ...s For any assistance please contact our local office or company headquarters Website http www raisecom com Tel 8610 82883305 Fax 8610 82883056 Email export raisecom com Address Raisecom Building No 11 East Area No 10 Block East Xibeiwang Road Haidian District Beijing P R China Postal code 100094 ...